NextSDS Logo
Li

Lithium-I on Rechargeable Battery Pack BL1041B

Solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Lithium-I on Rechargeable Battery Pack BL1041B
Product Code
BL1041B

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

Lithium-I on Rechargeable Battery Pack BL1041B .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

N/A

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Makita U.S.A., Inc.

manufacturer

๐Ÿ“

14930-C Northam Street, La Mirada, CA 90638

๐ŸŒ

US

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

1-800-424-9300

๐ŸŒ

US

๐Ÿ’ก

For Chemical Emergency Spills, Leak, Fire, Exposure, or Accident

MAKITA

๐Ÿ“ž

1-510-657-9881

๐ŸŒ

US

๐Ÿ’ก

Telephone Number for Information

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Aluminum Foil 7429-90-5 2-10% โš ๏ธ Hazardous
Metal Oxide N/A 20-50% โš ๏ธ Hazardous
Polyvinylidene Fluoride 24937-79-9 5% โš ๏ธ Hazardous
Copper Foil 7440-50-8 2-10% โš ๏ธ Hazardous
Carbon 7440-44-0 10-30% โš ๏ธ Hazardous
Electrolyte N/A 10-20% โš ๏ธ Hazardous
Stainless steel, Nickel and inert materials N/A Not specified โœ“ Non-hazardous
Lead 7439-92-1 0.001% โš ๏ธ Hazardous
Mercury 7439-97-6 Not specified โš ๏ธ Hazardous
Chromium 7440-47-3 Not specified โš ๏ธ Hazardous
Cadmium 7440-43-9 Not specified โš ๏ธ Hazardous
Plastic case and Si2O N/A Not specified โœ“ Non-hazardous
Lead 7439-92-1 0.1% โš ๏ธ Hazardous
Nickle 7440-02-0 0.01% โš ๏ธ Hazardous
CFCs 75-69-4 Not specified โš ๏ธ Hazardous
Polyclorinated Biphenyls 1336-36-3 Not specified โš ๏ธ Hazardous

Additional Information

Watt-hour rating: Under 100 WH

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Leave area immediately and seek medical attention.

๐Ÿ–๏ธ Skin Contact

Wash area thoroughly with soap and water and seek medical attention.

๐Ÿ‘๏ธ Eye Contact

Rinse eyes with water for 15 minutes and seek medical attention.

๐Ÿฝ๏ธ Ingestion/Swallowing

Drink milk/water and induce vomiting; seek medical attention.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Use extinguishing media suitable for the materials that are burning.

โš ๏ธ Specific Fire Hazards

Cell is not flammable but internal organic material will burn if the cell is incinerated. Combustion products include, but are not limited to hydrogen fluoride, carbon monoxide and carbon dioxide.

๐Ÿ”ฅ Fire Fighting Instructions

If possible, remove cell(s) from firefighting area. If heated above 125โ„ƒ, cell(s) can explode/vent.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Use NIOSH/MSHA approved full-face self-contained breathing apparatus (SCBA) with full protective gear.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Insoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข No special protective clothing required for handling individual cells.

๐Ÿช Storage Conditions

โ€ข Store in a cool, dry place.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Keep away from heat and open fame. Store in a cool dry place.

๐Ÿงค Hand Protection

Not required for handling of cells.

๐Ÿ‘๏ธ Eye Protection

Not required beyond safety practices of employer.

๐Ÿ˜ท Respiratory Protection

Not required during normal operations. SCBA required in the event of a fire.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

๐Ÿšซ Conditions to Avoid

Avoid exposure to heat and open flame. Do not puncture, crush or incinerate.

๐Ÿงช Incompatible Materials

None during normal operation. Avoid exposure to heat, open flame, and corrosives.

๐Ÿ’จ Hazardous Decomposition Products

None during normal operating conditions. If cells are opened, hydrogen fluoride and carbon monoxide may be released.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Toxicity

Some materials within the cell are bio-accumulative. Under normal conditions, these materials are contained and pose no risk to persons or the surrounding environment.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

๐Ÿ—‚๏ธ Product Disposal Recommendations

Dispose of according to all federal, state, and local regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3480

๐Ÿ“ฆ Proper Shipping Name

Lithium-ion batteries

โš ๏ธ Transport Hazard Class

9

๐Ÿ“‹ Packing Group

II

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

๐Ÿ“‹ Regulatory Summary

OSHA hazard communication standard (29 CFR 1910.1200)

โŒ Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the physical form of Lithium-I on Rechargeable Battery Pack BL1041B?

Lithium-I on Rechargeable Battery Pack BL1041B is a solid .