NextSDS Logo
DY

DYFONATE

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DYFONATE
Product Code
N11842

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory chemicals, Synthesis of substances

Overview

DYFONATE is a form: liquid colour: yellow substance commonly used laboratory chemicals, synthesis of substances.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 1 H300
Acute Tox. Category 2 H330
Acute Tox. Category 1 H310
Aquatic Acute Category 1 H400
Aquatic Chronic Category 1 H410

GHS Hazard Pictograms & Safety Symbols

GHS06 GHS Hazard Pictogram: Acute toxicity hazard - Poisonous materials that can cause death or serious harm

GHS06

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H300: Fatal if swallowed, in contact with skin or if inhaled
  • H330: Fatal if swallowed, in contact with skin or if inhaled
  • H310: Fatal if swallowed, in contact with skin or if inhaled
  • H410: Very toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P260: Do not breathe dust/ fume/ gas/ mist/ vapours/ spray.
  • P262: Do not get in eyes, on skin, or on clothing.
  • P264: Wash skin thoroughly after handling.
  • P270: Do not eat, drink or smoke when using this product.
  • P271: Use only outdoors or in a well-ventilated area.
  • P273: Avoid release to the environment.
  • P280: Wear protective gloves/ protective clothing.
  • P284: Wear respiratory protection.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor.
  • P302+P350: IF ON SKIN: Gently wash with plenty of soap and water.
  • P304+P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
  • P310: Immediately call a POISON CENTER/doctor.
  • P320: Specific treatment is urgent (see supplemental first aid instructions on this label).
  • P330: Rinse mouth.
  • P361: Remove/Take off immediately all contaminated clothing.
  • P363: Wash contaminated clothing before reuse.
  • P391: Collect spillage.
  • P403+P233: Store in a well-ventilated place. Keep container tightly closed.
  • P405: Store locked up.
  • P501: Dispose of contents/ container to an approved waste disposal plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma-Aldrich

manufacturer

๐Ÿ“

3050 Spruce Street, SAINT LOUIS MO 63103, USA

๐ŸŒ

US

๐Ÿ“ž

+1 800-325-5832

๐Ÿ“ 

+1 800-325-5052

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

+1-703-527-3887

๐ŸŒ

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Fonofos
EC: 213-408-0
944-22-9 100% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

๐Ÿ–๏ธ Skin Contact

Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.

๐Ÿ‘๏ธ Eye Contact

Flush eyes with water as a precaution.

๐Ÿฝ๏ธ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

๐Ÿšจ Immediate Medical Attention Required

No data available

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

๐Ÿ”ฅ Fire Fighting Instructions

Wear self-contained breathing apparatus for firefighting if necessary.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐Ÿšจ Emergency Procedures

Evacuate personnel to safe areas.

๐ŸŒ Environmental Precautions

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

๐Ÿงน Cleanup Methods

Keep in suitable, closed containers for disposal.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Form: liquid Colour: yellow
๐ŸŽจ Colour
yellow
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
No data available
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No data available
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
130 ยฐโ„ƒ (266 ยฐF) at 0.09 hPa (0.07 mmHg)
Critical Property
๐Ÿ”ฅ Flash Point
No data available
Critical Property
๐Ÿ“Š Freezing Point
No data available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
No data available
๐Ÿ“Š Relative Density
No data available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
No data available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
No data available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Avoid contact with skin and eyes.

โ€ข Avoid inhalation of vapour or mist.

๐Ÿช Storage Conditions

โ€ข Keep container tightly closed in a dry and well-ventilated place.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the product.

๐Ÿงค Hand Protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

๐Ÿ‘๏ธ Eye Protection

Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

๐Ÿ˜ท Respiratory Protection

Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

๐Ÿฆบ Skin/Body Protection

Complete suit protecting against chemicals. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

๐ŸŒ Environmental Exposure Controls

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

Stable under recommended storage conditions.

๐Ÿงช Incompatible Materials

Strong oxidizing agents

๐Ÿ’จ Hazardous Decomposition Products

Hazardous decomposition products formed under fire conditions. - Carbon oxides, Sulphur oxides, Oxides of phosphorus. Other decomposition products - No data available.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Toxicity

Toxicity to fish LC50 - Oncorhynchus mykiss (rainbow trout) - 0.02 mg/l - 96.0 h Toxicity to daphnia and other aquatic EC50 - Daphnia magna (Water flea) - 0.002 - 0.020 mg/l - 48 h invertebrates

๐ŸŒฑ Persistence and degradability

No data available

๐ŸŒฑ Bioaccumulative potential

No data available

๐ŸŒฑ Mobility in soil

No data available

๐ŸŒฑ Results of PBT and vPvB assessment

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

๐ŸŒฑ Other adverse effects

An environmental hazard cannot be excluded in the event of unprofessional handling or disposal. Very toxic to aquatic life with long lasting effects.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

โ™ป๏ธ Waste Treatment Methods

Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.

๐Ÿ—‚๏ธ Product Disposal Recommendations

Dispose of as unused product.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

2810

๐Ÿ“ฆ Proper Shipping Name

Toxic, liquids, organic, n.o.s. (Fonofos)

โš ๏ธ Transport Hazard Class

6.1

๐Ÿ“‹ Packing Group

I

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

๐Ÿ“‹ Regulatory Summary

This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.

โŒ Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

โ„น๏ธ Additional Regulatory Information

This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DYFONATE?

The signal word for this substance is "danger".

What is the physical form of DYFONATE?

DYFONATE is a liquid appearing as form: liquid colour: yellow with yellow color. It has no data available odor.

What is the solubility of DYFONATE?

No data available

What is DYFONATE used for?

Laboratory chemicals, Synthesis of substances

What are the hazard statements for DYFONATE?

This substance has 4 hazard statements: H300: Fatal if swallowed, in contact with skin or if inhaled H330: Fatal if swallowed, in contact with skin or if inhaled H310: Fatal if swallowed, in contact with skin or if inhaled H410: Very toxic to aquatic life with long lasting effects.

What is the melting point of DYFONATE?

The melting point is No data available and the boiling point is 130 ยฐโ„ƒ (266 ยฐF) at 0.09 hPa (0.07 mmHg).