Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LOCTITE 262
- Product Code
- 26221
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Anaerobic Sealant
Uses advised against
None identified
Manufacturers & Suppliers
Henkel Corporation
manufacturer
One Henkel Way, Rocky Hill, Connecticut 06067
+1 (860) 571-5100
http://www.henkelna.com
Emergency Contacts
Poison Control Center
1-877-671-4608
Poison Control Center
1-303-592-1711
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Saccharin | 81-07-2 | 1 - 5% | Yes |
| Ethene, homopolymer | 9002-88-4 | 1 - 5% | Yes |
| Cumene hydroperoxide | 80-15-9 | 1 - 5% | Yes |
| Methyl methacrylate | 80-62-6 | 0.1 - 1% | Yes |
Notes
Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Get medical attention.
Immediately flush skin with plenty of water (using soap, if available). Remove contaminated clothing and footwear. Wash clothing before reuse. Get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
DO NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.
Immediate Medical Attention
Get medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray (fog), foam, dry chemical or carbon dioxide.
Uncontrolled polymerization may occur at high temperatures resulting in explosions or rupture of storage containers.
In case of fire, keep containers cool with water spray.
Firefighter Protection
Wear self-contained breathing apparatus and full protective clothing, such as turn-out gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Isolate the hazard area and deny entry to unnecessary and unprotected personnel. Evacuate and ventilate spill area; dike spill to prevent entry into water system; wear full protective equipment during clean-up. Soak up with inert absorbent material. Scrape up as much material as possible.
Do not allow product to enter sewer or waterways.
Soak up with inert absorbent material; Scrape up as much material as possible.
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only with adequate ventilation. Prevent contact with eyes, skin and clothing. Do not breathe vapor and mist. Wash thoroughly after handling. Keep container closed.
Store between 0 °C (32°F) and 32 °C (89.6 °F). Keep in a cool, well ventilated area away from heat, sparks and open flame. Keep container tightly closed until ready for use.
Wash thoroughly after handling.
Keep in a cool, well ventilated area away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate local exhaust ventilation to maintain worker exposure below exposure limits.
Neoprene gloves.
Safety goggles or safety glasses with side shields. Full face protection should be used if the potential for splashing or spraying of product exists. Safety showers and eye wash stations should be available.
Use NIOSH approved respirator if there is potential to exceed exposure limit(s).
Use chemical resistant, impermeable clothing including gloves and either an apron or body suit to prevent skin contact.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions of storage and use.
Not available.
None under normal processing. Polymerization may occur at elevated temperature or in the presence of incompatible materials.
Elevated temperatures. Heat, flames, sparks and other sources of ignition. Store away from incompatible materials.
Iron. Copper. Rust. Aluminum. Zinc. Reducing agents. Strong acids and oxidizing agents. Oxygen scavengers. Strong alkalis.
Oxides of carbon. Oxides of sulfur. Oxides of nitrogen. Phenolics. Irritating organic vapours.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Follow all local, state, federal and provincial regulations for disposal.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 3082
- Shipping Name
- RQ, Environmentally hazardous substance, liquid, n.o.s.
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LOCTITE 262?
The signal word is warning.
What is the physical form of LOCTITE 262?
LOCTITE 262 is a liquid with red color. It has mild odor.
What is LOCTITE 262 used for?
Anaerobic Sealant
What are the hazard statements for LOCTITE 262?
This substance has 3 hazard statements:
- H315 + H320: CAUSES SKIN AND EYE IRRITATION.
- H317: MAY CAUSE AN ALLERGIC SKIN REACTION.
- H373: MAY CAUSE DAMAGE TO ORGANS THROUGH PROLONGED OR REPEATED EXPOSURE.
What is the melting point of LOCTITE 262?