Al

Alkaline-earth silicate wools (AES wools)

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Alkaline-earth silicate wools (AES wools)

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace, automotive and appliance industries, and as passive fire protection systems and firestops.

Overview

Alkaline-earth silicate wools (AES wools) is a white fibre substance commonly used application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace, automotive and appliance industries, and as passive fire protection systems and firestops..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Skin Irr.
Eye Irrit.

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

THERMAL CERAMICS HSE Department company logo - Safety Data Sheet supplier organization

THERMAL CERAMICS HSE Department

manufacturer

๐Ÿ“

Route de Lauterbourg - BP 90148 67163 WISSEMBOURG Cedex

๐ŸŒ

FR

๐Ÿ“ 

+33 (0)3 88 54 29 20

THERMAL CERAMICS LIMITED company logo - Safety Data Sheet supplier organization

THERMAL CERAMICS LIMITED

manufacturer

๐Ÿ“

Tebay Road, Bromborough Wirral, Merseyside CH62 3PH

๐ŸŒ

GB

๐Ÿ“ž

+44 (0) 151 334 4030

๐Ÿ“ 

+44 (0) 151 334 1684

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

THERMAL CERAMICS HSE Department

๐Ÿ“ž

+33(0) 3 88 54 95 50

๐ŸŒ

FR

๐Ÿ•’

only available during office hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

UVCB

General Composition

These products in the form of bulk, blanket (pre-sized or not), strip, die-cut and modules, bloc, log (encapsulated or not) are made of AES wool.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Alkaline-earth silicate wools 436083-99-7* 100% โœ“ Non-hazardous

Composition Notes

* CAS definition: Alkaline earth silicate (AES) consisting of silica (50-82 wt%), calcia and magnesia (18-43 wt%), alumina, titania and zirconia (less than 6 wt%), and trace oxides.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If these become irritated move to a dust free area, drink water and blow nose.

Symptoms:

irritated

๐Ÿ–๏ธ Skin Contact

In case of skin irritation rinse affected areas with water and wash gently. Do not rub or scratch exposed skin.

Symptoms:

skin irritation

๐Ÿ‘๏ธ Eye Contact

In case of eye contact flush abundantly with water; have eye bath available. Do not rub eyes.

๐Ÿšจ Immediate Medical Attention Required

If symptoms persist, seek medical advice.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
White fibre
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
N.A.
๐ŸงŠ Melting Point
> 1200C
Critical Property
๐Ÿ’จ Boiling Point
N.A.
Critical Property
๐Ÿ”ฅ Flash Point
N.A.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
N.A.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
50-240 kg/m3
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
N.A.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
N.A.
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Slight
๐Ÿ“Š Partition Coefficient
N.A.
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Review your applications in order to identify potential sources of dust exposure. Local exhaust ventilation, which collects dust at source, can be used. For example down draft tables, emission controlling tools and materials handling equipment.

๐Ÿงค Hand Protection

Wear gloves.

๐Ÿ‘๏ธ Eye Protection

As necessary wear goggles or safety glasses with side shields.

๐Ÿ˜ท Respiratory Protection

For dust concentrations below the exposure limit value, RPE is not required but FFP2 respirators may be used on a voluntary basis. For short-term operations where excursions are less than ten times the limit value use FFP2 respirators. In case of higher concentrations or where the concentration is not known, please seek advice from your company and/or local Thermal Ceramics' supplier.

๐Ÿฆบ Skin/Body Protection

Wear gloves and work clothes, which are loose fitting at the neck and wrists. Soiled clothes should be cleaned to remove excess fibres before being taken off (e.g. use vacuum cleaning, not compressed air).

๐ŸŒ Environmental Exposure Controls

Refer to local, national or European applicable environmental permitted standards for air, water and soil. For waste, refer to Section 13.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Alkaline-earth silicate wools (AES wools)?

The signal word for this substance is "no signal word".

What is the solubility of Alkaline-earth silicate wools (AES wools)?

Slight

What is Alkaline-earth silicate wools (AES wools) used for?

Application as thermal insulation, heat shields, heat containment, gaskets and expansion joints in industrial furnaces, ovens, kilns, boilers and other process equipment and in the aerospace, automotive and appliance industries, and as passive fire protection systems and firestops.

What is the melting point of Alkaline-earth silicate wools (AES wools)?

The melting point is > 1200C and the boiling point is N.A..