NextSDS Logo
Safety Data Sheet EN

DEVCON® Plastic Steel® Putty (A) Resin

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DEVCON® Plastic Steel® Putty (A) Resin
Product Code
0100
Synonyms
None.

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Not available.

Uses advised against

None known.

Manufacturers & Suppliers

I

ITW Performance Polymers

manufacturer

Bay 150, Shannon Industrial Estate, Co. Clare, Ireland, V14 DF82

353(61)771500

Emergency Contacts

Emergency Contact

44(0) 1235 239 670

24 hours

General in EU

112

Available 24 hours a day.

Austria National Poisons Information Center

+431 406 4343

Available 24 hours a day.

Belgium National Poisons Control Center

070 245 245

Available 24 hours a day.

Bulgaria National Toxicological Information Center

+359 2 9154 233

Available 24 hours a day.

Croatia Poisons Information Center

+385 1 2348 342

Cyprus Poison Center

1401

Available 24 hours a day.

Czech Republic National Poisons Information Center

+420 224 919 293

Czech Republic National Poisons Information Center

+420 224 915 402

Denmark National Poisons Control Center

+45 82 12 12 12

Available 24 hours a day.

Estonia National Poisons Information Center

16662

Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays).

Estonia National Poisons Information Center

(+372) 626 9390

Monday 9:00AM to Saturday 9:00AM (closed on Sundays and on national holidays).

Finland National Poison Information Center

(09) 471 977

Available 24 hours a day.

Finland National Poison Information Center

(09) 4711

Available 24 hours a day.

France National Poisons Control Center

+33 (0) 1 45 42 59 59

Available 24 hours a day.

Greece Poison Information Centre

(0030) 2107793777

Available 24 hours a day.

Hungary National Emergency Phone Number

+36-80-201-199

Available 24 hours a day.

Iceland Poison Center

(+354) 543 2222

Available 24 hours a day.

Latvia Emergency medical aid

113

Latvia Poison and Drug Information Center

+371 67042473

Available 24 hours a day.

Lithuania Neatidéliotina informacija apsinuodijus

+370 5 236 20 52

Lithuania Neatidéliotina informacija apsinuodijus

+37068753378

Malta Accident and Emergency Department

2545 4030

Netherlands National Poisons Information Center (NVIC)

+31 (0)88 755 8000

Norway Norwegian Poison Information Center

22 59 13 00

Available 24 hours a day.

Portugal Poison Center

800 250 250

Available 24 hours a day.

Romania Biroul RSI si Informare Toxicologica

021.318.36.06

Available 8:00AM-3:00PM.

Slovakia National Toxicological Information Center

+421 2 5477 4166

Available 24 hours a day.

Spain Toxicology Information Service

+ 34 91 562 04 20

Available 24 hours a day.

Sweden National Poison Information Center

112

Available 24 hours a day.

Switzerland Tox Info Suisse

145

Available 24 hours a day.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Skin Sens. Cat. 1 H317

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapors/spray.
P264 Wash thoroughly after handling.
P272 Contaminated work clothing should not be allowed out of the workplace.
P280 Wear eye protection/face protection.
P280 Wear protective gloves.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention.
P337 + P313 If eye irritation persists: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Ferrosilicon, [with >= 30% But <= 70% Silicon] 8049-17-0 70 - 80% No
Epoxy Resin: reaction product of bisphenol A and epichlorohydrin (refer to epichlorohydrin) 25068-38-6 10 - 30% Yes
Other components below reportable levels --- 3 - 5% No

Notes

The full text for all H-statements is displayed in section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Call a physician if symptoms develop or persist.

Skin contact

Remove contaminated clothing immediately and wash skin with soap and water. In case of eczema or other skin disorders: Seek medical attention and take along these instructions. Wash contaminated clothing before reuse.

Symptoms: Skin irritation. May cause redness and pain. May cause an allergic skin reaction. Dermatitis. Rash.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention if irritation develops and persists.

Symptoms: Severe eye irritation. Symptoms may include stinging, tearing, redness, swelling, and blurred vision.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Immediate Medical Attention

Provide general supportive measures and treat symptomatically. Keep victim under observation.

Medical Treatment

Provide general supportive measures and treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2).

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

During fire, gases hazardous to health may be formed.

Instructions

Move containers from fire area if you can do so without risk. Use standard firefighting procedures and consider the hazards of other involved materials.

Firefighter Protection

Self-contained breathing apparatus and full protective clothing must be worn in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Keep unnecessary personnel away. Ensure adequate ventilation. Local authorities should be advised if significant spillages cannot be contained.

Small spill

Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.

Large spill

Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water.

Environmental

Avoid discharge into drains, water courses or onto the ground.

Cleanup methods

Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water. Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.

Materials: vermiculite, dry sand, earth, absorbent material (e.g. cloth, fleece)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid breathing dust/fume/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Provide adequate ventilation. Wear appropriate personal protective equipment.

Storage

Store in tightly closed container. Store away from incompatible materials (see Section 10 of the SDS).

Hygiene

Observe good industrial hygiene practices.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Wear appropriate chemical resistant gloves.

Eyes

Wear safety glasses with side shields (or goggles). Face shield is recommended.

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Wear appropriate chemical resistant clothing. Use of an impervious apron is recommended.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour
Dark grey
State Under Standard Conditions
---
Solubility
---
Evaporation Rate
---
Voc Content
---
Crystallisation Point
---
Odor
Slight.
Vapor Pressure
---
Boiling Point
608 °F (320 °C) estimated
Relative Evaporation Rate
---
Vapor Density
---
Solubility In Fat
---
Form
Paste.
Properties Status
---
Flash Point
>399,2 °F (>204,0 °C) Pensky-Martens Closed Cup
Melting Point
---
Colour Intensity
---
Physical State Data
liquid
Lower Explosive Limit
---
Partition Coefficient
---
Solubility In Water
---
Explosive Limits
---
Flammability
---
Odor Threshold
---
Density
2,80 g/cm3
Appearance
---
Molecular Weight
---
Physical State
Not available.
Dynamic Viscosity
---
Softening Point
---
Decomposition Temperature
---
Bulk Density
---
Upper Explosive Limit
---
Cloud Point
---
Metal Corrosion
---
Ph
---
Freezing Point
---
Solidification Point
---
Kinematic Viscosity
---
Auto Ignition Temperature
---
Relative Density
2,8
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

The product is stable and non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Contact with incompatible materials.

Incompatible

Strong oxidizing agents.

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Collect and reclaim or dispose in sealed containers at licensed waste disposal site.

Disposal

Dispose of in accordance with local regulations. This material and its container must be disposed of in a safe manner.

Waste Codes

To be assigned in discussion between the user, the producer and the waste disposal company. The Waste code should be assigned in discussion between the user, the producer and the waste disposal company. EU waste code
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product is classified and labelled in accordance with Regulation (EC) 1272/2008 (CLP Regulation) as amended. This Safety Data Sheet complies with the requirements of Regulation (EC) No 1907/2006, as amended.

Chemical Safety Assessment Not performed

UFI: H710-X0G2-U00P-2J8K

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is DEVCON® Plastic Steel® Putty (A) Resin known by?

DEVCON® Plastic Steel® Putty (A) Resin is also known as: None.

What is the hazard signal word for DEVCON® Plastic Steel® Putty (A) Resin?

The signal word is warning.

What is the physical form of DEVCON® Plastic Steel® Putty (A) Resin?

DEVCON® Plastic Steel® Putty (A) Resin is a not available. with dark grey color. It has slight. odor.

What is DEVCON® Plastic Steel® Putty (A) Resin used for?

Not available.

What are the hazard statements for DEVCON® Plastic Steel® Putty (A) Resin?

This substance has 3 hazard statements:

  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.