NextSDS Logo
Aq

Aquamarijn LINOTYN

NO SIGNAL WORD SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aquamarijn LINOTYN

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Verdunning

Overview

Aquamarijn LINOTYN commonly used verdunning.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Flam. Liq.
Aquatic Acute
Aquatic Chronic
Skin Sens.
Acute Tox.
Eye Irrit.
Skin Irrit.

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

U.P. Quality & Environment b.v.

manufacturer

Postbus 176 1970 AD IJmuiden

NL

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Nationaal Vergiftigingen Informatie Centrum

+31 (0)30-2748888

NL

Buiten kantooruren, uitsluitend bestemd om artsen te informeren bij accidentele vergiftigingen

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
TERPENTIJNOLIE
EC: 232-350-7
8006-64-2 50-75% Hazardous
D-LIMONEEN
EC: 227-813-5
5989-27-5 25-50% Hazardous

Composition Notes

De volledige R-zinnen zijn te vinden in hoofdstuk 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Persoon in de frisse lucht brengen, warm houden. Patiënt laten rusten. Bij onregelmatige of gestopte ademhaling: kunstmatig beademen. Bij bewusteloosheid: zijligging - arts bellen.

Skin Contact

Verontreinigde kledingstukken onmiddellijk verwijderen. Met water en zeep wassen en goed naspoelen met water.

Eye Contact

Contactlenzen verwijderen, oogleden geopend houden. Royaal met water spoelen (10-15 min.).

Ingestion/Swallowing

Onmiddellijk een arts consulteren. Patiënt laten rusten. Geen braken opwekken.

Immediate Medical Attention Required

Bij twijfel of bij aanhoudende verschijnselen een arts raadplegen. Bij bewusteloosheid: arts bellen. Onmiddellijk een arts consulteren.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solubility In Fat
Not available
Colour Intensity
Not available
Softening Point
Not available
Partition Coefficient
Not available
Flammability
Not available
Boiling Point
Not available
Melting Point
Not available
Auto Ignition Temperature
Not available
Odor Threshold
Not available
Decomposition Temperature
Not available
Colour
Not available
Lower Explosive Limit
Not available
Solubility In Water
Not available
Molecular Weight
Not available
Appearance
Not available
Evaporation Rate
Not available
Ph
Not available
Flash Point
ca. 33 C
Critical Property
Kinematic Viscosity
Not available
Crystallisation Point
Not available
Odor
Not available
Explosive Limits
Not available
Bulk Density
Not available
Cloud Point
Not available
Relative Density
Not available
Relative Evaporation Rate
Not available
Upper Explosive Limit
Not available
Freezing Point
Not available
Vapor Pressure
( 50 C ) hPa
Vapor Density
Not available
State Under Standard Conditions
Not available
Form
Not available
Voc Content
Not available
Dynamic Viscosity
Not available
Properties Status
Not available
Density
( 20 C ) ca. 0,86 g/cm [3]
Critical Property
Metal Corrosion
Not available
Physical State
Not available
Physical State Data
Not available
Solidification Point
Not available
Solubility
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Zorg voor voldoende ventilatie. Waar mogelijk moet dit worden bereikt door middel van het gebruik van de plaatselijke luchtafvoer en een goede ruimtelijke ventilatie. Indien deze niet voldoende zijn om de concentratie van deeltjes en damp van oplosmiddelen onder de grenswaarden te houden, dan dient geschikte ademhalingsbescherming te worden gedragen.

Hand Protection

Tegen oplosmiddelen bestendige veiligheidshandschoenen dragen.

Eye Protection

veiligheidsscherm gebruiken

Respiratory Protection

Bij overschrijding van de grenswaarden op de werkplek moet een voor dit doel toegelaten ademhalingstoestel gedragen worden. Bij spuitapplicatie: verse luchtkap. Overige applicatiemethoden: alleen in goed geventileerde ruimten toepassen. In plaats van een verse luchtkap kan eventueel een gelaatsmasker met een combinatiefilter worden toegepast.

Skin/Body Protection

Personeel dient antistatische kleding te dragen van een natuurlijk materiaal of van een hittebestendig synthetisch materiaal. Na contact dienen alle delen van het lichaam te worden gewassen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1263

Proper Shipping Name

PAINT

Transport Hazard Class

3

Packing Group

III

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Aquamarijn LINOTYN?

The signal word for this substance is "no signal word".

What is Aquamarijn LINOTYN used for?

Verdunning