NextSDS Logo
or

ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur
Product Code
100573

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagent for analysis, Chemical production

Overview

ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur commonly used reagent for analysis, chemical production.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Skin Corr. Category 1B H314
Met. Corr. Category 1 H290

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H314: Causes severe skin burns and eye damage.
  • H290: May be corrosive to metals.

Precautionary Statements

  • P280: Wear protective gloves/ protective clothing/ eye protection/ face protection.
  • IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
  • P309: IF exposed or if you feel unwell:
  • P310: Immediately call a POISON CENTER or doctor/ physician.
  • IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA company logo - Safety Data Sheet supplier organization

Merck KGaA

undefined

๐Ÿ“

64271 Darmstadt * Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 6151 72-0

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

Chemical nature Aqueous solution

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
phosphoric acid 7664-38-2 50-100% โš ๏ธ Hazardous

Additional Information

The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com

Composition Notes

For the full text of the H-Statements mentioned in this Section, see Section 16. For the full text of the R-phrases mentioned in this Section, see Section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

fresh air. Call in physician.

Symptoms:

Cough, Shortness of breath, Pain, Spasm, shock

๐Ÿ–๏ธ Skin Contact

wash off with plenty of water. Remove contaminated clothing. Call a physician immediately.

Symptoms:

Irritation and corrosion, Pain, Spasm, shock

๐Ÿ‘๏ธ Eye Contact

rinse out with plenty of water. Immediately call in ophthalmologist.

Symptoms:

Irritation and corrosion, conjunctivitis Risk of blindness!

๐Ÿฝ๏ธ Ingestion/Swallowing

make victim drink water (two glasses at most), avoid vomiting (risk of perforation). Call a physician immediately. Do not attempt to neutralise.

Symptoms:

Irritation and corrosion, Pain, Spasm, shock

๐Ÿšจ Immediate Medical Attention Required

No information available.

Medical Treatment

No information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
odourless
๐Ÿ“Š Odor Threshold
not applicable
๐Ÿงช Ph
< 0,5 at 100 g/l 20 C
๐ŸงŠ Melting Point
ca. 21 C
Critical Property
๐Ÿ’จ Boiling Point
ca. 158 C at 1.013 hPa
Critical Property
๐Ÿ”ฅ Flash Point
does not flash
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No information available.
๐Ÿ’จ Vapor Pressure
2 hPa at 20 C
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
No information available.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,71 g/cm at 20 C
Critical Property
๐Ÿ”ฅ Flammability
No information available.
๐Ÿ“Š Upper Explosive Limit
not applicable
๐Ÿ“Š Lower Explosive Limit
not applicable
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No information available.
๐Ÿ“Š Decomposition Temperature
No information available.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No information available.
๐Ÿ“Š Solubility In Water
at 20 C soluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
May be corrosive to metals.
๐Ÿ“Š Dynamic Viscosity
No information available.
๐Ÿ“Š Kinematic Viscosity
30,5 mm/s at 20 C
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.

๐Ÿงค Hand Protection

full contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: - 480 min; splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: - 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact).

๐Ÿ‘๏ธ Eye Protection

Tightly fitting safety goggles

๐Ÿ˜ท Respiratory Protection

required when vapours/aerosols are generated. Recommended Filter type: Filter P 2 (acc. to DIN 3181) for solid and liquid particles of harmful substances

๐Ÿฆบ Skin/Body Protection

Acid-resistant protective clothing

๐ŸŒ Environmental Exposure Controls

Do not let product enter drains.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 1805

๐Ÿ“ฆ Proper Shipping Name

PHOSPHORIC ACID, SOLUTION

โš ๏ธ Transport Hazard Class

8

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

yes

๐Ÿšข IMDG Maritime Transport Precautions

yes

โœˆ๏ธ IATA Air Transport Precautions

no

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur?

The signal word for this substance is "danger".

What is the physical form of ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur?

ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur is a liquid with colourless color. It has odourless odor.

What is ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur used for?

Reagent for analysis, Chemical production

What are the hazard statements for ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur?

This substance has 2 hazard statements: H314: Causes severe skin burns and eye damage. H290: May be corrosive to metals.

What is the melting point of ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur?

The melting point is ca. 21 C and the boiling point is ca. 158 C at 1.013 hPa.