Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MAYER HEMATOXYLIN Nuclear stain
- Product Code
- C0301-2-3-4-5-6-C030AA
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for Anatomy Pathology
Uses advised against
not any
Manufacturers & Suppliers
DIAPATH SpA
manufacturer
Via Savoldini, 71 - 24057 Martinengo (BG) -ITALY
+(39) 0363/986411
Emergency Contacts
Centro Antiveleni - Ospedale di Niguarda - Milano
+39 02/66101029
Centro Antiveleni - Osp. Maggiore - Unità operativa di Tossicologia - Bologna
+39 051/382984235
Centro Antiveleni - Università di Roma, Policlinico Umberto I
+39 06/490663
Centro Antiveleno - Università di Torino
+39 011/637637
Centro Antiveleni - Ospedali Riuniti Cardarelli (c/o Usl 40) - Napoli
+39 081/5453333
Centro Antiveleni - Unità degli Studi di Messina (c/o Facoltà di Farmacia)
090/6764059
Centro Antiveleni - Istituto per l'Infanzia - Trieste
+39 040/3785373
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Hazardous components within the meaning of the CLP regulation and related classification:
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| chloral hydrate; 2,2,2-trichloroethane-1,1-diol EC: 206-117-5 | 302-17-0 | 3 - 5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove casualty to fresh air and keep warm and at rest.
Wash with plenty of water and soap.
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.
Do not under any circumstances induce vomiting. OBTAIN A MEDICAL EXAMINATION IMMEDIATELY.
Immediate Medical Attention
OBTAIN A MEDICAL EXAMINATION IMMEDIATELY.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water. Carbon dioxide (CO2).
None in particular.
Do not inhale explosion and combustion gases. Burning produces heavy smoke.
Move undamaged containers from immediate hazard area if it can be done safely.
Firefighter Protection
Use suitable breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear personal protection equipment. Remove persons to safety.
Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. Retain contaminated washing water and dispose it.
Wash with plenty of water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes, inhalation of vapours and mists.
Keep away from food, drink and feed.
Do not eat or drink while working.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Not needed for normal use.
Not needed for normal use. Anyway, operate according good working practices.
Not needed for normal use.
No special precaution must be adopted for normal use.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions
Stable under normal conditions
Stable under normal conditions.
None in particular.
None.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Recover if possible. In so doing, comply with the local and national regulations currently in force.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- N.A.
- Transport Class
- N.A.
- Packing Group
- N.A.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Dir. 98/24/EC, Dir. 2000/39/EC, Regulation (EC) n. 1907/2006 (REACH), Regulation (EC) n. 1272/2008 (CLP), Regulation (EC) n. 790/2009 (ATP 1 CLP), (EU) n. 758/2013, Regulation (EU) 2015/830, Regulation (EU) n. 286/2011 (ATP 2 CLP), Regulation (EU) n. 618/2012 (ATP 3 CLP), Regulation (EU) n. 487/2013 (ATP 4 CLP), Regulation (EU) n. 944/2013 (ATP 5 CLP), Regulation (EU) n. 605/2014 (ATP 6 CLP)
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MAYER HEMATOXYLIN Nuclear stain?
The signal word is no signal word.
What is the physical form of MAYER HEMATOXYLIN Nuclear stain?
MAYER HEMATOXYLIN Nuclear stain is a liquid appearing as liquid purple with purple color. It has characteristic odor.
What is MAYER HEMATOXYLIN Nuclear stain used for?
Reagent for Anatomy Pathology