NextSDS Logo
Safety Data Sheet EN

Clinal B+

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Clinal B+
Product Form
Liquid

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial

Manufacturers & Suppliers

M

Mr. Gewillig

distributor

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Skin Corr.

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This product is considered to be hazardous and contains hazardous components.

Chemical Name CAS Number Concentration Hazardous
Potassium hydroxide EC: 215-181-3 1310-58-3 5 - 10% Yes
Capryleth-9 carboxylic acid 107600-33-9 5% Yes
Hexeth-4 carboxylic acid 105391-15-9 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air. Allow the victim to rest. Take to hospital.

Symptoms: Risk of lungs oedema.

Skin contact

Remove contaminated clothing and shoes. Flush with plenty of water. Obtain medical attention.

Eye contact

Rinse immediately with plenty of water. Seek medical attention immediately.

Ingestion

Rinse mouth. DO NOT INDUCE VOMITING. Take to hospital.

Immediate Medical Attention

Take to hospital.

Medical Treatment

Rest and hospitalization essential.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

All extinguishing media can be used.

Specific hazards

May release heat and harmful fumes.

Instructions

Exercise caution when fighting any chemical fire.

Firefighter Protection

Wear proper protective equipment. Use self-contained breathing apparatus when in close proximity to fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Spill should be handled by trained cleaning personnel properly equipped with respiratory and eye protection. Evacuate and limit access.

Environmental

Prevent entry to sewers and public waters.

Cleanup methods

Clean up any spills as soon as possible using absorbing material to collect Dilute residues and flush.

Materials: absorbing material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle in accordance with good industrial hygiene and safety procedures. Ensure prompt removal from eyes, skin and clothing. Wash hands and other exposed areas with mild soap and water before eat, drink or smoke and when leaving work.

Storage

Keep container closed when not in use. Do not store in corrodable metal.

Hygiene

Wash hands and other exposed areas with mild soap and water before eat, drink or smoke and when leaving work.

Fire prevention

Use only non-sparking tools.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Local exhaust and general ventilation must be adequate to meet exposure standards.

Hands

protective gloves

Eyes

Chemical goggles or face shield with safety glasses.

Respiratory

Approved dust or mist respirator should be used if airborne particles are generated when handling this material.

Skin/Body

apron, boots, head and face protection must be worn.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless.
Colour Intensity
---
Form
---
Odor
Light.
Odor Threshold
---
Ph
13.90
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1.16 kg/l
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
100 %
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Hazardous reactions

Reacts violently with : Acids.

Incompatible

Metals

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose of this material and its container at hazardous or special waste collection point. Dispose in a safe manner in accordance with local/national regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3266
Shipping Name
BIJTENDE BASISCHE ANORGANISCHE VLOEISTOF, N.E.G.
Transport Class
8
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Symbol(s) : Corrosive. R Phrase(s) : R35 : Causes severe burns. S Phrase(s) : S26 : In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. S36/37/39 : Wear suitable protective clothing, gloves and eye/face protection. S45 : In case of accident or if you feel unwell, seek medical advice immediately (show the label when possible).

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Clinal B+?

The signal word is na: r-phrases.

What is the physical form of Clinal B+?

Clinal B+ is a liquid. with colourless. color. It has light. odor.

What is Clinal B+ used for?

Industrial