NextSDS Logo
Co

Corridor Wipe

NO SIGNAL WORD Vloeibaar SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Corridor Wipe

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
NHT0-G0TG-P008-945J

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
EuPCS: PC-CLN-2 Niet-schurende reinigers voor algemeen (of multifunctioneel) gebruik, PC-CLN-13.2 Vloerverzorgingsmiddelen, bijvoorbeeld wassen, emulsies Procescategorien [PROC]: 8, 10

Overview

Corridor Wipe commonly used eupcs: pc-cln-2 niet-schurende reinigers voor algemeen (of multifunctioneel) gebruik, pc-cln-13.2 vloerverzorgingsmiddelen, bijvoorbeeld wassen, emulsies procescategorien [proc]: 8, 10.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BUZIL-WERK Wagner GmbH & Co. KG company logo - Safety Data Sheet supplier organization

BUZIL-WERK Wagner GmbH & Co. KG

manufacturer

๐Ÿ“

Fraunhofer Str. 17 D-87700 Memmingen

๐ŸŒ

DE

๐Ÿ“ 

+49 (0) 8331 930-880

๐ŸŒ www.buzil.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 (0) 8331 930-6

๐ŸŒ

DE

๐Ÿ•’

08:00 - 16:00 h

Emergency Contact

๐Ÿ“ž

070 245 245

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

< 5 % niet-ionogene oppervlakteactieve stoffen, parfums, conserveringsmiddelen (Phenoxyethanol, Benzisothiazolinone, Sodium pyrithione).

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
1-Ethoxy-2-propanol
EC: 216-374-5
1569-02-4 1-5% โš ๏ธ Hazardous
Ethanol
EC: 200-578-6
64-17-5 1-5% โš ๏ธ Hazardous
Decan-1-ol, ethoxylated 26183-52-8 1-5% โš ๏ธ Hazardous

Composition Notes

Volledige inhoud van de H- en EUH-zinnen: zie rubriek 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Voor frisse lucht zorgen.

๐Ÿ–๏ธ Skin Contact

Verontreinigde kleding uittrekken en wassen alvorens deze opnieuw te gebruiken.

๐Ÿ‘๏ธ Eye Contact

Direct voorzichtig en grondig met oogdouche of met water spoelen.

๐Ÿฝ๏ธ Ingestion/Swallowing

Onmiddellijk mond spoelen en veel water drinken.

Medical Treatment

Symptomatische behandeling.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Vloeibaar
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
groen
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Parfums, geurmiddelen
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
8,2 - 8,8 (bij 20 C)
๐ŸงŠ Melting Point
ca. 0 C
Critical Property
๐Ÿ’จ Boiling Point
ca. 100 C
Critical Property
๐Ÿ”ฅ Flash Point
niet van toepassing
Critical Property
๐Ÿ“Š Freezing Point
ca. 0 C
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
niet bepaald
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
niet bepaald
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,01 g/cm (bij 20 C)
Critical Property
๐Ÿ”ฅ Flammability
niet van toepassing
๐Ÿ“Š Upper Explosive Limit
niet bepaald
๐Ÿ“Š Lower Explosive Limit
niet bepaald
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
niet bepaald
๐Ÿ“Š Decomposition Temperature
niet van toepassing
๐Ÿ’ง Solubility
niet bepaald
๐Ÿ“Š Partition Coefficient
niet van toepassing
๐Ÿ“Š Solubility In Water
volledig mengbaar (bij 20 C)
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
< 10 mPas 50 1/s (bij 25 C)
๐Ÿ“Š Kinematic Viscosity
niet bepaald (bij 40 C)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Gebruik van beschermende handschoenen: Een lijst met geschikte producten en gedetailleerde vermeldingen van de draagduur is op aanvraag te verkrijgen. Het gebruik van veiligheidshandschoenen is niet nodig indien gelijkwaardige veiligheidsmaatregelen met inachtneming van een verhoogde huidbelasting door vochtig werk worden getroffen (bijv. gebruik van geschikte huidbeschermingszalf).

๐Ÿ‘๏ธ Eye Protection

Oogbescherming: niet vereist.

๐Ÿ˜ท Respiratory Protection

Normaal gesproken is geen persoonlijke adembescherming noodzakelijk.

๐Ÿฆบ Skin/Body Protection

Draag geschikte werkkleding.

๐ŸŒ Environmental Exposure Controls

Rubriek 6: Maatregelen bij het accidenteel vrijkomen van de stof of het mengsel

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Corridor Wipe?

The signal word for this substance is "no signal word".

What is the physical form of Corridor Wipe?

Corridor Wipe is a vloeibaar with groen color. It has parfums, geurmiddelen odor.

What is the solubility of Corridor Wipe?

niet bepaald

What is Corridor Wipe used for?

EuPCS: PC-CLN-2 Niet-schurende reinigers voor algemeen (of multifunctioneel) gebruik, PC-CLN-13.2 Vloerverzorgingsmiddelen, bijvoorbeeld wassen, emulsies Procescategorien [PROC]: 8, 10

What is the melting point of Corridor Wipe?

The melting point is ca. 0 C and the boiling point is ca. 100 C.