NextSDS Logo
LU

LUBRIZOL CV1201X

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
LUBRIZOL CV1201X

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Heavy Duty Diesel
Uses Advised Against
None identified.

Overview

LUBRIZOL CV1201X commonly used heavy duty diesel.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Not applicable)

Hazard Classifications

Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P501: Dispose of contents/container to an appropriate treatment and disposal facility in accordance with applicable laws and regulations, and product characteristics at time of disposal.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

LUBRIZOL FRANCE company logo - Safety Data Sheet supplier organization

LUBRIZOL FRANCE

undefined

๐Ÿ“

25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173

๐ŸŒ

FR

๐Ÿ“ž

(33) 02.35.58.14.00

๐ŸŒ www.mylubrizol.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

(+1) 703 527 3887

๐ŸŒ

US

๐Ÿ’ก

FOR TRANSPORT EMERGENCY CALL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Mineral oil
EC: 265-157-1
N/A 20-50% โš ๏ธ Hazardous
Reaction products of Benzeneamine, N-phenyl- with nonene (branched)
EC: 253-249-4
N/A 10-25% โš ๏ธ Hazardous
Reaction products of benzenesulfonic acid, mono-C20-24 (even)-sec-alkyl derivs. para, calcium salts
EC: 947-519-7
N/A 1-5% โš ๏ธ Hazardous
zinc O,O,O',O'-tetrakis(1,3-dimethylbutyl) bis(phosphorodithioate)
EC: 218-679-9
N/A 3-5% โš ๏ธ Hazardous
Calcium branched alkyl phenate sulphide (overbased) N/A 1-5% โš ๏ธ Hazardous
Phosphorodithioic acid, mixed O,O-bis(1,3-dimethylbutyl and iso-Pr)esters, zinc salts
EC: 283-392-8
N/A 1-2.5% โš ๏ธ Hazardous
Phenol, dodecyl-, branched
EC: 310-154-3
N/A 0.01-0.25% โš ๏ธ Hazardous

Composition Notes

600, 700 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only. The full text for all H-phrases is displayed in section 16. See Section 15 for Regulation (EC) No. 1907/2006 REACH Article 59(1). Candidate List (Substances of Very High Concern (SVHC))

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove exposed person to fresh air if adverse effects are observed.

๐Ÿ–๏ธ Skin Contact

Take off contaminated clothing and wash before re-use. Wash with soap and water. If skin irritation occurs, get medical attention. Launder contaminated clothing before reuse.

๐Ÿ‘๏ธ Eye Contact

Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Get medical attention if symptoms occur.

๐Ÿšจ Immediate Medical Attention Required

No data available.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Dark brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
Mild
๐Ÿ“Š Odor Threshold
No data available.
๐Ÿงช Ph
No data available.
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
No data available.
Critical Property
๐Ÿ”ฅ Flash Point
171 C (Pensky-Martens Closed Cup)
Critical Property
๐Ÿ“Š Freezing Point
No data available.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available.
๐Ÿ’จ Vapor Pressure
No data available.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
0.919 - 0.959 (15.6 C)
๐Ÿ“Š Bulk Density
7.82 lb/gal (15.6 C)
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
No data available.
๐Ÿ“Š Upper Explosive Limit
No data available.
๐Ÿ“Š Lower Explosive Limit
No data available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available.
๐Ÿ“Š Decomposition Temperature
No data available.
๐Ÿ’ง Solubility
No data available.
๐Ÿ“Š Partition Coefficient
No data available.
๐Ÿ“Š Solubility In Water
Insoluble in water
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
No data available.
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
1352 mm2/s (40 C); 86 mm2/s (100 C )
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Material should be handled in enclosed vessels and equipment, in which case general (mechanical) room ventilation should be sufficient. Local exhaust ventilation should be used at points where dust, mist, vapors or gases can escape into the room air.

๐Ÿงค Hand Protection

Use nitrile or neoprene gloves. Use good industrial hygiene practices. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks involving thermal hazards, the standards set out in EN 407 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For short-term, transient exposures and splash protection, gloves with shorter breakthrough times may commonly be used. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. Thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. Thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential.

๐Ÿ‘๏ธ Eye Protection

If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.

๐Ÿ˜ท Respiratory Protection

A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill cleanup sites. Use respirator with an organic vapor and dust/mist cartridge if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions. Please refer to the relevant EN standards for the RPE selected.

๐Ÿฆบ Skin/Body Protection

Chemical resistant boots.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LUBRIZOL CV1201X?

The signal word for this substance is "no signal word".

What is the physical form of LUBRIZOL CV1201X?

LUBRIZOL CV1201X is a liquid with dark brown color. It has mild odor.

What is the solubility of LUBRIZOL CV1201X?

No data available.

What is LUBRIZOL CV1201X used for?

Heavy Duty Diesel

What are the hazard statements for LUBRIZOL CV1201X?

This substance has 1 hazard statements: H412: Harmful to aquatic life with long lasting effects.