NextSDS Logo
As

Aspen 2

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aspen 2
Product Form
Mixture
Product Code
101001

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
SE49-H29X-JD96-S43E

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Fuel for 2-stroke motors.
Uses Advised Against
Other than stated above.

Overview

Aspen 2 is a clear. substance commonly used fuel for 2-stroke motors..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 1 H224
Skin Irr. Category 2 H315
STOT SE Category 3 H336
Asp. Tox. Category 1 H304
Aquatic Chronic Category 4 H413

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H224: Extremely flammable liquid and vapour.
  • H304: May be fatal if swallowed and enters airways.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H413: May cause long lasting harmful effects to aquatic life.

Precautionary Statements

  • P102: Keep out of reach of children.
  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P260: Do not breathe vapours.
  • P262: Do not get in eyes, on skin, or on clothing.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER, a doctor.
  • P331: Do NOT induce vomiting.
  • P501: Dispose of contents/container to approved waste recipient, in an open container.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Lantmnnen Aspen AB company logo - Safety Data Sheet supplier organization

Lantmnnen Aspen AB

manufacturer

๐Ÿ“

Iberovgen 2 SE-438 54 Hinds Sweden

๐ŸŒ

SE

๐ŸŒ www.aspen.se
Anglo American Oil Company Ltd company logo - Safety Data Sheet supplier organization

Anglo American Oil Company Ltd

distributor

๐Ÿ“

58 Holton Road, Holton Heath Trading Park BH16 6LT Poole United Kingdom

๐ŸŒ

GB

๐Ÿ“ž

+44 1929 551557

๐Ÿ“ 

+44 1929 551567

๐ŸŒ www.aaoil.co.uk

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+46 301 230000

๐ŸŒ

SE

๐Ÿ•’

08.00-16.30 CET

๐Ÿ’ก

For non-emergency personnel

National Poisons Information Service

๐Ÿ“ž

NHS 111

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Contains 2% by volume Synthetic motor oil, classified as non-hazardous according to CLP (EU).

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Alkylate
EC: 271-267-0
68527-27-5 78-93% โš ๏ธ Hazardous
Isomerate
EC: 265-073-5
64741-70-4 5-15% โš ๏ธ Hazardous
Isopentane
EC: 201-142-8
78-78-4 2.5% โš ๏ธ Hazardous
n-hexane
EC: 203-777-6
110-54-3 0.2% โš ๏ธ Hazardous

Additional Information

Note P: The classification as a carcinogen or mutagen need not apply if it can be shown that the substance contains less than 0,1 % w/w benzene (EINECS No 200-753-7). When the substance is not classified as a carcinogen at least the precautionary statements (P102-)P260-P262- P301 + P310-P331 (Table 3.1) or the S-phrases (2-)23-24-62 (Table 3.2) shall apply. This note applies only to certain complex oil-derived substances in Part 3. Full text of H- and EUH-statements: see section 16.

Composition Notes

Contains no other components which will influence the classification of the product. Ingredients' environmental classification is not supported by tests on the mixture. Mixture contains <3% butane (<0,1% butadiene). Toluene <0,1%, n-hexane <0,5%, aromatics <1%.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person to fresh air and keep comfortable for breathing. Obtain medical attention if breathing difficulty persists.

Symptoms:

May cause headache, nausea and irritation of respiratory tract. May result in aspiration into the lungs, causing chemical pneumonia.

๐Ÿ–๏ธ Skin Contact

Remove immediately contaminated clothing. Wash skin with plenty of water and soap. If skin irritation continues, consult a doctor.

Symptoms:

Irritation. Repeated exposure may cause skin dryness or cracking.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.

Symptoms:

May cause slight irritation.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting. Call a physician immediately. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs.

Symptoms:

Risk of lung oedema. Ingestion may cause nausea and vomiting. May result in aspiration into the lungs, causing chemical pneumonia.

๐Ÿšจ Immediate Medical Attention Required

IF exposed or concerned: Get medical advice/ attention. Obtain medical attention if breathing difficulty persists. If skin irritation continues, consult a doctor. If eye irritation persists: Get medical advice/attention. Call a physician immediately. Treat symptomatically.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
clear.
๐ŸŽจ Colour
light yellow.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Gasoline-like odour.
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not relevant
๐ŸงŠ Melting Point
Not applicable
Critical Property
๐Ÿ’จ Boiling Point
30 200 C EN ISO 3405
Critical Property
๐Ÿ”ฅ Flash Point
-45 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
- 10
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
55 65 kPa EN 13016-1 (37,8C)
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
690 720 kg/m EN ISO 12185 (15C)
Critical Property
๐Ÿ”ฅ Flammability
Extremely flammable liquid and vapour.
๐Ÿ“Š Upper Explosive Limit
8 vol %
๐Ÿ“Š Lower Explosive Limit
1 vol %
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 300 C
๐Ÿ“Š Decomposition Temperature
Not relevant
๐Ÿ’ง Solubility
Soluble in hydrocarbons.
๐Ÿ“Š Partition Coefficient
4.3 4.8 Calculated value
๐Ÿ“Š Solubility In Water
1 6 mg/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
< 1 mm/s (40C)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure good ventilation of the work station. Use spark-/explosionproof appliances and lighting system. Wear recommended personal protective equipment. Handle in accordance with good industrial hygiene and safety procedures.

๐Ÿงค Hand Protection

Protective gloves. Type: Nitrile rubber (NBR), Viton II. Permeation: 6 (> 480 minutes). Thickness: >0,4 mm. Standard: EN 374-2, EN 374-3.

๐Ÿ‘๏ธ Eye Protection

If there is a risk of liquid being splashed : Wear tight fitting safety glasses or facial screen

๐Ÿ˜ท Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment. Device: Reusable half mask. Filter type: Filter AX (brown). Standard: EN 140.

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing

๐ŸŒ Environmental Exposure Controls

Avoid the spillage or runoff entering drains, sewers or watercourses. Professional and Consumer product use leading to emission of volatiles to air. Volatile compounds subject to air emission controls. See Section 7 for information on safe handling.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 1203

๐Ÿ“ฆ Proper Shipping Name

PETROL

๐Ÿ“‹ Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Aspen 2?

The signal word for this substance is "danger".

What is the physical form of Aspen 2?

Aspen 2 is a liquid appearing as clear. with light yellow. color. It has gasoline-like odour. odor.

What is the solubility of Aspen 2?

Soluble in hydrocarbons.

What is Aspen 2 used for?

Fuel for 2-stroke motors.

What are the hazard statements for Aspen 2?

This substance has 5 hazard statements: H224: Extremely flammable liquid and vapour. H304: May be fatal if swallowed and enters airways. H315: Causes skin irritation. H336: May cause drowsiness or dizziness. H413: May cause long lasting harmful effects to aquatic life.

What is the melting point of Aspen 2?

The melting point is Not applicable and the boiling point is 30 200 C EN ISO 3405.