NextSDS Logo
Safety Data Sheet EN

Peptid4® S-Control

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Peptid4® S-Control
Chemical Name
Propanediol (and) Tripeptide-85 (and) Water

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites / PC39 - Cosmetics, Personal Care Products.

Manufacturers & Suppliers

C

Chemyunion Ltda

manufacturer

Avenida Independência, 1501, Iporanga. CEP: 18087-101- Sorocaba – São Paulo.

+55 (15) 2102-2000

Emergency Contacts

Emergency Contact

+55 (15) 2102-2002

Emergency Contact

+55 (15) 2102-2086

Suatrans

+55 (11) 3526-3526

Suatrans

0800 707 7022

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Tripeptide consisting of glutamic acid, valine and phenylalanine in 1,3-propanediol.

Chemical Name CAS Number Concentration Hazardous
Propanediol 504-63-2 97.5 - 99% No
Tripeptide-85 31461-61-7 0.5 - 1.5% No
Water (EU: Aqua; JPN: Onsen-Sui) 7732-18-5 0.5 - 1% No

None.

Notes

None.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the victim to fresh air and seek immediate medical attention, if necessary. If not breathing, give artificial respiration or oxygen.

Skin contact

Wash skin with soap and water and remove the contaminated clothes and shoes. If skin irritation persists, seek medical attention.

Eye contact

Flush eyes with plenty of clean water, keeping the eyes opened to assure the product's removal. Seek medical attention immediately, if necessary.

Ingestion

Wash mouth abundantly with water. Do not induce vomit or ingest liquid unless directed to do so by medical personnel. Never give anything by month to an unconscious person. Obtain medical attention.

Immediate Medical Attention

If necessary, look for medical attention immediately taking the label or SDS of the product.

Medical Treatment

Symptomatic treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical, carbon dioxide, foam, and water in fog form.

Unsuitable media

Do not use direct water stream, unless operated by trained person.

Specific hazards

In case of fire, carbon dioxide, carbon monoxide and water in fog form may be released. In certain combustion conditions, traces of other toxic substances may not be excluded.

Firefighter Protection

Full protective clothing including self contained breathing apparatus (SCBA).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use suitable protective equipment (Section 8). Floor may become slippery.

Environmental

Avoid material from entering drains and rivers.

Cleanup methods

Remove the product mechanically with adequate absorbent material, as shovel, broom, etc. Water is indicated to be used freely with any common detergent.

Materials: shovel, broom, absorbent material, water, common detergent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep preemptively away from sources of ignition and heat.

Storage

Store under refrigeration between 2 to 8°C. The product may present precipitate formation, it is recommended to shake before use. Product remains stable until expiry date indicated if stored in its original sealed packaging.

Hygiene

Wash contaminated clothing before reuse. Wash hands before and after handling. Use disposable surgical mask to prevent contamination of the product. Do not eat, drink or smoke when handling the product.

Fire prevention

Not applicable. Product not flammable under usual conditions. Keep preemptively away from sources of ignition and heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use appropriated protection equipment. No engineering control measure is required. However, it is recommended ensure adequate ventilation and keep shower and eyewash near the workplace. No special requirements under normal use conditions.

Hands

Protective gloves.

Eyes

Safety glasses.

Respiratory

Disposable mask.

Skin/Body

Apron and rubber or PVC boots.

Environmental

Avoid material from entering drains and rivers. No special requirements under normal use conditions.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
Not available
Solidification Point
---
Partition Coefficient
Not available
Molecular Weight
---
Density
---
Lower Explosive Limit
Not available
Flash Point
Not available
Melting Point
Not available
Cloud Point
---
Vapor Pressure
Not applicable
Colour
Colorless to light yellow
Voc Content
---
State Under Standard Conditions
---
Form
---
Physical State
Limpid to opalescent liquid
Colour Intensity
---
Crystallisation Point
---
Odor
Characteristic
Evaporation Rate
Not available
Solubility In Fat
Insoluble in oils
Boiling Point
Not available
Freezing Point
Not available
Ph
Not available
Metal Corrosion
---
Explosive Limits
---
Dynamic Viscosity
---
Odor Threshold
Not available
Solubility In Water
Soluble in water
Solubility
Soluble in water, glycols and alcohols. Insoluble in oils.
Softening Point
---
Relative Density
Not available
Properties Status
---
Physical State Data
liquid
Kinematic Viscosity
---
Decomposition Temperature
Not available
Auto Ignition Temperature
Not available
Appearance
Limpid to opalescent liquid. Colorless to light yellow. The product may present precipitate formation.
Bulk Density
---
Vapor Density
Not applicable
Relative Evaporation Rate
---
Flammability
Not available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Product is stable under regular conditions.

Reactivity

Not available.

Hazardous reactions

None known.

Avoid

Dust, humidity, open packaging, inappropriate handling and elevated temperatures.

Incompatible

Strong oxidizing agents. Sulfuric acid. Phosphoric acid. Acetic anhydride.

Decomposition

In case of fire, carbon dioxide, carbon monoxide and water in fog form may be released. In certain combustion conditions, traces of other toxic substances may not be excluded.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose in compliance with local laws and regulation.

Disposal

Do not reuse the package. Dispose in compliance with local laws and regulation.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

In compliance with Occupational Safety and Health regulations.

Chemical Safety Assessment Not performed

None.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Peptid4® S-Control?

The signal word is no signal word.

What is the physical form of Peptid4® S-Control?

Peptid4® S-Control is a limpid to opalescent liquid appearing as limpid to opalescent liquid. colorless to light yellow. the product may present precipitate formation. with colorless to light yellow color. It has characteristic odor.

What is the solubility of Peptid4® S-Control?

Soluble in water, glycols and alcohols. Insoluble in oils.

What is Peptid4® S-Control used for?

SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites / PC39 - Cosmetics, Personal Care Products.

What is the melting point of Peptid4® S-Control?

The melting point is Not available and the boiling point is Not available.