NextSDS Logo
Hy

HyPrint 500

NO SIGNAL WORD Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
HyPrint 500
Product Code
649-465-00-7

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Pigments; Printing Inks

Overview

HyPrint 500 commonly used pigments; printing inks.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Ergon, Inc.

manufacturer

๐Ÿ“

P.O. Box 1639 Jackson, MS 39181 USA

๐ŸŒ

US

Ergon International, Inc.

undefined

๐Ÿ“

Drve Richelle 161 Building C B-1410 Waterloo, Belgium

๐ŸŒ

BE

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Ergon, Inc.

๐Ÿ“ž

+ 1-800-222-7122

๐ŸŒ

US

๐Ÿ’ก

US Customer Service

CHEMTREC

๐Ÿ“ž

+ 1-800-424-9300

๐ŸŒ

US

๐Ÿ•’

After Business Hours

๐Ÿ’ก

North America

CHEMTREC

๐Ÿ“ž

+ 1-703-527.-3887

๐ŸŒ

US

๐Ÿ’ก

International

CHEMTREC

๐Ÿ“ž

+32-28083237

๐ŸŒ

BE

๐Ÿ’ก

Belgium

CHEMTREC

๐Ÿ“ž

+33-975181407

๐ŸŒ

FR

๐Ÿ’ก

France

CHEMTREC

๐Ÿ“ž

+49-69643508409

๐ŸŒ

DE

๐Ÿ’ก

Germany

CHEMTREC

๐Ÿ“ž

+39-0245557031

๐ŸŒ

IT

๐Ÿ’ก

Italy

CHEMTREC

๐Ÿ“ž

+34-931768545

๐ŸŒ

ES

๐Ÿ’ก

Spain

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Substances

General Composition

HyPrint 500 - Ergon International SDS EU

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy naphthenic
EC: 265-155-0
64742-52-5 100% โœ“ Non-hazardous

Composition Notes

Not classified as a carcinogen. Meets EU requirement of less than 3% (w/w) DMSO extract for total polycyclic aromatic compound (PAC) using IP 346. Note L

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air. Oxygen or artificial respiration if needed. IF exposed or concerned: Get medical advice/attention.

๐Ÿ–๏ธ Skin Contact

Wash contact areas with soap and water. Remove contaminated clothing. Launder contaminated clothing before reuse. If skin irritation or an allergic skin reaction develops, get medical attention.

๐Ÿ‘๏ธ Eye Contact

Flush thoroughly with water. If irritation occurs, get medical assistance.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Call a poison control centre immediately.

๐Ÿšจ Immediate Medical Attention Required

Contact physician if discomfort continues. If exposed or concerned, get medical advice/attention. If skin irritation or an allergic skin reaction develops, get medical attention. If eye irritation occurs, get medical assistance. Call a poison control centre immediately.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Light Amber to Golden
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid.
๐Ÿ‘ƒ Odor
Mild Petroleum Odor
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Property has not been measured.
๐ŸงŠ Melting Point
-31 C (-23,8 F) ASTM D5950/ISO 3016
Critical Property
๐Ÿ’จ Boiling Point
323 C (613,4 F) ASTM D2887/ ISO 3294
Critical Property
๐Ÿ”ฅ Flash Point
- 200,0 C (> 392,0 F) Cleveland open cup ASTM D92/ ISO 2592
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Property has not been measured.
๐Ÿ“Š Vapor Density
- 5
๐Ÿ“Š Relative Density
0,92 (15,56 C (60 F) ASTM D4052/ ISO 12185)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Will burn if involved in a fire.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 315,56 C (> 600 F) ASTM E659
๐Ÿ“Š Decomposition Temperature
Property has not been measured.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not established.
๐Ÿ“Š Solubility In Water
Insoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
>= 38,1 mm/s
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Adequate ventilation should be provided whenever the material is heated or mists are generated. Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.

๐Ÿงค Hand Protection

Wear suitable gloves tested to EN374. Chemical resistant gloves are recommended. If contact with forearms is likely wear gauntlet style gloves. When prolonged or frequent repeated contact occurs, Nitrile gloves may be suitable. (Breakthrough time of > 240 minutes.) For incidental contact/splash protection Neoprene, PVC gloves may be suitable.

๐Ÿ‘๏ธ Eye Protection

Goggles/face shield are recommended. Eye protection should meet standard EN 166.

๐Ÿ˜ท Respiratory Protection

Under normal conditions, respirator is not normally required. No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for combined particulate/organic gases and vapours [boiling point >65 C (149 F)] meeting EN14387.

๐Ÿฆบ Skin/Body Protection

Chemical/oil resistant clothing is recommended. Launder contaminated clothing before reuse.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for HyPrint 500?

The signal word for this substance is "no signal word".

What is the physical form of HyPrint 500?

HyPrint 500 is a liquid. with light amber to golden color. It has mild petroleum odor odor.

What is HyPrint 500 used for?

Pigments; Printing Inks

What is the melting point of HyPrint 500?

The melting point is -31 C (-23,8 F) ASTM D5950/ISO 3016 and the boiling point is 323 C (613,4 F) ASTM D2887/ ISO 3294.