NextSDS Logo
Hy

HyPrene Olympus L500

NO SIGNAL WORD Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
HyPrene Olympus L500
Product Code
649-465-00-7 (Index number)

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Tire Oils, Rubber Compounding, Automotive & Industrial Hoses, Dedusting, Plasticizer, Titanium Dioxide Wash, Compressor Wash Oils, Hydraulic Fracturing Oil, Adhesives, Carpet Backing, Feed Stock for White Oil, Refrigeration Oil, Diluents and Carriers, Carbon Black, Banbury Dust Stop, Defoamers, Sealants, Belts & Hoses, Coatings, Leather Tanning, Agriculture Oils.
Uses Advised Against
None known.

Overview

HyPrene Olympus L500 is a clear & bright substance commonly used tire oils, rubber compounding, automotive & industrial hoses, dedusting, plasticizer, titanium dioxide wash, compressor wash oils, hydraulic fracturing oil, adhesives, carpet backing, feed stock for white oil, refrigeration oil, diluents and carriers, carbon black, banbury dust stop, defoamers, sealants, belts & hoses, coatings, leather tanning, agriculture oils..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Not applicable.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Ergon, Inc.

manufacturer

๐Ÿ“

P.O. Box 1639 Jackson, MS 39181 USA

๐ŸŒ

US

Ergon International, Inc.

importer

๐Ÿ“

Drve Richelle 161 Building C B-1410 Waterloo, Belgium

๐ŸŒ

BE

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

US Customer Service

๐Ÿ“ž

+ 1-800-222-7122

๐ŸŒ

US

Chemtrec

๐Ÿ“ž

+ 1-800-424-9300

๐ŸŒ

US

๐Ÿ•’

After Business Hours

๐Ÿ’ก

North America. See Section 15 for additional CHEMTREC Hotline Numbers

Chemtrec

๐Ÿ“ž

+ 1-703-527.-3887

๐Ÿ’ก

International. See Section 15 for additional CHEMTREC Hotline Numbers

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy naphthenic
EC: 265-155-0
64742-52-5 100% โœ“ Non-hazardous

Composition Notes

Note L - Not classified as a carcinogen. Meets EU requirement of less than 3% (w/w) DMSO extract for total polycyclic aromatic compound (PAC) using IP 346.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air. Oxygen or artificial respiration if needed. IF exposed or concerned: Get medical advice/attention.

๐Ÿ–๏ธ Skin Contact

Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If skin irritation or an allergic skin reaction develops, get medical attention.

Symptoms:

Skin irritation, allergic skin reaction, defatting of the skin.

๐Ÿ‘๏ธ Eye Contact

Flush thoroughly with water. If irritation occurs, get medical assistance.

Symptoms:

Irritation.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Call a poison control centre immediately.

Symptoms:

Vomiting, risk of aspiration.

๐Ÿšจ Immediate Medical Attention Required

Treat symptomatically.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Clear & bright
๐ŸŽจ Colour
Light Amber
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid.
๐Ÿ‘ƒ Odor
Mild Petroleum Odor
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not applicable
๐ŸงŠ Melting Point
-35 C (-31 F) ASTM D5949
Critical Property
๐Ÿ’จ Boiling Point
306,11 C (583 F) ASTM D2887/ ISO 3294
Critical Property
๐Ÿ”ฅ Flash Point
212,0 C (413,6 F) Pensky-Martens Closed Cup ASTM D93 224,0 C (435,2 F) Cleveland open cup ASTM D92/ ISO 2592
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
Not available.
๐Ÿ“Š Vapor Density
- 5
๐Ÿ“Š Relative Density
0,91 (15,56 C (60 F) ASTM D4052/ ISO 12185)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available.
๐Ÿ“Š Upper Explosive Limit
Not available.
๐Ÿ“Š Lower Explosive Limit
Not available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 315,56 C (> 600 F) ASTM E659
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not established.
๐Ÿ“Š Solubility In Water
Insoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
95,4 cSt (40 C (104 F) ASTM D445/ ISO 3104)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.

๐Ÿงค Hand Protection

Chemical resistant gloves are recommended. If contact with forearms is likely wear gauntlet style gloves. When prolonged or frequent repeated contact occurs, Nitrile gloves may be suitable. (Breakthrough time of > 240 minutes.) For incidental contact/splash protection Neoprene, PVC gloves may be suitable.

๐Ÿ‘๏ธ Eye Protection

Goggles/face shield are recommended.

๐Ÿ˜ท Respiratory Protection

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [boiling point >65 C (149 F)] meeting EN14387. When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Under normal conditions, respirator is not normally required.

๐Ÿฆบ Skin/Body Protection

Chemical/oil resistant clothing is recommended. Launder contaminated clothing before reuse.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for HyPrene Olympus L500?

The signal word for this substance is "no signal word".

What is the physical form of HyPrene Olympus L500?

HyPrene Olympus L500 is a liquid. appearing as clear & bright with light amber color. It has mild petroleum odor odor.

What is HyPrene Olympus L500 used for?

Tire Oils, Rubber Compounding, Automotive & Industrial Hoses, Dedusting, Plasticizer, Titanium Dioxide Wash, Compressor Wash Oils, Hydraulic Fracturing Oil, Adhesives, Carpet Backing, Feed Stock for White Oil, Refrigeration Oil, Diluents and Carriers, Carbon Black, Banbury Dust Stop, Defoamers, Sealants, Belts & Hoses, Coatings, Leather Tanning, Agriculture Oils.

What is the melting point of HyPrene Olympus L500?

The melting point is -35 C (-31 F) ASTM D5949 and the boiling point is 306,11 C (583 F) ASTM D2887/ ISO 3294.