NextSDS Logo
QP

QP. LUCITANTO

emulsion SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
QP. LUCITANTO

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
High quality water-based decorative pearl paint, it is used to create a random velvet effect on walls. It is available in different colors and it is applicable on interior surfaces only.

Overview

QP. LUCITANTO commonly used high quality water-based decorative pearl paint, it is used to create a random velvet effect on walls. it is available in different colors and it is applicable on interior surfaces only..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

N/A

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Quds Paints

manufacturer

๐Ÿ“

Industrial Zone, Sahab _Jordan 11512

๐ŸŒ

JO

๐Ÿ“ž

+962 (6) 4029023

๐Ÿ“ 

+962 (6) 4020504

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Copolymer of: Vinyl acetate ethylene.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move the exposed person to fresh air at once. Get medical attention if any discomfort continues.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of water or water and soap. Get medical attention if irritation persists after washing.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water. Seek medical advice in case of continuous irritation.

๐Ÿฝ๏ธ Ingestion/Swallowing

If conscious, give several small portions of water to drink. Do not induce vomiting. In cases of sickness seek medical advice.

๐Ÿšจ Immediate Medical Attention Required

Medical assistance should be sought. Depending on the symptoms, invasive measures may be necessary.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Water spray, water mist, extinguishing powder, foam, carbon dioxide.

โŒ Unsuitable Extinguishing Media

Water jet.

โš ๏ธ Specific Fire Hazards

Hazardous combustion products: hydrogen chloride.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Use respiratory protection independent of re circulated air.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐Ÿšจ Emergency Procedures

Avoid dust formation. Do not breathe dust.

๐ŸŒ Environmental Precautions

Cover any spilled material in accordance with regulations to prevent dispersal by wind.

๐Ÿงน Cleanup Methods

Disposed of according to local/state/federal regulations.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
emulsion
Critical Property
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Multicolor
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
odorless
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
7-9
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
soluble
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Prevent air-borne concentrations higher than the occupational exposure limits.

โ€ข Keep the container tightly closed.

โ€ข Exclude sources of heat, sparks and open flame.

โ€ข Avoid skin and eye contact.

โ€ข Avoid inhalation of vapor.

โ€ข Smoking, eating and drinking should be prohibited in storage and use areas.

โ€ข Always keep in containers made of the same material as the supply container, or in containers that are compatible with the product.

๐Ÿช Storage Conditions

โ€ข Store in a cool, dry, well ventilated place away from sources of heat, ignition and direct sunlight.

โ€ข Prevent unauthorized access.

โ€ข Containers which are opened should be properly resealed and kept upright to prevent leakage.

๐Ÿงผ General Hygiene Measures

Smoking, eating and drinking should be prohibited in storage and use areas.

๐Ÿ”ฅ Fire Prevention Measures

Exclude sources of heat, sparks and open flame.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide adequate ventilation. Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction.

๐Ÿงค Hand Protection

Wear suitable gloves for protection against materials.

๐Ÿ‘๏ธ Eye Protection

Eye protection designed to protect against liquid splashes should be worn.

๐Ÿ˜ท Respiratory Protection

If ventilation is not sufficient to maintain concentrations of particulates and solvent vapor below the occupational exposure limit, respiratory protection must be worn.

๐ŸŒ Environmental Exposure Controls

Prevent material from entering surface waters and soil.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

If stored and handled in accordance with standard industrial practices no hazardous reactions are known.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Toxicity

Assessment: No expected damaging effects to aquatic organisms. According to current knowledge adverse effects on water purification plants are not expected.

๐ŸŒฑ Persistence and degradability

Assessment: Polymer component: Elimination by adsorption to activated sludge. Separation by flocculation is possible. Polymer components: Not readily biodegradable.

๐ŸŒฑ Bioaccumulative potential

Assessment: No adverse effects expected.

๐ŸŒฑ Mobility in soil

Assessment: No adverse effects expected.

๐ŸŒฑ Other adverse effects

None known.

๐ŸŒฑ Additional information

The ecotoxicological results provided were obtained from tests with similar products.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

โ™ป๏ธ Waste Treatment Methods

Dispose of according to regulations by incineration in a special waste incinerator. Small quantities may be disposed of by incineration in an approved facility. Observe local/state/federal regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

๐Ÿ“‹ Regulatory Summary

National and local regulations must be observed.

โŒ Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the physical form of QP. LUCITANTO?

QP. LUCITANTO is a emulsion with multicolor color. It has odorless odor.

What is the solubility of QP. LUCITANTO?

soluble

What is QP. LUCITANTO used for?

High quality water-based decorative pearl paint, it is used to create a random velvet effect on walls. It is available in different colors and it is applicable on interior surfaces only.