NextSDS Logo
Safety Data Sheet EN

SUNOCO VP 68

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SUNOCO VP 68
Product Code
9373

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Specialized Usage Lube Oil

Uses advised against

Not Intended for any other usage

Manufacturers & Suppliers

S

SUNOCO LUBRICANTS

manufacturer

Philadelphia, PA 19154, United States

800-660-0761

Emergency Contacts

CHEMTREC

+1(800) 424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

P201 Obtain Special Instructions Before Use.
P202 Do Not Handle Until All Safety Precautions Are Understood.
P281 Use Personal Protective Equipment As Required.
P308 If Exposed Or Concerned: Get Medical Advice/attention.
P405 Store Locked Up.
P501 Dispose Of Container According To Regional Regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Products containing mineral oil with less than 3% DMSO extract as measured by IP-346.

Chemical Name CAS Number Concentration Hazardous
RESIDUAL OILS, PETROLEUM, SOLVENT-DEWAXED 64742-62-7 8% No
BASE OIL SEVERELY REFINED 64742-65-0 92% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. Maintain an open airway.

Eye contact

Immediately flush eyes with plenty of water occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for atleast 20 minutes.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

Get Medical Attention. Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically. No Specific Treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Material should be handled in enclosed vessels and equipment, in which case general room ventilation should be sufficient. Local exhaust ventilation should be used at points where dust, mist, vapors or gases can escape into the room air. No special requirements under ordinary conditions of use and with adequate ventilation.

Hands

Butyl rubber. Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water.

Eyes

If contact is likely, safety glasses with side shields are recommended.

Respiratory

Use a properly fitted air purifying or supplied air respirator complying with an approved standard if a risk assessment indicates this a necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Skin/Body

Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. Use caution when opening manway covers of storage and transportation containers. 3-nitroaniline crystals may be present on the interior surface of these openings. 3-nitroaniline is toxic by dermal exposure.

Environmental

General room ventilation should be satisfactory. Local exhaust ventilation may be necessary if misting is generated.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
B&C
Colour Intensity
---
Form
---
Odor
Characteristic of Petroleum
Odor Threshold
No Data Available
Ph
No Data Available
Melting Point
---
Boiling Point
No Data Available
Flash Point
248C
Freezing Point
No Data Available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No Data Available
Vapor Pressure
<1 mm Hg
Vapor Density
- 1
Relative Density
<Field Missing>
Bulk Density
---
Density
---
Flammability
Not Applicable
Upper Explosive Limit
No Data Available
Lower Explosive Limit
No Data Available
Explosive Limits
---
Auto Ignition Temperature
Not Determined
Decomposition Temperature
Not Determined
Solubility
---
Partition Coefficient
No Data Available
Solubility In Water
Negligible, 0-1%
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SUNOCO VP 68?

The signal word is no signal word.

What is the physical form of SUNOCO VP 68?

SUNOCO VP 68 is a liquid with b&c color. It has characteristic of petroleum odor.

What is SUNOCO VP 68 used for?

Specialized Usage Lube Oil