Basic Product Information

Product Name
HistoPot - 10% Buffered Formalin
Product Code
S10-B-FOR-; 10-B-FOR-; (S) 10-B-FOR

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Fixative for Histology

Overview

HistoPot - 10% Buffered Formalin is a form: fluid colour: according to product specification substance commonly used fixative for histology.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Muta. Category 2 H341
Carc. Category 1B H350
Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.
  • H341: Suspected of causing genetic defects.
  • H350: May cause cancer.

Precautionary Statements

  • P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P308+P313: IF exposed or concerned: Get medical advice/attention.
  • P321: Specific treatment (see on this label).
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Serosep Ltd.

manufacturer

๐Ÿ“

Annacotty Business Park Annacotty Co. Limerick Ireland

๐ŸŒ

IE

๐Ÿ“ž

+353 61 358190

๐Ÿ“ 

+353 61 358191

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

National Poisons Information Centre, Beaumont Hospital, Dublin 9.

๐Ÿ“ž

01 8092566

๐ŸŒ

IE

๐Ÿ•’

8am-10pm (seven days)

๐Ÿ’ก

Emergency medical information

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mixture of substances listed below with nonhazardous additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
formaldehyde
EC: 200-001-8
50-00-0 4% โš ๏ธ Hazardous
methanol
EC: 200-659-6
67-56-1 1% โš ๏ธ Hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air and to be sure call for a doctor. In case of unconsciousness place patient stably in side position for transportation.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water.

๐Ÿฝ๏ธ Ingestion/Swallowing

Call for a doctor immediately.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Form: Fluid Colour: According to product specification
๐ŸŽจ Colour
According to product specification
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Fluid
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ’จ Boiling Point
100 C
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable.
Critical Property
๐Ÿ“Š Freezing Point
Undetermined.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
23 hPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not determined.
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Product is not selfigniting.
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Fully miscible.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
5.00 %
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Nitrile chemical gloves should be used when handling formaldehyde solutions. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles. Suitable eye protection, for example, chemical rated safety glasses, goggles or face shield, should be used.

๐Ÿ˜ท Respiratory Protection

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. If egineeriing contols cannot provide adequate protectionthen a certified respirator, fitted with an appropriate chemical vapour cartridge such as an A2B2E2K2P3 rated filter should be used. Users must be trained in the care, use, and replacement of respirators and filters.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for HistoPot - 10% Buffered Formalin?

The signal word for this substance is "danger".

What is the physical form of HistoPot - 10% Buffered Formalin?

HistoPot - 10% Buffered Formalin is a fluid appearing as form: fluid colour: according to product specification with according to product specification color. It has characteristic odor.

What is HistoPot - 10% Buffered Formalin used for?

Fixative for Histology

What are the hazard statements for HistoPot - 10% Buffered Formalin?

This substance has 3 hazard statements: H317: May cause an allergic skin reaction. H341: Suspected of causing genetic defects. H350: May cause cancer.

What is the melting point of HistoPot - 10% Buffered Formalin?

The melting point is Undetermined. and the boiling point is 100 C.