Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
RIDGID HIGH PERFORMANCE THREAD CUTTING OIL commonly used lubricant for industrial use.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
RIDGE TOOL EUROPE
manufacturer
INTERLEUVENLAAN, RESEARCH PARK, HAASRODE, 3001 LEUVEN, BELGIUM
BE
+32 (0) 16380211
+32 (0) 16380210
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
++49/2947/88100
Office hours
Customer Service
+32 (0) 16380211
BE
Office hours
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Mixture of substances listed below with nonhazardous additions.
Chemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
Zinc dialkyldithiophosphat EC: 270-705-8 | 68476-86-8 | 0.1-0.3% | โ ๏ธ Hazardous |
Petroleum gases, liquefied, sweetened | N/A | 25-50% | โ ๏ธ Hazardous |
Additional Information
For the wording of the listed risk phrases refer to section 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Supply fresh air; consult doctor in case of complaints.
๐๏ธ Skin Contact
Immediately rinse with water.
๐๏ธ Eye Contact
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
๐ฝ๏ธ Ingestion/Swallowing
Rinse out mouth and then drink plenty of water.
Symptoms:
Gastric or intestinal disorders
๐จ Immediate Medical Attention Required
No further relevant information available.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
โ Suitable Extinguishing Media
Foam, Sand, Carbon dioxide, CO2, sand, extinguishing powder.
โ Unsuitable Extinguishing Media
Water with full jet
โ ๏ธ Specific Fire Hazards
During heating or in case of fire poisonous gases are produced.
๐ฅ Fire Fighting Instructions
Cool endangered receptacles with water spray.
๐ก๏ธ Firefighter Protection Equipment
Wear self-contained respiratory protective device.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
๐จ Emergency Procedures
Keep away from ignition sources. Ensure adequate ventilation. Wear protective equipment. Keep unprotected persons away.
๐ Environmental Precautions
Do not allow product to reach sewage system or any water course. Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.
๐งน Cleanup Methods
Dispose of the material collected according to regulations.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
โ ๏ธ Handling Precautions
โข Store in cool, dry place in tightly closed receptacles.
โข Open and handle receptacle with care.
โข Do not spray onto a naked flame or any incandescent material.
โข Keep ignition sources away - Do not smoke.
โข Protect against electrostatic charges.
โข Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50 โ, i.
โข e.
โข electric lights.
โข Do not pierce or burn, even after use.
๐ช Storage Conditions
โข Store in a cool location.
โข Store away from flammable substances.
โข Store away from oxidizing agents.
โข Store away from foodstuffs.
โข Store under lock and key and out of the reach of children.
โข Store in cool, dry conditions in well sealed receptacles.
โข Keep container tightly sealed.
โข Do not seal receptacle gas tight.
โข Protect from heat and direct sunlight.
๐ฅ Fire Prevention Measures
Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
No further data; see item 7.
๐งค Hand Protection
Recommendation: Chemical resistant protective gloves (EN 374). The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
๐๏ธ Eye Protection
Tightly sealed goggles. Use safety glasses according to EN 166 : 2001.
๐ท Respiratory Protection
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Use suitable respiratory protective device in case of insufficient ventilation.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
โ Chemical Stability
No decomposition if used according to specifications.
โ๏ธ Reactivity
Reacts with strong oxidants and strong reducing agents under severe heat.
โ ๏ธ Hazardous Reactions
No dangerous reactions known.
๐ซ Conditions to Avoid
Temperatures above 50 โ can result in breakage of the container.
๐งช Incompatible Materials
No further relevant information available.
๐จ Hazardous Decomposition Products
Emergence of flammable gases / vapors on contact with strong oxidizing agent's possible.
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
๐ฑ Toxicity
๐ฑ Persistence and degradability
๐ฑ Bioaccumulative potential
๐ฑ Mobility in soil
๐ฑ Results of PBT and vPvB assessment
๐ฑ Other adverse effects
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
โป๏ธ Waste Treatment Methods
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
๐๏ธ Product Disposal Recommendations
Disposal must be made according to official regulations.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ท๏ธ UN Number
UN1950
๐ฆ Proper Shipping Name
AEROSOLS, flammable
โ ๏ธ Transport Hazard Class
2
๐ Packing Group
Void
๐ ADR Transport Precautions
Warning: Gases. - F-D,S-U
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
๐ Regulatory Summary
The product has been classified and marked in accordance with EU Directives / Ordinance on Hazardous Materials.
โ Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
โน๏ธ Additional Regulatory Information
Observe the general safety regulations when handling chemicals.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the solubility of RIDGID HIGH PERFORMANCE THREAD CUTTING OIL?
Not miscible or difficult to mix.
What is RIDGID HIGH PERFORMANCE THREAD CUTTING OIL used for?
Lubricant for Industrial use
What is the melting point of RIDGID HIGH PERFORMANCE THREAD CUTTING OIL?
The melting point is Undetermined. and the boiling point is -44 โ.