Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
LUBRIZOL CV1201X commonly used heavy duty diesel.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H412: Harmful to aquatic life with long lasting effects.
Precautionary Statements
- P273: Avoid release to the environment.
- P501: Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
LUBRIZOL FRANCE
undefined
25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173
FR
(33) 02.35.58.14.00
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
CHEMTREC
(+1) 703 527 3887
US
FOR TRANSPORT EMERGENCY CALL
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureChemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
Mineral oil EC: 265-157-1 | N/A | 20-50% | โ ๏ธ Hazardous |
Reaction products of Benzeneamine, N-phenyl- with nonene (branched) EC: 253-249-4 | N/A | 10-25% | โ ๏ธ Hazardous |
Reaction products of benzenesulfonic acid, mono-C20-24 (even)-sec-alkyl derivs. para, calcium salts EC: 947-519-7 | N/A | 1-5% | โ ๏ธ Hazardous |
zinc O,O,O',O'-tetrakis(1,3-dimethylbutyl) bis(phosphorodithioate) EC: 218-679-9 | N/A | 3-5% | โ ๏ธ Hazardous |
Calcium branched alkyl phenate sulphide (overbased) | N/A | 1-5% | โ ๏ธ Hazardous |
Phosphorodithioic acid, mixed O,O-bis(1,3-dimethylbutyl and iso-Pr)esters, zinc salts EC: 283-392-8 | N/A | 1-2.5% | โ ๏ธ Hazardous |
Phenol, dodecyl-, branched EC: 310-154-3 | N/A | 0.01-0.25% | โ ๏ธ Hazardous |
Composition Notes
600, 700 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only. The full text for all H-phrases is displayed in section 16. See Section 15 for Regulation (EC) No. 1907/2006 REACH Article 59(1). Candidate List (Substances of Very High Concern (SVHC))
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Remove exposed person to fresh air if adverse effects are observed.
๐๏ธ Skin Contact
Take off contaminated clothing and wash before re-use. Wash with soap and water. If skin irritation occurs, get medical attention. Launder contaminated clothing before reuse.
๐๏ธ Eye Contact
Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.
๐ฝ๏ธ Ingestion/Swallowing
Rinse mouth. Get medical attention if symptoms occur.
๐จ Immediate Medical Attention Required
No data available.
Medical Treatment
Treat symptomatically.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Material should be handled in enclosed vessels and equipment, in which case general (mechanical) room ventilation should be sufficient. Local exhaust ventilation should be used at points where dust, mist, vapors or gases can escape into the room air.
๐งค Hand Protection
Use nitrile or neoprene gloves. Use good industrial hygiene practices. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks involving thermal hazards, the standards set out in EN 407 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For short-term, transient exposures and splash protection, gloves with shorter breakthrough times may commonly be used. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. Thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. Thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential.
๐๏ธ Eye Protection
If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.
๐ท Respiratory Protection
A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill cleanup sites. Use respirator with an organic vapor and dust/mist cartridge if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions. Please refer to the relevant EN standards for the RPE selected.
๐ฆบ Skin/Body Protection
Chemical resistant boots.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for LUBRIZOL CV1201X?
The signal word for this substance is "no signal word".
What is the physical form of LUBRIZOL CV1201X?
LUBRIZOL CV1201X is a liquid with dark brown color. It has mild odor.
What is the solubility of LUBRIZOL CV1201X?
No data available.
What is LUBRIZOL CV1201X used for?
Heavy Duty Diesel
What are the hazard statements for LUBRIZOL CV1201X?
This substance has 1 hazard statements: H412: Harmful to aquatic life with long lasting effects.