NextSDS Logo
Safety Data Sheet EN

ZIC VEGA DS LX

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ZIC VEGA DS LX

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Hydraulic fluid

Uses advised against

Not available

Manufacturers & Suppliers

S

SK Lubricants Co., Ltd.

manufacturer

26, Jong-ro, Jongno-gu, Seoul, Korea

Emergency Contacts

Emergency Contact

1899-1147

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic 64742-54-7 96 - 99% No
Additive mixture-1 --- 0.5 - 1.5% No
Additive mixture-2 --- 0.5 - 2.5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

When exposed to large amounts of steam and mist, move to fresh air. Take specific treatment if needed.

Skin contact

Flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Laundering enough contaminated clothing before reuse.

Eye contact

Do not rub your eyes. Immediately flush eyes with plenty of water for at least 15 minutes and call a doctor/physician.

Ingestion

About whether I should induce vomiting. Take the advice of a doctor. Rinse your mouth with water immediately.

Immediate Medical Attention

Notify medical personnel of contaminated situations and have them take appropriate protective measures.

Medical Treatment

Take specific treatment if needed.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical, carbon dioxide, regular foam extinguishing agent, spray

Unsuitable media

Avoid use of water jet for extinguishing

Specific hazards

Not available

Instructions

Notify your local firestation and inform the location of the fire and characteristics hazard. Using a unattended and water devices in case of large fire and leave alone to burn if you do not imperative. Use appropriate extinguishing measure suitable for surrounding fire. Keep containers cool with water spray.

Firefighter Protection

Avoid inhalation of materials or combustion by-products. Do not access if the tank on fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Must work against the wind, let the upwind people to evacuate. Move container to safe area from the leak area. Do not direct water at spill or source of leak.

Small spill

sand or other non-combustible material, please let use absorption.

Large spill

Stay upwind and keep out of low areas. Dike for later disposal.

Environmental

Prevent runoff and contact with waterways, drains or sewers.

Cleanup methods

Wipe off the solvent.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wash thoroughly after handling. Avoid direct physical contact. Avoid contact with incompatible materials. Refer to Engineering controls and personal protective equipment. Do not inhale the steam prolonged or repeated.

Storage

Do not use damaged containers. Do not apply direct heat. Save applicable laws and regulations. Avoid direct sunlight. Keep in the original container.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

A system of local and/or general exhaust is recommended to keep employee exposures above the Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. The use of local exhaust ventilation is recommended to control emissions near the source.

Hands

Wear appropriate glove.

Eyes

Wear primary eye protection such as splash resistant safety goggles with a secondary protection face shield.

Respiratory

Under conditions of frequent use or heavy exposure, Respiratory protection may be needed. Respiratory protection is ranked in order from minimum to maximum. Consider warning properties before use. Any chemical cartridge respirator with organic vapor cartridge(s). Any chemical cartridge respirator with a full facepiece and organic vapor cartridge(s). Any air-purifying respirator with a full facepiece and an organic vapor canister. For Unknown Concentration or Immediately Dangerous to Life or Health: Any supplied-air respirator with full facepiece and operated in a pressure-demand or other positive-pressure mode in combination with a separate escape supply. Any self-contained breathing apparatus with a full facepiece.

Skin/Body

Wear appropriate clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Appearance
Liquid, Colorless and transparent
Solubility In Fat
---
Upper Explosive Limit
Not available
Boiling Point
300 °C ~ 580 °C
Crystallisation Point
---
Melting Point
Not available
Solubility In Water
---
Explosive Limits
---
Flammability
Not available
Lower Explosive Limit
Not available
Freezing Point
---
Vapor Density
≥ 5 (Air = 1)
Relative Evaporation Rate
---
State Under Standard Conditions
---
Dynamic Viscosity
---
Form
---
Cloud Point
---
Odor
Mild mineral oil odor
Auto Ignition Temperature
260 ~ 371 °C
Solidification Point
---
Relative Density
0.845 (Water = 1) (15 °C)
Decomposition Temperature
Not available
Metal Corrosion
---
Properties Status
---
Kinematic Viscosity
43.7 ~ 48.3 cSt (40 °C)
Physical State Data
liquid
Colour Intensity
---
Molecular Weight
---
Evaporation Rate
Not available
Softening Point
---
Colour
Colorless and transparent
Solubility
Practically insoluble
Physical State
Liquid
Vapor Pressure
≤ 0.1 kPa (20 °C)
Bulk Density
---
Odor Threshold
Not available
Density
---
Partition Coefficient
log Pow = 3.9 ~ 6
Flash Point
≥ 220 °C
Ph
Not available
Voc Content
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is stable under recommended storage and handling conditions.

Hazardous reactions

Hazardous Polymerization will not occur.

Avoid

Avoid contact with incompatible materials and condition. Avoid: Accumulation of electrostatic charges, Heating, Flames and hot surfaces

Incompatible

Not available

Decomposition

May emit flammable vapour if involved in fire.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

reduction or stabilization by incineration or similar process; Water separation process; evaporation and concentration; agglomeration and precipitation; Separation, distillation, extraction, filtration, pyrolysis

Disposal

The user of this product must disposal by oneself or entrust to waste disposer or person who other's waste recycle and dispose, person who establish and operate waste disposal facilities.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Local transport follows in accordance with Dangerous goods Safety Management Law. Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.

IMDG

Local transport follows in accordance with Dangerous goods Safety Management Law. Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.

IATA

Local transport follows in accordance with Dangerous goods Safety Management Law. Package and transport follow in accordance with Department of Transportation (DOT) and other regulatory agency requirements.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ZIC VEGA DS LX?

The signal word is no signal word.

What is the physical form of ZIC VEGA DS LX?

ZIC VEGA DS LX is a liquid appearing as liquid, colorless and transparent with colorless and transparent color. It has mild mineral oil odor odor.

What is the solubility of ZIC VEGA DS LX?

Practically insoluble

What is ZIC VEGA DS LX used for?

Hydraulic fluid

What is the melting point of ZIC VEGA DS LX?

The melting point is Not available and the boiling point is 300 °C ~ 580 °C.