NextSDS Logo
WD

WD-40® MULTI-USE PRODUCT - [Aerosol]

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
WD-40® MULTI-USE PRODUCT - [Aerosol]
Product Form
Aerosol
Synonyms
WD-40® MULTIFUNCTIONEEL PRODUCT - PRODUIT MULTIFONCTION

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Corrosiebescherming, Smeermiddel
Uses Advised Against
Er is momenteel geen informatie hierover.

Overview

WD-40® MULTI-USE PRODUCT - [Aerosol] is a lichtbruin substance commonly used corrosiebescherming, smeermiddel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

STOT SE Category 3 H336
Aerosol Category 1 H222
Asp. Tox. Category 1 H304
Aerosol Category 1 H229

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H222: Zeer licht ontvlambare aerosol.
  • H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt.
  • H229: Houder onder druk: kan openbarsten bij verhitting.

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P261: Inademing van gas of spuitnevel vermijden.
  • P271: Alleen buiten of in een goed geventileerde ruimte gebruiken.
  • NA INSLIKKEN: onmiddellijk een ANTIGIFCENTRUM / arts raadplegen. GEEN braken opwekken.
  • P312: Bij onwel voelen een ANTIGIFCENTRUM / arts raadplegen.
  • P405: Achter slot bewaren.
  • P410+P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 ℃.
  • P501: Inhoud / verpakking op een veilige manier afvoeren ter verwijdering.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

WD-40 Company Limited company logo - Safety Data Sheet supplier organization

WD-40 Company Limited

manufacturer

📍

PO Box 440, Kiln Farm, Milton Keynes, MK11 3LF, Het Verenigd Koninkrijk

🌍

GB

📞

+44 (0) 1908 555400

📠

+44 (0) 1908 266900

WD-40 Company Limited

manufacturer

📍

Noorderpoort 97, 5916PJ Venlo, Nederland

🌍

NL

📞

+31 85 487 46 91

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

NVIC Nationaal Vergiftigingen Informatie Centrum - RIVM Rijksinstituut voor Volksgezondheid en Milieu

📞

030-2748888

🌍

NL

🕒

24 h

💡

Uitsluitend bestemd om professionele hulpverleners te informeren bij acute vergiftigingen.

Antigifcentrum/Centre Antipoisons (België)

📞

+32 70 245245

🌍

BE

🕒

24 uur

💡

Een arts beantwoordt uw oproep, elke dag, 24 op 24 uur.

WDC

📞

+49 (0) 700 / 24 112 112

💡

Telefoonnummer van het bedrijf voor noodgevallen.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Aërosol

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Koolwaterstoffen, C9-C11, n-alkanen, isoalkanen, cycloalkanen, <2% aromaten
EC: 919-857-5 (REACH-IT List-No.)
N/A 60-80% ⚠️ Hazardous
Kooldioxide
EC: 204-696-9
124-38-9 1-5% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🖐️ Skin Contact

Verontreinigde, doordrenkte kledingstukken meteen verwijderen, met veel water en zeep grondig wassen, bij huidirritatie (rood worden etc.), een arts raadplegen.

👁️ Eye Contact

Kontaktlenzen uitnemen. Enkele min. met overvloedig water spoelen (oogdouche), indien nodig arts raadplegen.

Symptoms:

Irritatie van de ogen.

🍽️ Ingestion/Swallowing

Mond goed spoelen met water. Meteen arts raadplegen, veiligheidsinformatieblad meenemen. Geen braken opwekken.

Symptoms:

Misselijkheid, Braken, Diarree, Aspiratiegevaar.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Schuim, CO2, Bluspoeder, Waterstraal

Unsuitable Extinguishing Media

Harde waterstraal

⚠️ Specific Fire Hazards

Bij brand kunnen onstaan: Kooloxides, Barstgevaar bij het verhitten, Explosiegevaar bij langdurige verhitting. Ontplofbare damp/luchtmengsels

🔥 Fire Fighting Instructions

Al naargelang de grootte van de brand, Apparaat voor ademhalingsbescherming onafhankelijk van de omgevingslucht. Bedreigde vaten met water koelen.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🚨 Emergency Procedures

Contact met de ogen, met de huid en inademing vermijden.

🌍 Environmental Precautions

Indringen in oppervlakte- en grondwater en in de grond vermijden.

🧹 Cleanup Methods

Volgens rubriek 13 als afval verwijderen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
liquid
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Lichtbruin
🎨 Colour
Lichtbruin
📊 Colour Intensity
Karakteristiek
📊 Form
Aerosol
👃 Odor
Not available
📊 Odor Threshold
Niet bepaald
🧪 Ph
Not available
🧊 Melting Point
<- 66 ℃ (ASTM D 97, Vloeibaar concentraat )
Critical Property
💨 Boiling Point
176 °℃ (Vloeibaar concentraat )
Critical Property
🔥 Flash Point
47 ℃ (Vloeibaar concentraat )
Critical Property
📊 Freezing Point
Not available
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Niet bepaald
💨 Vapor Pressure
7,2 bar (20℃), 9,4 bar (50℃)
📊 Vapor Density
Niet bepaald
📊 Relative Density
Not available
📊 Bulk Density
n.br.
⚖️ Density
0,817 g/ml (Vloeibaar concentraat )
Critical Property
🔥 Flammability
Ja
📊 Upper Explosive Limit
8,0 Vol-% ((Opgave belangrijkste bestanddeel) )
📊 Lower Explosive Limit
0,6 Vol-% ((Opgave belangrijkste bestanddeel) )
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
Niet bepaald
📊 Decomposition Temperature
Niet bepaald
💧 Solubility
Niet bepaald
📊 Partition Coefficient
Niet bepaald
📊 Solubility In Water
Onoplosbaar
📊 Solubility In Fat
Niet bepaald
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Not available
📊 Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

• Voor voldoende ventilatie zorgen.

• Uit de buurt houden van ontstekingsbronnen - Niet roken.

• Niet gebruiken op hete oppervlakken.

• Instructies op het etiket en gebruiksaanwijzing in acht nemen.

• Werkproces conform gebruiksaanwijzing toepassen.

• Evt.

• maatregelen tegen elektrostatische oplading treffen.

🏪 Storage Conditions

• Ontoegankelijk voor onbevoegden bewaren.

• Product niet opslaan in doorgangen en trappenhuizen.

• Speciale voorschriften voor aerosolen in acht nemen! Bijzondere opslagvoorwaarden naleven.

• Beschermen tegen direct zonlicht en temperaturen boven 50℃.

• Droog bewaren.

• Koel opslaan.

• Op een goed geventileerde plaats opslaan.

🧼 General Hygiene Measures

De algemene hygiënemaatregelen in de omgang met chemicalien moeten worden toegepast. Voor de pauzes en aan het eind van het werk de handen wassen. Verwijderd houden van eet- en drinkwaren en van diervoeder. Voor gebieden te betreden waar wordt gegeten, verontreinigde kleding en beschermingsmiddelen uitdoen.

🔥 Fire Prevention Measures

Uit de buurt houden van ontstekingsbronnen - Niet roken.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Voor goede ventilatie zorgen. Dit kan door lokale afzuiging of algemene afzuiging gerealiseerd worden.

🧤 Hand Protection

Veiligheidshandschoenen van nitril (EN 374) Minimale dikte in mm: >= 0,4 Permeatie (doorbraaktijd) in minuten: >= 480. De vastgestelde doorbraaktijden conform EN 374, deel 3 werden niet verkregen onder praktijkvoorwaarden. Er wordt een maximale draagtijd aanbevolen die overeenkomt met 50% van de doorbraaktijd. Beschermende handcrème aan te bevelen.

👁️ Eye Protection

Volledig aansluitende veiligheidsbril met zijkleppen (EN 166).

😷 Respiratory Protection

Onder normale omstandigheden niet vereist. Bij overschrijding van de grenswaarde (WNG of DE-AGW of BE-GW). Filter A P3 (EN 14387), kleurcode bruin, wit. Draagtijdbeperkingen voor adembeschermingsapparaten in acht nemen.

🦺 Skin/Body Protection

Beschermende werkkleding (bv. veiligheidsschoenen EN ISO 20345, veiligheidskleding met lange mouwen).

🌍 Environmental Exposure Controls

Er is momenteel geen informatie hierover.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stabiel bij juiste opslag en hantering.

⚠️ Hazardous Reactions

Geen gevaarlijke reacties bekend.

🚫 Conditions to Avoid

Verhitting, open vlammen, ontstekingsbronnen. Drukverhoging leidt tot barstgevaar. Houder onder druk. Beschermen tegen de zon en niet blootstellen aan een hogere temperatuur dan 50℃. Ook na gebruik niet doorboren of verbranden.

🧪 Incompatible Materials

Contact met sterke oxidatiemiddelen vermijden.

💨 Hazardous Decomposition Products

Geen ontleding bij conform gebruik.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

🌱 Toxiciteit voor vis

LC50, 96h, >1000, mg/l, Oncorhynchus mykiss, OECD 203 (Fish, Acute Toxicity Test)

🌱 Toxiciteit voor Daphnia

EC50, 48h, >1000, mg/l, Daphnia magna, OECD 202 (Daphnia sp. Acute Immobilisation Test)

🌱 Toxiciteit voor algen

NOELR, 72h, 100, mg/l, Pseudokirchnerie lla subcapitata, OECD 201 (Alga, Growth Inhibition Test)

🌱 Persistentie en afbreekbaarheid

28d, >20- <60, %, OECD 310 (Ready Biodegradability - CO2 in sealed vessels (Headspace Test)), Niet gemakkelijk maar inherent afbreekbaar.

🌱 Resultaten van PBT- en zPzB- beoordeling

Geen PBT-stof, Geen vPvB-stof

🌱 Andere schadelijke effecten

Broeikaseffect

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

Aanbeveling: Ontmoedig de lozing van afvalwater in het milieu. Voorschriften van de plaatselijke instanties opvolgen. Bijvoorbeeld geschikte verbrandingsinstallatie.

🗂️ Product Disposal Recommendations

Voorschriften van de plaatselijke instanties opvolgen.

🏷️ Waste Classification Codes

16 05 04 gassen in drukhouders (inclusief halonen) die gevaarlijke stoffen bevatten EWC
15 01 04 metalen verpakking EWC
15 01 01 papieren en kartonnen verpakking EWC

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

1950

📦 Proper Shipping Name

UN 1950 AEROSOLS

⚠️ Transport Hazard Class

2.1

🚛 ADR Transport Precautions

Persons responsible for the transport of dangerous goods must be trained. Security provisions are binding for all persons involved in the transport. Precautions must be taken to prevent damage.

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

📋 Regulatory Summary

Neem de voorschriften voor veiligheid en gezondheid op de werkplek in acht.

Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

ℹ️ Additional Regulatory Information

Richtlijn 2010/75/EU (VOS): ~ 65,5 % Wet op de kinderarbeid in acht nemen (Duits voorschrift).

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What other names is WD-40® MULTI-USE PRODUCT - [Aerosol] known by?

WD-40® MULTI-USE PRODUCT - [Aerosol] is also known as: WD-40® MULTIFUNCTIONEEL PRODUCT - PRODUIT MULTIFONCTION

What is the hazard signal word for WD-40® MULTI-USE PRODUCT - [Aerosol]?

The signal word for this substance is "danger".

What is the physical form of WD-40® MULTI-USE PRODUCT - [Aerosol]?

WD-40® MULTI-USE PRODUCT - [Aerosol] is a liquid appearing as lichtbruin with lichtbruin color.

What is the solubility of WD-40® MULTI-USE PRODUCT - [Aerosol]?

Niet bepaald

What is WD-40® MULTI-USE PRODUCT - [Aerosol] used for?

Corrosiebescherming, Smeermiddel

What are the hazard statements for WD-40® MULTI-USE PRODUCT - [Aerosol]?

This substance has 4 hazard statements: H336: Kan slaperigheid of duizeligheid veroorzaken. H222: Zeer licht ontvlambare aerosol. H304: Kan dodelijk zijn als de stof bij inslikken in de luchtwegen terechtkomt. H229: Houder onder druk: kan openbarsten bij verhitting.

What is the melting point of WD-40® MULTI-USE PRODUCT - [Aerosol]?

The melting point is <- 66 ℃ (ASTM D 97, Vloeibaar concentraat ) and the boiling point is 176 °℃ (Vloeibaar concentraat ).