Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Schraubensicherungslack Fast Dry
- Product Code
- SSL FastDry
- Synonyms
- Schraubensicherungslack
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- P600-604V-S000-53DR
Identified Uses
Tamper proof varnish/sealant.
Uses advised against
Not to be used as glue/adhesive!
Manufacturers & Suppliers
Lackfabrik Bäder GmbH & Co. KG.
manufacturer
Dieselstraße 34, D-73734 Esslingen/Neckar
Emergency Contacts
Emergency Contact
+49 (0) 711/381607
Only available during office hours.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest. In case of irregular breathing or respiratory arrest provide artificial respiration.
Take off immediately all contaminated clothing. After contact with skin, wash immediately with plenty of water and soap. Do not use solvents or thinners.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Seek medical advice immediately.
If swallowed, rinse mouth with water (only if the person is conscious). Seek medical advice immediately. Keep victim calm. Do NOT induce vomiting.
Immediate Medical Attention
Seek medical advice immediately.
Medical Treatment
First Aid, decontamination, treatment of symptoms.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
alcohol resistant foam, carbon dioxide, Powder, spray mist, (water)
strong water jet
Dense black smoke occurs during fire. Inhaling hazardous decomposing products can cause serious health damage.
Cool closed containers that are near the source of the fire.
Firefighter Protection
Provide a conveniently located respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep away from sources of ignition. Ventilate affected area. Do not breathe vapours.
Do not allow to enter into surface water or drains.
collect it for disposal in appropriate containers in accordance with the local regulations (see section 13). Clean using cleansing agents. Do not use solvents.
Materials: cleansing agents
Related Products
Similar products with comparable safety profiles
Schnellreiniger
CAS: ---
Loctite Power Grab Heavy Duty Express
---
UHU plus schnellfest (Härter)
---
UHU plus sofortfest (Härter)
---
Klüberpaste 46 MR 401
---
Aerosol NC Industrielack uni glanz, diff colors
---
Aerosol NC Industrielack uni glanz, diff colors
---
Aerosol NC Industrielack uni glanz, diff colors
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid formation of flammable and explosive vapour concentrations in the air and exceeding the exposure limit values. Only use the material in places where open light, fire and other flammable sources can be kept away. Avoid contact with skin, eyes and clothes. Do not inhale dusts, particulates and spray mist when using this preparation. Avoid respiration of swarf.
When using do not eat, drink or smoke.
Keep away from heat sources, sparks and open flames. Use only spark proof tools.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide good ventilation. This can be achieved with local or room suction. If this should not be sufficient to keep aerosol and solvent vapour concentration below the exposure limit values, a suitable respiratory protection must be used.
For prolonged or repeated handling the following glove material must be used: NBR (Nitrile rubber) Thickness of the glove material > 0,4 mm; Breakthrough time: > 480 min. Unsuitable material: NR (natural rubber, Natural latex) Observe the instructions and details for use, storage, maintenance and replacement provided by the protective glove manufacturer. Penetration time of glove material depending on intensity and duration of exposure to skin. Recommended glove articles EN ISO 374
Wear closely fitting protective glasses in case of splashes.
If concentration of solvents is beyond the occupational exposure limit values, approved and suitable respiratory protection must be used. Use only respiratory protection equipment with CE-symbol including four digit test number.
Wear antistatic clothing of natural fibers (cotton) or heat resistant synthetic fibers.
Do not allow to enter into surface water or drains. See section 7. No additional measures necessary.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable when applying the recommended regulations for storage and handling. Further information on correct storage: refer to section 7.
No information available.
Keep away from strong acids, strong bases and strong oxidizing agents to avoid exothermic reactions.
Hazardous decomposition byproducts may form with exposure to high temperatures.
not applicable
Hazardous decomposition byproducts may form with exposure to high temperatures, e.g.: carbon dioxide, carbon monoxide, smoke, nitrogen oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Do not allow to enter into surface water or drains. This material and its container must be disposed of in a safe way. Waste disposal according to directive 2008/98/EC, covering waste and dangerous waste.
Do not allow to enter into surface water or drains. This material and its container must be disposed of in a safe way.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- PAINT RELATED MATERIAL
- Transport Class
- 3
- Packing Group
- III
Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8
Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8
Transport always in closed, upright and safe containers. Make sure that persons transporting the product know what to do in case of an accident or leakage. Advices on safe handling: see parts 6 - 8
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Schraubensicherungslack Fast Dry known by?
Schraubensicherungslack Fast Dry is also known as: Schraubensicherungslack
What is the hazard signal word for Schraubensicherungslack Fast Dry?
The signal word is danger.
What is the physical form of Schraubensicherungslack Fast Dry?
Schraubensicherungslack Fast Dry is a liquid with refer to label color. It has characteristic odor.
What is Schraubensicherungslack Fast Dry used for?
Tamper proof varnish/sealant.
What are the hazard statements for Schraubensicherungslack Fast Dry?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
What is the melting point of Schraubensicherungslack Fast Dry?
The melting point is not determined and the boiling point is 76 °C.