NextSDS Logo
Li

Lijmspray

DANGER Aerosol SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Lijmspray

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Kleefstof
Uses Advised Against
Geen verdere relevante informatie verkrijgbaar.

Overview

Lijmspray commonly used kleefstof.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Aerosol Category 1 H222
Aquatic Chronic Category 2 H411
Skin Irr. Category 2 H315
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
  • H315: Veroorzaakt huidirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.
  • H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P211: Niet in een open vuur of op andere ontstekingsbronnen spuiten.
  • P251: Ook na gebruik niet doorboren of verbranden.
  • P261: Inademing van spuitnevel vermijden.
  • P273: Voorkom lozing in het milieu.
  • P410+P412: Tegen zonlicht beschermen. Niet blootstellen aan temperaturen boven 50 ℃/122 ΒΊF.
  • P501: De inhoud/verpakking afvoeren overeenkomstig de nationale voorschriften.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

πŸ“

Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes

🌍

NL

πŸ“ž

+31 88 3235700

πŸ“ 

+31 88 3235800

Bison International

manufacturer

πŸ“

Excelsiorlaan 27, B 3, B-1930 Zaventem

🌍

BE

πŸ“ž

+32 3 710 92 92

πŸ“ 

+32 3 710 92 90

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum

πŸ“ž

070 245245

🌍

BE

Groothertogdom Luxemburg

πŸ“ž

8002 - 5500

🌍

LU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Kleefstof

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
dimethylether
EC: 204-065-8
115-10-6 25-50% ⚠️ Hazardous
nafta (aardolie), met waterstof ontzwavelde lichte, gedearomatiseerd
EC: 931-254-9
64742-49-0 25-50% ⚠️ Hazardous
Koolwaterstoffen, C6, isoalkanen, <5% n-hexaan
EC: 926-605-8
64742-49-0 10-25% ⚠️ Hazardous
n-hexaan
EC: 203-777-6
110-54-3 1-2.5% ⚠️ Hazardous
cyclohexaan
EC: 203-806-2
110-82-7 0.25-1% ⚠️ Hazardous
phenol, 4-methyl-, reaction products with dicyclopentadiene and isobutylene
EC: 271-867-2
68610-51-5 1% ⚠️ Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Bij bewusteloosheid ligging en vervoer in stabiele zijligging.

πŸ–οΈ Skin Contact

Onmiddellijk met water en zeep afwassen en goed naspoelen.

πŸ‘οΈ Eye Contact

Ogen bij geopend ooglid meerdere minuten met stromend water spoelen.

🍽️ Ingestion/Swallowing

Als de klachten niet minderen, een arts raadplegen.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

βœ… Suitable Extinguishing Media

CO2, bluspoeder of waterstraal. Grotere brand met waterstraal bestrijden of met schuim, dat tegen alcohol bestand is.

⚠️ Specific Fire Hazards

Geen verdere relevante informatie verkrijgbaar.

πŸ›‘οΈ Firefighter Protection Equipment

Geen bijzondere maatregelen nodig.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🌍 Environmental Precautions

Mag niet in riolering of afvalwater terechtkomen. Niet in de riolering/het oppervlaktewater/het grondwater laten terechtkomen.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Aerosol
Critical Property
πŸ“Š Physical State Data
Not available
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Not available
🎨 Colour
Volgens de produktbeschrijving
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Aerosol
πŸ‘ƒ Odor
Karakteristiek
πŸ“Š Odor Threshold
Niet bepaald.
πŸ§ͺ Ph
Niet bepaald.
🧊 Melting Point
Niet bepaald.
Critical Property
πŸ’¨ Boiling Point
60 ℃
Critical Property
πŸ”₯ Flash Point
-42 ℃
Critical Property
πŸ“Š Freezing Point
Niet bepaald.
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Niet bruikbaar.
πŸ’¨ Vapor Pressure
5200 hPa
πŸ“Š Vapor Density
Not available
πŸ“Š Relative Density
~0,773 g/cm3
πŸ“Š Bulk Density
Not available
βš–οΈ Density
Not available
πŸ”₯ Flammability
Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting.
πŸ“Š Upper Explosive Limit
18,6 Vol %
πŸ“Š Lower Explosive Limit
0,7 Vol %
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
235 ℃
πŸ“Š Decomposition Temperature
Niet bepaald.
πŸ’§ Solubility
Not available
πŸ“Š Partition Coefficient
Niet bepaald.
πŸ“Š Solubility In Water
Niet resp. gering mengbaar.
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
89,43 %
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Not available
πŸ“Š Kinematic Viscosity
Not available
πŸ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

β€’ Voor goede ventilatie/afzuiging op de werkplaatsen zorgen.

β€’ Nietspuiten in de richting van een vlam of een gloeiend voorwerp.

β€’ Onststekingsbronnen op afstand houden - niet roken.

β€’ Houder onder druk.

β€’ Beschermen tegen de zon en niet blootstellen aan een hogere temperatuur dan 50℃, bijv.

β€’ door gloeilampen.

β€’ Ook na gebruik niet doorboren of verbranden.

πŸͺ Storage Conditions

β€’ Tanks ondoordringbaar gesloten houden.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Geen aanvullende gegevens. Zie 7.

🧀 Hand Protection

Veiligheidshandschoenen. Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Aanbevolen materiaaldikte : > 0,12 mm. Nitrilrubber. Voor het mengsel van de hieronder vermelde chemicalien moet de penetratietijd minstens 10 minuten bedragen (permeatie volgens EN 374 Deel 3: Level 1).

πŸ‘οΈ Eye Protection

Niet noodzakelijk.

😷 Respiratory Protection

Bij onvoldoende ventilatie ademhalingsbescherming. Aanbevolen filter voor kortstondig gebruik: Filter A

🦺 Skin/Body Protection

Draag geschikte beschermende kleding

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

βœ… Chemical Stability

Geen afbraak bij gebruik volgens voorschrift.

βš—οΈ Reactivity

Geen verdere relevante informatie verkrijgbaar.

⚠️ Hazardous Reactions

Geen gevaarlijke reacties bekend.

🚫 Conditions to Avoid

Geen verdere relevante informatie verkrijgbaar.

πŸ§ͺ Incompatible Materials

Geen verdere relevante informatie verkrijgbaar.

πŸ’¨ Hazardous Decomposition Products

Gevaar voor vorming van toxische pyrolyseprodukten.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

🌱 Bioaccumulatie

Geen verdere relevante informatie verkrijgbaar.

🌱 Toxiciteit

Aquatische toxiciteit: Geen verdere relevante informatie verkrijgbaar.

🌱 Persistentie en afbreekbaarheid

Geen verdere relevante informatie verkrijgbaar.

🌱 Mobiliteit in de bodem

Geen verdere relevante informatie verkrijgbaar.

🌱 Resultaten van PBT- en zPzB-beoordeling

PBT: Niet bruikbaar. zPzB: Niet bruikbaar.

🌱 Hormoonontregelende eigenschappen

Het product bevat geen stoffen met hormoonontregelende eigenschappen.

🌱 Andere schadelijke effecten

Opmerking: Giftig voor vissen. Verdere ecologische informatie: Algemene informatie: Gevaar voor water klasse 2 (D) (Zelfclassificatie): gevaar voor water Niet lozen in grondwater, in oppervlaktewater of in riolering. Gevaar voor drinkwater zelfs bij uitlopen van geringe hoeveelheden in de ondergrond. In oppervlaktewater ook giftig voor vissen en plankton. giftig voor in het water levende organismen

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

Afvalverwerkingsmethoden

πŸ—‚οΈ Product Disposal Recommendations

Mag niet tesamen met huisvuil gestort worden of in de riolering terechtkomen. Afvalverwijdering volgens overheidsbepalingen.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

🏷️ UN Number

UN1950

πŸ“¦ Proper Shipping Name

AEROSOLS, flammable

⚠️ Transport Hazard Class

2

πŸ“‹ Packing Group

Niet van toepassing

πŸš› ADR Transport Precautions

Waarschuwing: Gassen - F-D,S-U

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Lijmspray?

The signal word for this substance is "danger".

What is the physical form of Lijmspray?

Lijmspray is a aerosol with volgens de produktbeschrijving color. It has karakteristiek odor.

What is Lijmspray used for?

Kleefstof

What are the hazard statements for Lijmspray?

This substance has 5 hazard statements: H222: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H229: Zeer licht ontvlambare aerosol. Houder onder druk: kan open barsten bij verhitting. H315: Veroorzaakt huidirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken. H411: Giftig voor in het water levende organismen, met langdurige gevolgen.

What is the melting point of Lijmspray?

The melting point is Niet bepaald. and the boiling point is 60 ℃.