Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Congo red Highman Reagent A
- Product Code
- 04-210822.A
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
In vitro medical-diagnostic disposable. Reagent for microscopy.
Manufacturers & Suppliers
BIO-OPTICA MILANO SPA
manufacturer
via San Faustino, 58, 20134 Milano (MI) Italia
0039 02 2127131
Emergency Contacts
Poison centres NHS Direct in England or Wales
0845 46 47
Poison centres NHS 24 in Scotland
08454 24 24 24
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to open air. In the event of breathing difficulties, get medical advice/attention immediately.
Remove contaminated clothing. Wash immediately with plenty of water. If irritation persists, get medical advice/attention. Wash contaminated clothing before using it again.
Remove contact lenses, if present. Wash immediately with plenty of water for at least 15 minutes, opening the eyelids fully. If problem persists, seek medical advice.
Get medical advice/attention. Induce vomiting only if indicated by the doctor. Never give anything by mouth to an unconscious person, unless authorised by a doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
carbon dioxide, foam, chemical powder. For product loss or leakage that has not caught fire, water spray can be used to disperse flammable vapours and protect those trying to stem the leak.
Do not use jets of water. Water is not effective for putting out fires but can be used to cool containers exposed to flames to prevent explosions.
Excess pressure may form in containers exposed to fire at a risk of explosion.
Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health. Always wear full fire prevention gear. Collect extinguishing water to prevent it from draining into the sewer system. Dispose of contaminated water used for extinction and the remains of the fire according to applicable regulations.
Firefighter Protection
Normal fire fighting clothing i.e. fire kit (BS EN 469), gloves (BS EN 659) and boots (HO specification A29 and A30) in combination with self-contained open circuit positive pressure compressed air breathing apparatus (BS EN 137).
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Block the leakage if there is no hazard. Send away individuals who are not suitably equipped.
The product must not penetrate into the sewer system or come into contact with surface water or ground water.
Absorb the remainder with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat, sparks and naked flames; do not smoke or use matches or lighters. Avoid bunching of electrostatic charges. When performing transfer operations involving large containers, connect to an earthing system and wear antistatic footwear. Never use compressed air when handling. Open containers with caution as they may be pressurised. Do not eat, drink or smoke during use.
Store only in the original container. Store the containers sealed, in a well ventilated place, away from direct sunlight. Store in a cool and well ventilated place, keep far away from sources of heat, naked flames and sparks and other sources of ignition.
Do not eat, drink or smoke during use.
Keep away from heat, sparks and naked flames; do not smoke or use matches or lighters. Avoid bunching of electrostatic charges. Connect to an earthing system. Never use compressed air when handling.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Workplace must be well aired through effective local aspiration. The product must be used inside a closed circuit, in a well-ventilated environment and with strong localised aspiration systems in place.
Protect hands with category III work gloves (see standard EN 374). The following should be considered when choosing work glove material: compatibility, degradation, failure time and permeability. The work gloves' resistance to chemical agents should be checked before use, as it can be unpredictable. The gloves' wear time depends on the duration and type of use.
Wear airtight protective goggles (see standard EN 166).
If the threshold value (e.g. TLV-TWA) is exceeded for the substance or one of the substances present in the product, wear a mask with a type AX filter, whose limit of use will be defined by the manufacturer (see standard EN 14387). In the presence of gases or vapours of various kinds and/or gases or vapours containing particulate (aerosol sprays, fumes, mists, etc.) combined filters are required. Respiratory protection devices must be used if the technical measures adopted are not suitable for restricting the worker's exposure to the threshold values considered. The protection provided by masks is in any case limited. If the substance considered is odourless or its olfactory threshold is higher than the corresponding TLV-TWA and in the case of an emergency, wear open-circuit compressed air breathing apparatus (in compliance with standard EN 137) or external air-intake breathing apparatus (in compliance with standard EN 138). For a correct choice of respiratory protection device, see standard EN 529.
Wear category I professional long-sleeved overalls and safety footwear (see Regulation 2016/425 and standard EN ISO 20344). Consider the appropriateness of providing antistatic clothing in the case of working environments in which there is a risk of explosion.
The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with environmental standards.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable in normal conditions of use and storage.
There are no particular risks of reaction with other substances in normal conditions of use.
The vapours may also form explosive mixtures with the air. Risk of explosion on contact with: alkaline metals, alkaline oxides, calcium hypochlorite, sulphur monofluoride, acetic anhydride, acids, concentrated hydrogen peroxide, perchlorates, perchloric acid, perchloronitrile, mercury nitrate, nitric acid, silver, silver nitrate, ammonia, silver oxide, ammonia, strong oxidising agents, nitrogen dioxide. May react dangerously with: bromoacetylene, chlorine acetylene, bromine trifluoride, chromium trioxide, chromyl chloride, fluorine, potassium tert-butoxide, lithium hydride, phosphorus trioxide, black platinum, zirconium (IV) chloride, zirconium (IV) iodide.
Avoid overheating. Avoid bunching of electrostatic charges. Avoid all sources of ignition. ETHANOL: Avoid exposure to: sources of heat, naked flames.
alkaline metals, alkaline oxides, calcium hypochlorite, sulphur monofluoride, acetic anhydride, acids, concentrated hydrogen peroxide, perchlorates, perchloric acid, perchloronitrile, mercury nitrate, nitric acid, silver, silver nitrate, ammonia, silver oxide, ammonia, strong oxidising agents, nitrogen dioxide, bromoacetylene, chlorine acetylene, bromine trifluoride, chromium trioxide, chromyl chloride, fluorine, potassium tert-butoxide, lithium hydride, phosphorus trioxide, black platinum, zirconium (IV) chloride, zirconium (IV) iodide.
In the event of thermal decomposition or fire, gases and vapours that are potentially dangerous to health may be released.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
Information not available
12.2. Persistence and degradability
Both Ethanol and Propan-2-ol are identified as rapidly degradable.
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
The product does not contain any PBT or vPvB substances in concentrations ≥ 0.1%.
12.6. Endocrine disrupting properties
The product does not contain substances listed in the main European lists of potential or suspected endocrine disruptors with environmental effects under evaluation.
12.7. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal must be performed through an authorised waste management firm, in compliance with national and local regulations.
Reuse, when possible.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1987
- Shipping Name
- ALCOHOLS, N.O.S. (ETHANOL; PROPAN-2-OL)
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Workers exposed to this health-dangerous chemical agent must undergo sanitary checks carried out in compliance with 2004/37/EC directive.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Congo red Highman Reagent A?
The signal word is danger.
What is the solubility of Congo red Highman Reagent A?
soluble
What is Congo red Highman Reagent A used for?
In vitro medical-diagnostic disposable. Reagent for microscopy.
What are the hazard statements for Congo red Highman Reagent A?
This substance has 2 hazard statements:
- H225: Highly flammable liquid and vapour.
- H350: May cause cancer.