NextSDS Logo
Ki

Kilfrost Cooltrans Plus CTL

NO SIGNAL WORD Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Kilfrost Cooltrans Plus CTL

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Heat transfer fluid. Restricted to professional users.
Uses Advised Against
None known.

Overview

Kilfrost Cooltrans Plus CTL commonly used heat transfer fluid. restricted to professional users..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Not applicable.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Kilfrost Limited

global supplier

๐Ÿ“

Albion Works Haltwhistle NE49 OHJ Northumberland ENGLAND

๐ŸŒ

GB

๐Ÿ“ž

+44 (01434) 320332

๐Ÿ“ 

+44 (01434) 321463

Kilfrost Limited

manufacturer

๐Ÿ“

Albion Works Haltwhistle NE49 OHJ Northumberland ENGLAND

๐ŸŒ

GB

๐Ÿ“ž

+44 (01434) 320332

๐Ÿ“ 

+44 (01434) 321463

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

NHS

๐Ÿ“ž

111

๐ŸŒ

GB

๐Ÿ’ก

In the event of a medical enquiry involving this product

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Monopropylene Glycol
EC: 200-338-0
57-55-6 60-100% โœ“ Non-hazardous

Additional Information

According to REACH Regulation (EC) No 1907/2006, as retained and amended SI 2019/758 and SI 2020/1577

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

In case of discomfort: bring the person into fresh air.

Symptoms:

discomfort

๐Ÿ–๏ธ Skin Contact

Upon irritation: rinse with water. In the event of continued irritation, seek medical assistance.

Symptoms:

irritation

๐Ÿ‘๏ธ Eye Contact

If in eyes: Flush eyes with plenty of water or salt water (20-30 C) and continue until irritation stops. Remove contact lenses.

Symptoms:

irritation

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse and flush mouth thoroughly and consume large quantities of water. In case of continued discomfort: seek medical assistance and bring this safety data sheet.

Symptoms:

discomfort

๐Ÿšจ Immediate Medical Attention Required

Treat symptomatically.

Medical Treatment

Treat symptomatically. Bring this safety data sheet or the label from this product.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Clear
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
8.3 - 9.5
๐ŸงŠ Melting Point
Testing not relevant or not possible due to the nature of the product.
Critical Property
๐Ÿ’จ Boiling Point
~151 @ 1013 mbar
Critical Property
๐Ÿ”ฅ Flash Point
~108 COC (Cleveland open cup).
Critical Property
๐Ÿ“Š Freezing Point
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Softening Point
Does not apply to liquids.
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
1.03 based on raw material (20 C)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
Completely soluble
๐Ÿ“Š Solubility In Fat
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
51.8 mm/s (20 C)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Apply standard precautions during use of the product. Avoid inhalation of vapours.

๐Ÿงค Hand Protection

Nitrile gloves with a thickness of 0.2 mm and a breakthrough time of 240 minutes. Standards: EN374-2, EN374-3, EN388.

๐Ÿ‘๏ธ Eye Protection

Face shield alternatively safety glasses with side shields. Standard: EN166.

๐Ÿ˜ท Respiratory Protection

Respiratory protection is not needed in the event of adequate ventilation.

๐Ÿฆบ Skin/Body Protection

Dedicated work clothing should be worn. Wear a protective suit in the event of prolonged periods of work with the product.

๐ŸŒ Environmental Exposure Controls

No specific requirements.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Kilfrost Cooltrans Plus CTL?

The signal word for this substance is "no signal word".

What is the physical form of Kilfrost Cooltrans Plus CTL?

Kilfrost Cooltrans Plus CTL is a liquid with clear color.

What is Kilfrost Cooltrans Plus CTL used for?

Heat transfer fluid. Restricted to professional users.

What is the melting point of Kilfrost Cooltrans Plus CTL?

The melting point is Testing not relevant or not possible due to the nature of the product. and the boiling point is ~151 @ 1013 mbar.