Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
HyGold L500 commonly used metalworking fluids, industrial lubricants, grease manufacturing, hydraulic oils, gear oils, heavy duty engine oil, bar & chain, carriers & diluents, engine oil..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Ergon, Inc.
manufacturer
P.O. Box 1639 Jackson, MS 39181 USA
US
Ergon International, Inc.
undefined
Drve Richelle 161 Building C B-1410 Waterloo, Belgium
BE
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
US Customer Service
+ 1-800-222-7122
US
CHEMTREC
+ 1-800-424-9300
US
After Business Hours
North America
CHEMTREC
+ 1-703-527.-3887
US
International
CHEMTREC
+32-28083237
BE
Belgium
CHEMTREC
+33-975181407
FR
France
CHEMTREC
+49-69643508409
DE
Germany
CHEMTREC
+39-0245557031
IT
Italy
CHEMTREC
+34-931768545
ES
Spain
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
substanceGeneral Composition
A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces finished oil with a viscosity near 500 SUS at 100F.
Chemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
Distillates (petroleum), hydrotreated heavy naphthenic EC: 265-155-0 | 64742-52-5 | 100% | โ Non-hazardous |
Composition Notes
Note L - Not classified as a carcinogen. Meets EU requirement of less than 3% (w/w) DMSO extract for total polycyclic aromatic compound (PAC) using IP 346.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Move to fresh air. Oxygen or artificial respiration if needed. IF exposed or concerned: Get medical advice/attention.
๐๏ธ Skin Contact
Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If skin irritation or an allergic skin reaction develops, get medical attention.
Symptoms:
Defatting of the skin, irritation, redness, discomfort, or an allergic skin reaction.
๐๏ธ Eye Contact
Flush thoroughly with water. If irritation occurs, get medical assistance.
Symptoms:
Irritation, redness, or discomfort.
๐ฝ๏ธ Ingestion/Swallowing
Rinse mouth with water. Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Call a poison control centre immediately.
Symptoms:
Vomiting, risk of aspiration.
๐จ Immediate Medical Attention Required
Get medical advice/attention if exposed or concerned (inhalation), if eye irritation occurs, or if skin irritation/allergic skin reaction develops. Call a poison control centre immediately for ingestion.
Medical Treatment
Treat symptomatically.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Adequate ventilation should be provided whenever the material is heated or mists are generated. Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.
๐งค Hand Protection
Chemical resistant gloves are recommended. If contact with forearms is likely wear gauntlet style gloves.
๐๏ธ Eye Protection
Goggles/face shield are recommended. Eye protection should meet standard EN 166.
๐ท Respiratory Protection
Under normal conditions, respirator is not normally required. In case of inadequate ventilation and work of brief duration, use suitable respiratory equipment.
๐ฆบ Skin/Body Protection
Chemical/oil resistant clothing is recommended. Launder contaminated clothing before reuse.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for HyGold L500?
The signal word for this substance is "no signal word".
What is the physical form of HyGold L500?
HyGold L500 is a liquid. with light amber to golden color. It has mild petroleum odor odor.
What is the solubility of HyGold L500?
Insoluble
What is HyGold L500 used for?
Metalworking Fluids, Industrial Lubricants, Grease Manufacturing, Hydraulic Oils, Gear Oils, Heavy Duty Engine Oil, Bar & Chain, Carriers & Diluents, Engine Oil.
What is the melting point of HyGold L500?
The melting point is -31 C (-23,8 F) ASTM D5950/ISO 3016 and the boiling point is 323 C (613,4 F) ASTM D2887/ ISO 3294.