NextSDS Logo
LA

LAGD 60/125 (Battery)

NO SIGNAL WORD Battery SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
LAGD 60/125 (Battery)

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Battery

Overview

LAGD 60/125 (Battery) commonly used battery.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

SKF MPT company logo - Safety Data Sheet supplier organization

SKF MPT

undefined

๐Ÿ“

Meidoornkade 14, 3992 AE AE Houten

๐ŸŒ

NL

๐Ÿ“ž

+31 30 6307200

๐ŸŒ www.skf.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

NHS 111 (Scotland: NHS 24)

๐Ÿ“ž

111

๐ŸŒ

GB

๐Ÿ’ก

Members of the public

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
zinc powder - zinc dust
EC: 231-175-3
7440-66-6 18-44% โš ๏ธ Hazardous
manganese dioxide
EC: 215-202-6
1313-13-9 14% โš ๏ธ Hazardous
potassium hydroxide
EC: 215-181-3
1310-58-3 2-6% โš ๏ธ Hazardous
Copper
EC: 231-159-6
7440-50-8 2% โœ“ Non-hazardous

Composition Notes

Please see section 16 for the full text of H- / EUH-phrases.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Seek fresh air. Seek medical advice in case of persistent discomfort.

๐Ÿ–๏ธ Skin Contact

Immediately remove contaminated clothing, watch and jewellery. Wash skin with soap and water. Seek medical advice immediately.

๐Ÿ‘๏ธ Eye Contact

Open eye wide, remove any contact lenses and flush immediately with water (preferably using eye wash equipment). Seek medical advice immediately. Continue flushing until medical attention is obtained.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting. If vomiting occurs, keep head low so that stomach contents do not enter lungs. Wash out mouth thoroughly and drink 1-2 glasses of water in small sips. Seek medical advice immediately.

๐Ÿšจ Immediate Medical Attention Required

Seek medical advice immediately. Continue flushing until medical attention is obtained. Ensure that medical personnel are aware of the material involved, and take precautions to protect themselves.

Medical Treatment

Treat symptoms.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Battery
Critical Property
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Intact, closed container: Not required. In the event of direct skin contact, wear protective gloves: Type of material: Butyl rubber. Breakthrough time has not been determined for the product. Change gloves often. Gloves must conform to EN 374.

๐Ÿ‘๏ธ Eye Protection

Intact, closed container: Not required. In case of leaking battery: Wear safety goggles if there is a risk of eye splash. Eye protection must conform to EN 166.

๐Ÿ˜ท Respiratory Protection

Intact, closed container: Not required. In case of risk of formation of spray mist, wear respiratory protective equipment with P2 filter. Respiratory protection must conform to one of the following standards: EN 136/140/145.

๐ŸŒ Environmental Exposure Controls

Ensure compliance with local regulations for emissions.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LAGD 60/125 (Battery)?

The signal word for this substance is "no signal word".

What is the physical form of LAGD 60/125 (Battery)?

LAGD 60/125 (Battery) is a battery .

What is LAGD 60/125 (Battery) used for?

Battery