Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
HyGold Atlas L500 commonly used metalworking fluids, industrial lubricants, grease manufacturing, hydraulic oils, gear oils, heavy duty engine oil, bar & chain, carriers & diluents, engine oil..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Ergon, Inc.
manufacturer
P.O. Box 1639 Jackson, MS 39215
US
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Customer service
1-800-222-7122
US
CHEMTREC
1-800-424-9300
US
After Business Hours
North America Only
CHEMTREC
1-703-527-3887
US
After Business Hours
International
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
Distillates (petroleum), hydrotreated heavy naphthenic EC: 265-155-0 | 64742-52-5 | 100% | โ Non-hazardous |
Composition Notes
Note L - Not classified as a carcinogen. Meets EU requirement of less than 3% (w/w) DMSO extract for total polycyclic aromatic compound (PAC) using IP 346.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move to fresh air. Oxygen or artificial respiration if needed. IF exposed or concerned: Get medical advice/attention.
๐๏ธ Skin Contact
Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If skin irritation or an allergic skin reaction develops, get medical attention.
Symptoms:
Defatting of the skin. Skin irritation or an allergic skin reaction.
๐๏ธ Eye Contact
Flush thoroughly with water. If irritation occurs, get medical assistance.
Symptoms:
Irritation.
๐ฝ๏ธ Ingestion/Swallowing
Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Call a poison control centre immediately.
๐จ Immediate Medical Attention Required
IF exposed or concerned: Get medical advice/attention (for inhalation). If irritation occurs, get medical assistance (for eye contact). If skin irritation or an allergic skin reaction develops, get medical attention (for skin contact). Call a poison control centre immediately (for ingestion).
Medical Treatment
Treat symptomatically.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Adequate ventilation should be provided whenever the material is heated or mists are generated. Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.
๐งค Hand Protection
Wear suitable gloves tested to EN374. Chemical resistant gloves are recommended. If contact with forearms is likely wear gauntlet style gloves. When prolonged or frequent repeated contact occurs, Nitrile gloves may be suitable. (Breakthrough time of > 240 minutes.) For incidental contact/splash protection Neoprene, PVC gloves may be suitable.
๐๏ธ Eye Protection
Goggles/face shield are recommended. Eye protection should meet standard EN 166.
๐ท Respiratory Protection
Under normal conditions, respirator is not normally required. No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [boiling point >65 C (149 F)] meeting EN14387.
๐ฆบ Skin/Body Protection
Chemical/oil resistant clothing is recommended. Launder contaminated clothing before reuse.
๐ Environmental Exposure Controls
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for HyGold Atlas L500?
The signal word for this substance is "no signal word".
What is the physical form of HyGold Atlas L500?
HyGold Atlas L500 is a liquid. with light amber to golden color. It has mild petroleum odor odor.
What is HyGold Atlas L500 used for?
Metalworking Fluids, Industrial Lubricants, Grease Manufacturing, Hydraulic Oils, Gear Oils, Heavy Duty Engine Oil, Bar & Chain, Carriers & Diluents, Engine Oil.
What is the melting point of HyGold Atlas L500?
The melting point is -31 C (-23,8 F) ASTM D5950/ISO 3016 and the boiling point is 323 C (613,4 F) ASTM D2887/ ISO 3294.