NextSDS Logo
WA

WANOL F3147D

NO SIGNAL WORD liquid (at 20 C, 1013 hPa) SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
WANOL F3147D

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Component for production of polyurethanes
Uses Advised Against
Do not use for private purposes (household).

Overview

WANOL F3147D commonly used component for production of polyurethanes.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Wanhua Chemical (Singapore) Pte.Ltd.

global supplier

๐Ÿ“

50 Raffles Place#33-06, Singapore Land Tower 48623 Singapore

๐ŸŒ

SG

๐Ÿ“ž

+65 62240614; +65 62240615

BorsodChem Zrt.

undefined

๐Ÿ“

H-3700 Kazincbarcika Bolyai tr 1 Hungary

๐ŸŒ

HU

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

SGS Emergency Response Services

๐Ÿ“ž

+32 3 575 55 55

๐ŸŒ

BE

๐Ÿ•’

0-24 h

๐Ÿ—ฃ๏ธ

Languages: EN

๐Ÿ’ก

International

Wanhua

๐Ÿ“ž

+86 535-8203123

๐ŸŒ

CN

๐Ÿ—ฃ๏ธ

Languages: ZH, EN

Emergency Contact

๐Ÿ“ž

+86-532-83889090

๐ŸŒ

CN

๐Ÿ—ฃ๏ธ

Languages: ZH, EN

National Poisons Information Service (England, Wales)

๐Ÿ“ž

111

๐ŸŒ

GB

๐Ÿ•’

0-24 h

BorsodChem Zrt.

๐Ÿ“ž

+36 48 511 211

๐ŸŒ

HU

๐Ÿ•’

0-24 h

๐Ÿ—ฃ๏ธ

Languages: HU, EN

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Glycerol, ethoxylated and propoxylated
EC: 618-655-1
9082-00-2 100% โœ“ Non-hazardous

Composition Notes

In accordance with Article 2 (9) of REACH polymers should be exempted from the general obligation to register.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If symptoms are experienced, remove source of contaminated or move victim to the fresh air. If symptoms persist, get medical attention.

๐Ÿ–๏ธ Skin Contact

Wash affected areas thoroughly with soap and water. If irritation develops and persists, obtain medical advice.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with running water for a minimum of 15 minutes. Hold eyelids open during flushing. If irritation persists, repeat flushing. Obtain medical attention immediately.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting unless directed to do so by medical personnel. Provided the patient is conscious, wash out mouth with water then give 1 or 2 glasses of water to drink. Refer person to medical personnel for immediate attention.

๐Ÿšจ Immediate Medical Attention Required

Refer person to medical personnel for immediate attention. Obtain medical attention immediately. Depending on the degree of exposure, periodic medical examination is suggested.

Medical Treatment

No specific antidote supportive care. Treatment based on judgment of the physician in response to reactions of the patient.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Foam, CO 2, dry powder, water fog or fine spray. Alcohol resistant foams (ATC type) are preferred if available. General purpose synthetic foams (including AFFF) or protein foams may function, but much less effective.

โŒ Unsuitable Extinguishing Media

Strong water stream.

โš ๏ธ Specific Fire Hazards

Carbon oxides (CO, CO 2 ), nitrogen oxides (NO, NO 2 etc.), hydrocarbons can be released in case of fire.

๐Ÿ”ฅ Fire Fighting Instructions

In the event of fire and/or explosion do not breathe fumes. Isolate fire area and deny unnecessary entry. Fire in vicinity poses risk of pressure build-up and rupture. Containers at risk from fire should be cooled with water and, if possible, removed from the danger area.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Safety boots, gloves, safety helmet and protective clothing should be worn.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid (at 20 C, 1013 hPa)
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
slight
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
5.0-8.0
๐ŸงŠ Melting Point
No data.
Critical Property
๐Ÿ’จ Boiling Point
287.6 C
Critical Property
๐Ÿ”ฅ Flash Point
208 C
Critical Property
๐Ÿ“Š Freezing Point
No data.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
No data.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
0.95-1.15
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.95-1.15
Critical Property
๐Ÿ”ฅ Flammability
Not flammable.
๐Ÿ“Š Upper Explosive Limit
No data.
๐Ÿ“Š Lower Explosive Limit
No data.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
>220 C
๐Ÿ“Š Decomposition Temperature
No data.
๐Ÿ’ง Solubility
Water: Partly miscible. Polar and non-polar solvents: No data.
๐Ÿ“Š Partition Coefficient
No data.
๐Ÿ“Š Solubility In Water
Partly miscible.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
No data.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide suitable exhaust ventilation at the processing machines. Use local exhaust ventilation. Enclose the process.

๐Ÿงค Hand Protection

Chemical resistant protective gloves. Examples of gloves materials that might provide suitable protection include: butyl rubber.

๐Ÿ‘๏ธ Eye Protection

Closed safety glasses with side-shields (frame goggles).

๐Ÿ˜ท Respiratory Protection

For most conditions, no respiratory protection is needed. If handling at elevated temperature without sufficient ventilation or in presence of aerosols, use breathing apparatus, full face mask respirator. Respirators type protection can be used in combination with an organic vapour filter type A.

๐Ÿฆบ Skin/Body Protection

Safety shoes and closed work clothing.

๐ŸŒ Environmental Exposure Controls

In accordance with local and national regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for WANOL F3147D?

The signal word for this substance is "no signal word".

What is the physical form of WANOL F3147D?

WANOL F3147D is a liquid (at 20 c, 1013 hpa) with colourless color. It has slight odor.

What is the solubility of WANOL F3147D?

Water: Partly miscible. Polar and non-polar solvents: No data.

What is WANOL F3147D used for?

Component for production of polyurethanes

What is the melting point of WANOL F3147D?

The melting point is No data. and the boiling point is 287.6 C.