LeakLock (CAS: 68937-41-7 ) commonly used rubber anti-lek (dicht-middel).
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS08
GHS09
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H361: Kan mogelijk de vruchtbaarheid of het ongeboren kind schaden.
- H373: Kan schade aan organen (bijnier) veroorzaken bij langdurige of herhaalde blootstelling (na inslikken).
- H410: Zeer giftig voor in het water levende organismen, met langdurige gevolgen.
Precautionary Statements
- P273: Voorkom lozing in het milieu.
- P281: De nodige persoonlijke beschermingsuitrusting gebruiken.
- P301+P330+P331: NA INSLIKKEN: de mond spoelen. GEEN braken opwekken.
- P303+P361+P353: BIJ CONTACT MET DE HUID (of het haar): verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen [of afdouchen].
- P308+P313: NA (mogelijke) blootstelling: een arts raadplegen.
- P405: Achter slot bewaren.
- P501: Inhoud/verpakking afvoeren naar inzamelpunt voor gevaarlijk of bijzonder afval brengen.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
I.P.M. Solutions
manufacturer
Winnemolenlaan 29, 7339 CE Ugchelen, Nederland
NL
+31654706080
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Nationaal Vergiftigingen Informatie Centrum (UMC Utrecht) Uitsluitend bestemd om professionele hulpverleners te infor- meren bij acute vergiftigingen
+31 30 274 88 88
NL
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Phenol, isopropylated, phosphate (3:1) [Triphenyl phosphate > 5%] EC: 273-066-3 | 68937-41-7 | Not specified | β Non-hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
π« Inhalation Exposure
Voor verse lucht zorgen. Bij onregelmatige ademhaling of ademstilstand direct een arts raadplegen en eerste hulp toedienen. Bij twijfel of bij aanhoudende symptomen een arts raadplegen.
Symptoms:
Bij onregelmatige ademhaling of ademstilstand.
ποΈ Skin Contact
Met veel water en zeep wassen. Bij twijfel of bij aanhoudende symptomen een arts raadplegen.
Symptoms:
Geen specifieke symptomen vermeld.
ποΈ Eye Contact
Contactlenzen verwijderen, indien mogelijk. Blijven spoelen. Minstens 15 minuten met schoon, vloeiend water spoelen terwijl de oogleden worden opengehouden. Een arts raadplegen.
Symptoms:
Geen specifieke symptomen vermeld.
π½οΈ Ingestion/Swallowing
Mond met water spoelen (alleen als de persoon bij bewustzijn is). Veel water in kleine slokken laten drinken (verdunningseffect). GEEN braken opwekken. NA INSLIKKEN: onmiddellijk een arts raadplegen.
Symptoms:
Geen specifieke symptomen vermeld.
π¨ Immediate Medical Attention Required
Voor specialistisch advies dient de arts contact op te nemen met het antigifcentrum.
Medical Treatment
Geen specifieke medische behandelingen vermeld.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
π Engineering Controls
Algemene ventilatie.
π§€ Hand Protection
Draag geschikte handschoenen. Voor gebruik lekdichtheid/ondoordringbaarheid bepalen. Er wordt aangeraden om in geval van speciale applicaties de chemische bestendigheid van de boven genoemde veiligheidshandschoenen samen met de leverancier van de handschoenen na te gaan. Geschikt zijn volgens EN 374 beproefde handschoenen tegen chemicaliΓ«n. Soort materiaal: IIR: isobuteen-isopreen (butyl) rubber. Doorbraaktijd van het handschoenmateriaal >480 minuten (permeatieniveau: 6).
ποΈ Eye Protection
Veiligheidsbril met zijbescherming dragen (EN 166).
π· Respiratory Protection
Bij ontoereikende ventilatie een geschikte adembescherming dragen.
π¦Ί Skin/Body Protection
Beschermende kleding (EN 340 & EN ISO 13688).
π Environmental Exposure Controls
Neem passende maatregelen om verspreiding in het milieu te voorkomen. Vermijden dat het product in afvoerkanalen, oppervlaktewater of grondwater terechtkomt.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
π·οΈ UN Number
3082
π¦ Proper Shipping Name
MILIEUGEVAARLIJKE VLOEISTOF, N.E.G.
β οΈ Transport Hazard Class
9 (milieugevaarlijk)
π Packing Group
III (minder gevaarlijke stof)
π ADR Transport Precautions
Aan de bepalingen voor gevaarlijke goederen (ADR) moet ook in het bedrijf worden voldaan.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for LeakLock?
The signal word for this substance is "warning".
What is the physical form of LeakLock?
LeakLock is a vloeibaar with kleurloos color. It has geurloos odor.
What is LeakLock used for?
Rubber anti-lek (dicht-middel)
What are the hazard statements for LeakLock?
This substance has 3 hazard statements: H361: Kan mogelijk de vruchtbaarheid of het ongeboren kind schaden. H373: Kan schade aan organen (bijnier) veroorzaken bij langdurige of herhaalde blootstelling (na inslikken). H410: Zeer giftig voor in het water levende organismen, met langdurige gevolgen.
What is the melting point of LeakLock?
The melting point is <- 20 β and the boiling point is >400 Β°C bij 98 kPa.