NextSDS Logo
RI

RIDGID HIGH PERFORMANCE THREAD CUTTING OIL

SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
RIDGID HIGH PERFORMANCE THREAD CUTTING OIL

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Lubricant for Industrial use
Uses Advised Against
No further relevant information available.

Overview

RIDGID HIGH PERFORMANCE THREAD CUTTING OIL commonly used lubricant for industrial use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

N/A

Hazard Classifications

Extremely flammable

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

RIDGE TOOL EUROPE

manufacturer

๐Ÿ“

INTERLEUVENLAAN, RESEARCH PARK, HAASRODE, 3001 LEUVEN, BELGIUM

๐ŸŒ

BE

๐Ÿ“ž

+32 (0) 16380211

๐Ÿ“ 

+32 (0) 16380210

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

++49/2947/88100

๐Ÿ•’

Office hours

Customer Service

๐Ÿ“ž

+32 (0) 16380211

๐ŸŒ

BE

๐Ÿ•’

Office hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mixture of substances listed below with nonhazardous additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Zinc dialkyldithiophosphat
EC: 270-705-8
68476-86-8 0.1-0.3% โš ๏ธ Hazardous
Petroleum gases, liquefied, sweetened N/A 25-50% โš ๏ธ Hazardous

Additional Information

For the wording of the listed risk phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Immediately rinse with water.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse out mouth and then drink plenty of water.

Symptoms:

Gastric or intestinal disorders

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Foam, Sand, Carbon dioxide, CO2, sand, extinguishing powder.

โŒ Unsuitable Extinguishing Media

Water with full jet

โš ๏ธ Specific Fire Hazards

During heating or in case of fire poisonous gases are produced.

๐Ÿ”ฅ Fire Fighting Instructions

Cool endangered receptacles with water spray.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Wear self-contained respiratory protective device.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐Ÿšจ Emergency Procedures

Keep away from ignition sources. Ensure adequate ventilation. Wear protective equipment. Keep unprotected persons away.

๐ŸŒ Environmental Precautions

Do not allow product to reach sewage system or any water course. Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.

๐Ÿงน Cleanup Methods

Dispose of the material collected according to regulations.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Aerosol
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ’จ Boiling Point
-44 โ„ƒ
Critical Property
๐Ÿ”ฅ Flash Point
-60 โ„ƒ
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable.
๐Ÿ’จ Vapor Pressure
0.1 hPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.5 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
9.5 Vol %
๐Ÿ“Š Lower Explosive Limit
0.9 Vol %
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
287 โ„ƒ
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not miscible or difficult to mix.
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Not miscible or difficult to mix.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Store in cool, dry place in tightly closed receptacles.

โ€ข Open and handle receptacle with care.

โ€ข Do not spray onto a naked flame or any incandescent material.

โ€ข Keep ignition sources away - Do not smoke.

โ€ข Protect against electrostatic charges.

โ€ข Pressurized container: protect from sunlight and do not expose to temperatures exceeding 50 โ„ƒ, i.

โ€ข e.

โ€ข electric lights.

โ€ข Do not pierce or burn, even after use.

๐Ÿช Storage Conditions

โ€ข Store in a cool location.

โ€ข Store away from flammable substances.

โ€ข Store away from oxidizing agents.

โ€ข Store away from foodstuffs.

โ€ข Store under lock and key and out of the reach of children.

โ€ข Store in cool, dry conditions in well sealed receptacles.

โ€ข Keep container tightly sealed.

โ€ข Do not seal receptacle gas tight.

โ€ข Protect from heat and direct sunlight.

๐Ÿ”ฅ Fire Prevention Measures

Keep ignition sources away - Do not smoke. Protect against electrostatic charges.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

Recommendation: Chemical resistant protective gloves (EN 374). The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles. Use safety glasses according to EN 166 : 2001.

๐Ÿ˜ท Respiratory Protection

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Use suitable respiratory protective device in case of insufficient ventilation.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

No decomposition if used according to specifications.

โš—๏ธ Reactivity

Reacts with strong oxidants and strong reducing agents under severe heat.

โš ๏ธ Hazardous Reactions

No dangerous reactions known.

๐Ÿšซ Conditions to Avoid

Temperatures above 50 โ„ƒ can result in breakage of the container.

๐Ÿงช Incompatible Materials

No further relevant information available.

๐Ÿ’จ Hazardous Decomposition Products

Emergence of flammable gases / vapors on contact with strong oxidizing agent's possible.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Toxicity

Aquatic toxicity: No further relevant information available.

๐ŸŒฑ Persistence and degradability

No further relevant information available.

๐ŸŒฑ Bioaccumulative potential

No further relevant information available.

๐ŸŒฑ Mobility in soil

No further relevant information available.

๐ŸŒฑ Results of PBT and vPvB assessment

PBT: Not applicable. vPvB: Not applicable.

๐ŸŒฑ Other adverse effects

No further relevant information available.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

โ™ป๏ธ Waste Treatment Methods

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

๐Ÿ—‚๏ธ Product Disposal Recommendations

Disposal must be made according to official regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1950

๐Ÿ“ฆ Proper Shipping Name

AEROSOLS, flammable

โš ๏ธ Transport Hazard Class

2

๐Ÿ“‹ Packing Group

Void

๐Ÿš› ADR Transport Precautions

Warning: Gases. - F-D,S-U

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

๐Ÿ“‹ Regulatory Summary

The product has been classified and marked in accordance with EU Directives / Ordinance on Hazardous Materials.

โŒ Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

โ„น๏ธ Additional Regulatory Information

Observe the general safety regulations when handling chemicals.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the solubility of RIDGID HIGH PERFORMANCE THREAD CUTTING OIL?

Not miscible or difficult to mix.

What is RIDGID HIGH PERFORMANCE THREAD CUTTING OIL used for?

Lubricant for Industrial use

What is the melting point of RIDGID HIGH PERFORMANCE THREAD CUTTING OIL?

The melting point is Undetermined. and the boiling point is -44 โ„ƒ.