NextSDS Logo
TY

TYFO COR [] L

NO SIGNAL WORD Liquide. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
TYFO COR [] L
Product Code
2400

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Liquide antigel et anti-corrosion pour les instalations thermotechniques

Overview

TYFO COR [] L commonly used liquide antigel et anti-corrosion pour les instalations thermotechniques.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

TYFO ROP Chemie GmbH

global supplier

📍

Ausschlger Billdeich 77, D-20539 Hamburg

🌍

DE

📞

+49 (0)40 20 94 97 0

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Centre antipoison - ORFILA

📞

+ 33 (0)1 4542 5959

🌍

FR

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Propane-1,2-diol (propylène glycol). Inhibiteurs.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Propane-1,2-diol
EC: 200-338-0
57-55-6 90-100% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Amener la personne concerne l'air frais. Consulter un mdecin en cas d'apparition de troubles ou de doute.

🖐️ Skin Contact

Aprs contact avec la peau, se laver immdiatement et abondamment avec eau et savon. Consulter un mdecin en cas d'apparition de troubles ou de doute.

👁️ Eye Contact

Rincer aussitt fond l'eau courante pendant au moins 15 minutes en maintenant les paupires cartes. Le cas chant, consulter un ophtalmologiste.

🍽️ Ingestion/Swallowing

NE PAS faire vomir. Rincer la bouche abondamment l'eau. En cas d'ingestion, consulter immdiatement un mdecin et lui montrer l'emballage ou l'tiquette.

🚨 Immediate Medical Attention Required

En cas d'ingestion, consulter immdiatement un mdecin et lui montrer l'emballage ou l'tiquette.

Medical Treatment

Traitement symptmatique.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Liquide.
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Not available
🎨 Colour
Incolore.
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
Presque inodore.
📊 Odor Threshold
non dtermin
🧪 Ph
8.0 - 9.0 (20 C)
🧊 Melting Point
non dtermin
Critical Property
💨 Boiling Point
>150 C ASTM D1120
Critical Property
🔥 Flash Point
>100 C DIN EN 22719 ISO 2719
Critical Property
📊 Freezing Point
<-50 C
📊 Softening Point
Not available
📊 Solidification Point
<-50 C
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Not available
💨 Vapor Pressure
env. 0.2 hPa (20 C)
📊 Vapor Density
Not available
📊 Relative Density
env. 1.055 g/cm [3] (20 C)
📊 Bulk Density
Not available
⚖️ Density
env. 1.055 g/cm [3] (20 C)
Critical Property
🔥 Flammability
non dtermin
📊 Upper Explosive Limit
12.6 % vol. N CAS 57-55-6 propane-1,2-diol
📊 Lower Explosive Limit
2.6 % vol. N CAS 57-55-6 propane-1,2-diol
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
non dtermin
📊 Decomposition Temperature
non dtermin
💧 Solubility
soluble
📊 Partition Coefficient
-1.07 (20.5 C) N CAS 57-55-6 propane-1,2-diol
📊 Solubility In Water
soluble
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
env. 70 mm [2] /s (20 C)
📊 Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Aération et évacuation d'air suffisantes.

🧤 Hand Protection

Indications se référant au matériel des gants de protection [exécution/type, épaisseur, résistance à la pénétration/durée de vie, résistance au mouillage]: Caoutchouc butyle, 0.7 mm, >30 mn, indice de protection 2. Caoutchouc nitrile, 0.4 mm, >30 mn, indice de protection 2. Les gants de protection utilisés doivent satisfaire aux exigences de la directive européenne 89/686/CEE et la norme EN 374 qui en est déduite. Le choix d'un gant de protection adapté à l'utilisation réelle dépend non seulement du matériau, mais aussi d'autres propriétés de qualité souvent différentes d'un fabricant à l'autre. Renseignez-vous chez le fabricant sur le temps de perméation exact du matériel des gants et respectez les indications données.

👁️ Eye Protection

Lunettes de protection étanches (EN 166).

😷 Respiratory Protection

Protection respiratoire en cas de ventilation insuffisante ou d'exposition prolongée. Protection respiratoire en cas de formation d'aérosol ou de brouillard. Protection respiratoire recommandée: Type de filtre: Type de particules (P).

🦺 Skin/Body Protection

Les moyens de protection corporelle doivent être choisis en fonction de l'activité et du temps d'exposition prévu.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for TYFO COR [] L?

The signal word for this substance is "no signal word".

What is the physical form of TYFO COR [] L?

TYFO COR [] L is a liquide. with incolore. color. It has presque inodore. odor.

What is the solubility of TYFO COR [] L?

soluble

What is TYFO COR [] L used for?

Liquide antigel et anti-corrosion pour les instalations thermotechniques

What is the melting point of TYFO COR [] L?

The melting point is non dtermin and the boiling point is >150 C ASTM D1120.