NextSDS Logo
Ne

Neutralyt N4

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Neutralyt N4

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Electrolytic marking technology, for aftertreatment, READY FOR USE
Uses Advised Against
Non-industrial purposes

Overview

Neutralyt N4 is a physical state at 20 c and 101.3 kpa: liquid substance commonly used electrolytic marking technology, for aftertreatment, ready for use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Schilling Marking Systems GmbH company logo - Safety Data Sheet supplier organization

Schilling Marking Systems GmbH

undefined

๐Ÿ“

In Grubencker 1 78532 Tuttlingen

๐ŸŒ

DE

๐Ÿ“ž

+49 (0)7461 9472-0

๐Ÿ“ 

+49 (0)7461 9472-28

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

GI/Nord

๐Ÿ“ž

+49 (0)7731/93462

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Watery tenside solution without dye

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Sodium carbonate
EC: 207-838-8
497-19-8 3% โš ๏ธ Hazardous
Benzenesulfonic acid, C10-13-alkyl derivs., sodium salts
EC: 270-115-0
68411-30-3 1% โš ๏ธ Hazardous

Additional Information

Labelling for contents according to regulation (EC) No 648/2004, annex VII: Contains less than 5% anionic surfactant.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathing is difficult, remove victim to fresh air and keep at rest in a position comfortable for breathing. Seek medical attention if problems persist.

Symptoms:

If breathing is difficult

๐Ÿ–๏ธ Skin Contact

Immediately clean with water and soap followed by thorough rinsing. Take off immediately all contaminated clothing and wash it before reuse. In case of skin reactions, consult a physician.

Symptoms:

Skin contact may lead to skin irritation.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of flowing water for 10 to 15 minutes holding eyelids apart. Remove contact lenses, if present and easy to do. Continue rinsing. In case of eye irritation consult an ophthalmologist.

Symptoms:

eye irritation

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Never give anything by mouth to an unconscious person. Seek medical attention.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
at 20 C and 101.3 kPa: liquid
๐Ÿ‘๏ธ Appearance
Physical state at 20 C and 101.3 kPa: liquid
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
odourless
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
approx. 11.5
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
not combustible
Critical Property
๐Ÿ“Š Freezing Point
No data available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
No data available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
at 20 C: 1.01 g/mL
Critical Property
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
at 20 C: completely miscible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
No data available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide for good ventilation or exhaust system or work with completely self-contained equipment.

๐Ÿงค Hand Protection

Recommendation: Protective gloves according to EN 374. Glove material: Nitrile rubber. Observe glove manufacturer's instructions concerning penetrability and breakthrough time.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles according to EN 166.

๐Ÿ˜ท Respiratory Protection

In case of inadequate ventilation wear respiratory protection. The filter class must be suitable for the maximum contaminant concentration (gas/vapour/aerosol/particulates) that may arise when handling the product. If the concentration is exceeded, self-contained breathing apparatus must be used.

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

not applicable

๐Ÿ“ฆ Proper Shipping Name

Not restricted

โš ๏ธ Transport Hazard Class

not applicable

๐Ÿ“‹ Packing Group

not applicable

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Neutralyt N4?

The signal word for this substance is "no signal word".

What is the physical form of Neutralyt N4?

Neutralyt N4 is a liquid appearing as physical state at 20 c and 101.3 kpa: liquid with colourless color. It has odourless odor.

What is Neutralyt N4 used for?

Electrolytic marking technology, for aftertreatment, READY FOR USE

What is the melting point of Neutralyt N4?

The melting point is No data available and the boiling point is No data available.