NextSDS Logo
CL

CLEANING LIQUID, (ESL5) 100ML, CLEANING LIQUID, (ESL5) 500ML, ECO-UV, ESL5P-CL

WARNING SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
CLEANING LIQUID, (ESL5) 100ML, CLEANING LIQUID, (ESL5) 500ML, ECO-UV, ESL5P-CL

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Cleaning liquid

Overview

CLEANING LIQUID, (ESL5) 100ML, CLEANING LIQUID, (ESL5) 500ML, ECO-UV, ESL5P-CL is a clear liquid substance commonly used cleaning liquid.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Flam. Liq. Category 4

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H227: Combustible liquid.

Precautionary Statements

  • Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • Wear protective gloves/protective clothing/eye protection/face protection.
  • Store in a well-ventilated place. Keep cool.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Roland DG Corporation

manufacturer

๐Ÿ“

1-6-4 Shinmiyakoda, Kita-ku, Hamamatsu-shi, Shizuoka-ken, 431-2103

๐ŸŒ

JP

๐Ÿ“ž

+ 81-53-484-1224

๐Ÿ“ 

+ 81-53-484-1226

Roland DGA Corporation

importer

๐Ÿ“

15363 Barranca Parkway Irvine, CA 92618 U.S.A.

๐ŸŒ

US

๐Ÿ“ 

+1-949-727-2112

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Roland DGA Corporation

๐Ÿ“ž

+1-949-727-2100

๐ŸŒ

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Dialkylene glycol dialkyl ether CBI 50-60% โœ“ Non-hazardous
Polyalkylene glycol monoalkyl ether CBI 50-60% โœ“ Non-hazardous

Additional Information

Chemical name and exact concentrations are being withheld as trade secrets.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.

Symptoms:

respiratory irritation

๐Ÿ–๏ธ Skin Contact

In case of contact, immediately flush with plenty of water while removing contaminated clothing and shoes. Wash contaminated clothing before reuse.

Symptoms:

swelling, redness, irritation

๐Ÿ‘๏ธ Eye Contact

In case of contact, immediately flush eyes with plenty of water for several minutes. Hold eyelids open during flushing.

Symptoms:

irritation

๐Ÿฝ๏ธ Ingestion/Swallowing

DO NOT induce vomiting.

๐Ÿšจ Immediate Medical Attention Required

Call a physician. Seek immediate medical advice.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Clear Liquid
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Slightly odour
๐Ÿ“Š Odor Threshold
Not defined
๐Ÿงช Ph
Not applicable
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
159.8deg.F
Critical Property
๐Ÿ“Š Freezing Point
No data available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
>1
๐Ÿ“Š Relative Density
0.9-1.1
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not applicable
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
soluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
980 g / L
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide general and/or local exhaust ventilation.

๐Ÿงค Hand Protection

Not required under suitable use as setting the cleaning liquid on the printer. However, in case of direct contact to the cleaning liquid, use protective gloves. Recommended impervious gloves is butyl rubber glove.

๐Ÿ‘๏ธ Eye Protection

Not required under suitable use as setting the cleaning liquid on the printer. However, in case of direct contact to the cleaning liquid, wear safety glasses or chemical splash goggles.

๐Ÿ˜ท Respiratory Protection

In case ventilation is insufficient, employee must use NIOSH approved air purifying respiratory equipment. Use a half facepiece respirator (with goggles) or full face-piece respirator (without goggles) filtered with organic vapor cartridge.For emergency and other conditions where the exposure guideline may be exceeded, use an approved positive-pressure self-contained breathing apparatus or positive-pressure airline with auxiliary self contained air supply. WARNING: Air-purifying respirators do not protect workers in oxygen-deficient atmospheres.

๐Ÿฆบ Skin/Body Protection

Not required under suitable use as setting the cleaning liquid on the printer. However, in case of direct contact to the cleaning liquid, wear protective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

Not regulated

๐Ÿ“ฆ Proper Shipping Name

Not regulated

โš ๏ธ Transport Hazard Class

Not regulated

๐Ÿ“‹ Packing Group

Not regulated

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for CLEANING LIQUID, (ESL5) 100ML, CLEANING LIQUID, (ESL5) 500ML, ECO-UV, ESL5P-CL?

The signal word for this substance is "warning".

What is CLEANING LIQUID, (ESL5) 100ML, CLEANING LIQUID, (ESL5) 500ML, ECO-UV, ESL5P-CL used for?

Cleaning liquid

What are the hazard statements for CLEANING LIQUID, (ESL5) 100ML, CLEANING LIQUID, (ESL5) 500ML, ECO-UV, ESL5P-CL?

This substance has 1 hazard statements: H227: Combustible liquid.

What is the melting point of CLEANING LIQUID, (ESL5) 100ML, CLEANING LIQUID, (ESL5) 500ML, ECO-UV, ESL5P-CL?

The melting point is No data available and the boiling point is No data available.