NextSDS Logo
Au

Aurora RB Z1

NO SIGNAL WORD Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aurora RB Z1

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
For industrial use only.

Overview

Aurora RB Z1 commonly used for industrial use only..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (None.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Ergon, Inc.

manufacturer

๐Ÿ“

P.O. Box 1639 Jackson, MS 39181 USA

๐ŸŒ

US

Ergon International, Inc.

distributor

๐Ÿ“

Drve Richelle 161 Building C B-1410 Waterloo, Belgium

๐ŸŒ

BE

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

US Customer Service

๐Ÿ“ž

+ 1-800-222-7122

๐ŸŒ

US

CHEMTREC

๐Ÿ“ž

+ 1-800-424-9300

๐ŸŒ

US

๐Ÿ•’

After Business Hours

๐Ÿ’ก

North America

CHEMTREC

๐Ÿ“ž

+ 1-703-527.-3887

๐ŸŒ

US

๐Ÿ’ก

International

CHEMTREC

๐Ÿ“ž

+32-28083237

๐ŸŒ

BE

๐Ÿ’ก

Belgium

CHEMTREC

๐Ÿ“ž

+33-975181407

๐ŸŒ

FR

๐Ÿ’ก

France

CHEMTREC

๐Ÿ“ž

+49-69643508409

๐ŸŒ

DE

๐Ÿ’ก

Germany

CHEMTREC

๐Ÿ“ž

+39-0245557031

๐ŸŒ

IT

๐Ÿ’ก

Italy

CHEMTREC

๐Ÿ“ž

+34-931768545

๐ŸŒ

ES

๐Ÿ’ก

Spain

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
RAPE OIL, OXIDIZED
EC: 305-871-3
95193-59-2 / 68554-11-0 100% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing. Call a physician if symptoms develop or persist.

Symptoms:

symptoms develop or persist

๐Ÿ–๏ธ Skin Contact

Gently wash with plenty of soap and water. Wash contaminated clothing before reuse. Get medical attention if irritation develops and persists.

Symptoms:

irritation develops and persists

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.

Symptoms:

irritation develops and persists

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Do NOT induce vomiting. If vomiting occurs naturally, have victim lean forward to reduce risk of aspiration. Get medical attention if symptoms occur.

Symptoms:

symptoms occur

๐Ÿšจ Immediate Medical Attention Required

Treat symptomatically.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Yellow
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid.
๐Ÿ‘ƒ Odor
Not available.
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available.
๐ŸงŠ Melting Point
-49 - -1 C (-56,2 - 30,2 F)
Critical Property
๐Ÿ’จ Boiling Point
>= 350 C (>= 662 F)
Critical Property
๐Ÿ”ฅ Flash Point
188,0 C (370,4 F) Pensky-Martens Closed Cup
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
0,00000001 Pa @20C
๐Ÿ“Š Vapor Density
Not available.
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,96 g/ml @20C
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
420 C (788 F)
๐Ÿ“Š Decomposition Temperature
350 C (662 F)
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
- 6 @20 C
๐Ÿ“Š Solubility In Water
<= 0,1 mg/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
0,07 - 15 Pas @20C
๐Ÿ“Š Kinematic Viscosity
Not available.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide adequate ventilation, including appropriate local extraction, to ensure that the defined occupational exposure limit is not exceeded.

๐Ÿงค Hand Protection

Wear appropriate chemical resistant gloves.

๐Ÿ‘๏ธ Eye Protection

Wear safety glasses with side shields (or goggles).

๐Ÿ˜ท Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment.

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Aurora RB Z1?

The signal word for this substance is "no signal word".

What is the physical form of Aurora RB Z1?

Aurora RB Z1 is a liquid. with yellow color. It has not available. odor.

What is Aurora RB Z1 used for?

For industrial use only.

What is the melting point of Aurora RB Z1?

The melting point is -49 - -1 C (-56,2 - 30,2 F) and the boiling point is >= 350 C (>= 662 F).