NextSDS Logo
DO

DOWSIL R1-9331 Int

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DOWSIL R1-9331 Int

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Intermediate

Overview

DOWSIL R1-9331 Int commonly used intermediate.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

DOW EUROPE GMBH

global supplier

๐Ÿ“

BACHTOBELSTRASSE 4 8810 HORGEN SWITZERLAND

๐ŸŒ

CH

๐Ÿ“ž

31 115 67 2626

DOW BENELUX B.V.

national supplier

๐Ÿ“

HERBERT H.DOWWEG 5 HOEK 4542 NM TERNEUZEN NETHERLANDS

๐ŸŒ

NL

๐Ÿ“ž

(31) 115 67 2626

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

00 41 447 28 2820

๐ŸŒ

CH

๐Ÿ•’

24-Hour

Emergency Contact

๐Ÿ“ž

00 32 3575 0330

๐ŸŒ

BE

Belgium Poison Center

๐Ÿ“ž

070/245.245

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Polydimethylsiloxane hydroxy-terminated
EC: Polymer
70131-67-8 Not specified โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move person to fresh air and keep comfortable for breathing; consult a physician.

๐Ÿ–๏ธ Skin Contact

Wash off with plenty of water.

๐Ÿ‘๏ธ Eye Contact

Flush eyes thoroughly with water for several minutes. Remove contact lenses after the initial 1-2 minutes and continue flushing for several additional minutes. If effects occur, consult a physician, preferably an ophthalmologist.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth with water. No emergency medical treatment necessary.

๐Ÿšจ Immediate Medical Attention Required

No specific antidote. Treatment of exposure should be directed at the control of symptoms and the clinical condition of the patient.

Medical Treatment

Treatment of exposure should be directed at the control of symptoms and the clinical condition of the patient.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colorless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Odorless
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No data available
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
- 35 C
Critical Property
๐Ÿ”ฅ Flash Point
>180 C
Critical Property
๐Ÿ“Š Freezing Point
not determined
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
< 1
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
0,98
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Ignitable (see flash point)
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
385 C
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
not determined
๐Ÿ“Š Solubility In Water
not determined
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
No data available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not corrosive to metals
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
70 cSt at 25 C
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use local exhaust ventilation, or other engineering controls to maintain airborne levels below exposure limit requirements or guidelines. If there are no applicable exposure limit requirements or guidelines, general ventilation should be sufficient for most operations. Local exhaust ventilation may be necessary for some operations.

๐Ÿงค Hand Protection

Chemical protective gloves should not be needed when handling this material. Consistent with general hygienic practice for any material, skin contact should be minimized.

๐Ÿ‘๏ธ Eye Protection

Use safety glasses (with side shields). Safety glasses (with side shields) should be consistent with EN 166 or equivalent.

๐Ÿ˜ท Respiratory Protection

Respiratory protection should be worn when there is a potential to exceed the exposure limit requirements or guidelines. If there are no applicable exposure limit requirements or guidelines, wear respiratory protection when adverse effects, such as respiratory irritation or discomfort have been experienced, or where indicated by your risk assessment process. For most conditions, no respiratory protection should be needed; however, if material is heated or sprayed, use an approved air-purifying respirator. Use the following CE approved air-purifying respirator: Organic vapor cartridge with a particulate pre-filter, type AP2 (meeting standard EN 14387).

๐Ÿฆบ Skin/Body Protection

No precautions other than clean body-covering clothing should be needed.

๐ŸŒ Environmental Exposure Controls

See SECTION 7: Handling and storage and SECTION 13: Disposal considerations for measures to prevent excessive environmental exposure during use and waste disposal.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DOWSIL R1-9331 Int?

The signal word for this substance is "no signal word".

What is the physical form of DOWSIL R1-9331 Int?

DOWSIL R1-9331 Int is a liquid with colorless color. It has odorless odor.

What is DOWSIL R1-9331 Int used for?

Intermediate

What is the melting point of DOWSIL R1-9331 Int?

The melting point is No data available and the boiling point is - 35 C.