NextSDS Logo
NO

NOVA PTFE OIL

NO SIGNAL WORD Vloeistof SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
NOVA PTFE OIL

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Smeerolie
Uses Advised Against
Geen ontraden gebruiken gekend

Overview

NOVA PTFE OIL is a kenmerkende geur substance commonly used smeerolie.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Novatio

undefined

πŸ“

Industrielaan 5B, B-2250 Olen

🌍

BE

πŸ“ž

+32 14 25 76 40

πŸ“ 

+32 14 22 02 66

Novatech International N.V.

manufacturer

πŸ“

Industrielaan 5B, B-2250 Olen

🌍

BE

πŸ“ž

+32 14 85 97 37

πŸ“ 

+32 14 85 97 38

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

BIG

πŸ“ž

+32 14 58 45 45

🌍

BE

πŸ•’

24u/24u

πŸ—£οΈ

Languages: EN, FR, DE, NL

πŸ’‘

Telefonisch advies: Engels, Frans, Duits, Nederlands

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

Dit mengsel bevat geen meldingsplichtige stoffen

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Slachtoffer in de frisse lucht brengen. Bij ademhalingsproblemen, arts/medische dienst raadplegen.

Symptoms:

Geen effecten bekend.

πŸ–οΈ Skin Contact

Indien mogelijk, de chemische stof opdeppen/droog verwijderen. Daarna onmiddellijk spoelen/douchen met (lauw) water.

Symptoms:

Geen effecten bekend.

πŸ‘οΈ Eye Contact

Onmiddellijk spoelen met (lauw) water. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen. Indien de irritatie aanhoudt, arts/medische dienst raadplegen.

Symptoms:

Geen effecten bekend.

🍽️ Ingestion/Swallowing

Mond spoelen met water. Indien men zich onwel voelt, arts/medische dienst raadplegen. Niet wachten op ziekteverschijnselen om een antigifcentrum te raadplegen.

Symptoms:

Geen effecten bekend.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
Vloeistof
Critical Property
πŸ“Š Physical State Data
liquid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Kenmerkende geur
🎨 Colour
Geel
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Not available
πŸ‘ƒ Odor
Kenmerkende geur
πŸ“Š Odor Threshold
Geen gegevens beschikbaar in de literatuur
πŸ§ͺ Ph
Niet van toepassing (niet oplosbaar in water)
🧊 Melting Point
Geen gegevens beschikbaar in de literatuur
Critical Property
πŸ’¨ Boiling Point
> 200 Β°C ; 1013 hPa
Critical Property
πŸ”₯ Flash Point
> 150 ℃
Critical Property
πŸ“Š Freezing Point
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Not available
πŸ’¨ Vapor Pressure
< 1 hPa ; 20 ℃
πŸ“Š Vapor Density
Not available
πŸ“Š Relative Density
0.93; 15 ℃
πŸ“Š Bulk Density
Not available
βš–οΈ Density
932 kg/m3 ; 15 ℃
Critical Property
πŸ”₯ Flammability
Niet ingedeeld als ontvlambaar
πŸ“Š Upper Explosive Limit
Not available
πŸ“Š Lower Explosive Limit
Not available
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
Geen gegevens beschikbaar in de literatuur
πŸ“Š Decomposition Temperature
Geen gegevens beschikbaar in de literatuur
πŸ’§ Solubility
Water ; < 1 g/100 ml
πŸ“Š Partition Coefficient
Niet van toepassing (mengsel)
πŸ“Š Solubility In Water
< 1 g/100 ml
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Geen gegevens beschikbaar in de literatuur
πŸ“Š Kinematic Viscosity
1800 mm2/s ; 25 ℃
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Verwijderd houden van open vuur/warmte. Werken in open lucht/onder plaatselijke afzuiging/met ventilatie of met ademhalingsbescherming.

🧀 Hand Protection

Beschermende handschoenen tegen chemicaliΓ«n (EN 374). Materiaalkeuze: nitrilrubber; Gemeten doorbraaktijd: > 480 minuten; Dikte: 0.4 mm; Beschermingsindex: Klasse 6.

πŸ‘οΈ Eye Protection

Geen oogbescherming vereist bij normaal gebruik.

😷 Respiratory Protection

Geen adembescherming vereist bij normaal gebruik.

🦺 Skin/Body Protection

Beschermende kleding (EN 14605 of EN 13034).

🌍 Environmental Exposure Controls

Zie rubrieken 6.2, 6.3 en 13

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for NOVA PTFE OIL?

The signal word for this substance is "no signal word".

What is the physical form of NOVA PTFE OIL?

NOVA PTFE OIL is a vloeistof appearing as kenmerkende geur with geel color. It has kenmerkende geur odor.

What is the solubility of NOVA PTFE OIL?

Water ; < 1 g/100 ml

What is NOVA PTFE OIL used for?

Smeerolie

What is the melting point of NOVA PTFE OIL?

The melting point is Geen gegevens beschikbaar in de literatuur and the boiling point is > 200 Β°C ; 1013 hPa.