Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Trionic D Spray
- Product Form
- aqueous solution in a trigger spray format
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
An aqueous solution in a trigger spray format for cleaning/disinfecting medical devices and equipment.
Manufacturers & Suppliers
Ebiox Ltd
distributor
822 Fountain Court, Birchwood Boulevard, Birchwood, Warrington, WA3 7QZ, UK
+44 (0) 1925 202205
Ebiox Ltd
manufacturer
822 Fountain Court, Birchwood Boulevard, Birchwood, Warrington WA3 7QZ
Emergency Contacts
UK National Poisons Information Service
0870 600 6266
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
An aqueous solution of a proprietary blend of non-ionic and amphoteric Surfactants plus three cationic biocides
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| C12/16 ALKYL DIMETHYLBENZYL AMMONIUM CHLORIDE EC: 270-325-2 | 68424-85-1 | 0.2 - 0.3% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air. If necessary, seek medical advice.
Clean areas of skin affected with soap water. If necessary, seek medical advice.
Wash out eye thoroughly with plenty of water until irritation subsides; if necessary, consult an eye specialist/ophthalmologist.
If product is swallowed, do NOT induce vomiting. Drink plenty of water; if necessary, seek medical advice.
Immediate Medical Attention
If necessary, seek medical advice.
Medical Treatment
Treatment as described above. Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water spray, carbon dioxide, foam or chemical powder
water jet
Decomposition products released in a fire (e.g. oxides of carbon) should be considered as probably harmful if inhaled.
Avoid run-off water entering the drains (e.g. use barriers)
Firefighter Protection
Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to get into waste water or waterways; if this occurs, inform the relevant water authority at once.
Take up excess liquid with absorbent material, e.g. sand, sawdust into tightly closable containers.
Materials: absorbent material, e.g. sand, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle in accordance with good hygiene and safety practice.
Ensure adequate ventilation of the storage area. Keep containers cool and dry.
Handle in accordance with good hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation (e.g. local exhaust ventilation).
Suitable gloves (also consider your own risk assessment; e.g. breakthrough times, rates of diffusion and degradation, tasks undertaken)
Safety goggles if eye contamination is likely
Approved respirator (e.g. EN 149:2001 FFP3) only if ventilation is insufficient.
Protective overall
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable
Stable under normal conditions of handling
None known
None known
None known
None known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
In accordance with national and local authority regulations, e.g. The Hazardous Waste (England & Wales) Regulations 2005.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product is classified in according with Regulation (EC) No 1272/2008 and Regulation (EC) No 1907/2006, on the basis of available information for the ingredients from supplier safety data sheets
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Trionic D Spray?
The signal word is no signal word.
What is the physical form of Trionic D Spray?
Trionic D Spray is a clear liquid appearing as clear with colourless color. It has fragranced odor.
What is Trionic D Spray used for?
An aqueous solution in a trigger spray format for cleaning/disinfecting medical devices and equipment.
What is the melting point of Trionic D Spray?