NextSDS Logo
Pr

Propane, R290

DANGER Gaz liqufi sous pression SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Propane, R290

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Rfrigrant, Propulseur pour arosol, Fluides de transfert de chaleur

Overview

Propane, R290 commonly used rfrigrant, propulseur pour arosol, fluides de transfert de chaleur.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (DANGER)

Hazard Classifications

Flam. Gas Category 1 H220
Press. Gas H280

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H220: Gaz extrmement inflammable
  • H280: Contient un gaz sous pression, peut exploser sous leffet de la chaleur

Precautionary Statements

  • P210: Tenir lcart de la chaleur, des surfaces chaudes, des tincelles, des flammes nues et de toute autre source dinflammation. Ne pas fumer.
  • P377: Fuite de gaz enflamm : ne pas teindre si la fuite ne peut pas tre arrte sans danger.
  • P381: Eliminer toutes les sources dignition si cela est faisable sans danger.
  • P403: Stocker dans un endroit bien ventil

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

CALORIE FLUOR company logo - Safety Data Sheet supplier organization

CALORIE FLUOR

national supplier

๐Ÿ“

411 rue Clment Ader FR 78530 BUC

๐ŸŒ

FR

๐Ÿ“ž

+33 /1 39 24 16 70

๐Ÿ“ 

+33 /1 39 56 07 18

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ORFILA

๐Ÿ“ž

+33 1 45 42 59 59

๐ŸŒ

FR

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Propane
EC: 200-827-9
74-98-6 Not specified โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Transporter la personne accidentรฉe ร  l'air frais et la faire tendre. Appeler aussitรดt un mรฉdecin. En cas d'arrรชt respiratoire, respiration artificielle ร  l'aide d'un appareil respiratoire. Appeler le mรฉdecin.

๐Ÿ–๏ธ Skin Contact

Les gelures sont ร  traiter comme les brรปlures thermiques : Lavage immรฉdiat, abondant et prolong ร  l'eau tiรจde.

๐Ÿ‘๏ธ Eye Contact

Lavage immรฉdiat, abondant et prolong ร  l'eau. Si l'irritation persiste, consulter un ophtalmologiste.

๐Ÿฝ๏ธ Ingestion/Swallowing

N'est pas considรฉrรฉe comme รฉtant une voie d'exposition potentielle.

๐Ÿšจ Immediate Medical Attention Required

Traitement symptomatique. Surveiller la circulation sanguine.

Medical Treatment

Traitement symptomatique.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Gaz liqufi sous pression
Critical Property
๐Ÿ“Š Physical State Data
gas
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Incolore
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Gaz liqufi sous pression
๐Ÿ‘ƒ Odor
Doucetre
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
-187,7C
Critical Property
๐Ÿ’จ Boiling Point
-42,1C
Critical Property
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
8,3 bar ( 20C) 17,1 bar ( 50C)
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,5 g/cm [3] ( 20C)
Critical Property
๐Ÿ”ฅ Flammability
Gaz inflammable
๐Ÿ“Š Upper Explosive Limit
10,8 % vol
๐Ÿ“Š Lower Explosive Limit
1,7 % vol.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
470C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Soluble dans les solvants organiques
๐Ÿ“Š Partition Coefficient
log Kow = 2,36
๐Ÿ“Š Solubility In Water
62,4 mg/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
44,1 g/mol
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
0,102mPa.s ( 20C), phase liquide
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Assurer une ventilation adquate

๐Ÿงค Hand Protection

Gants anti-chaleur

๐Ÿ‘๏ธ Eye Protection

Lunettes de scurit avec protections latrales

๐Ÿ˜ท Respiratory Protection

Utiliser un appareil de protection respiratoire autonome lors des oprations de sauvetage et d'entretien dans les cuves de stockage mal ares. Les vapeurs sont plus lourdes que l'air et peuvent provoquer la suffocation par rduction de la teneur en oxygne.

๐Ÿฆบ Skin/Body Protection

Porter un tablier en matire impermable. (viter limprgnation de fluide trs froid dans les tissus au contact de la peau).

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1978

๐Ÿ“ฆ Proper Shipping Name

PROPANE

โš ๏ธ Transport Hazard Class

2.1

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Propane, R290?

The signal word for this substance is "danger".

What is the physical form of Propane, R290?

Propane, R290 is a gaz liqufi sous pression with incolore color. It has doucetre odor.

What is the solubility of Propane, R290?

Soluble dans les solvants organiques

What is Propane, R290 used for?

Rfrigrant, Propulseur pour arosol, Fluides de transfert de chaleur

What are the hazard statements for Propane, R290?

This substance has 2 hazard statements: H220: Gaz extrmement inflammable H280: Contient un gaz sous pression, peut exploser sous leffet de la chaleur

What is the melting point of Propane, R290?

The melting point is -187,7C and the boiling point is -42,1C.