NextSDS Logo
Safety Data Sheet DE

Armaflex-Kleber 520

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Armaflex-Kleber 520

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

A

Armstrong World Industries GmbH

manufacturer

Robert-Bosch-Straße 10, D-48153 Münster, Postfach 11 80, D-48001 Münster

0251-7603-0

Emergency Contacts

Landesberatungsstelle für Vergiftungserscheinungen Berlin

030/3023022

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Flam. Liq.

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Kontaktklebstoff auf Basis Polychloroprene

Chemical Name CAS Number Concentration Hazardous
2-Butanon 78-93-3 2.5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Frischluftzufuhr, bei Beschwerden Arzt aufsuchen.

Skin contact

Mit viel Wasser und Seife waschen

Eye contact

Augen bei geöffnetem Lidspalt mehrere Minuten mit fließendem Wasser spülen.

Ingestion

Bei anhaltenden Beschwerden Arzt konsultieren

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Löschpulver oder Wassersprühstrahl. Größeren Brand mit Wassersprühstrahl oder alkoholbeständigem Schaum bekämpfen.

Unsuitable media

Wasser im Vollstrahl.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Schutzausrüstung tragen. Ungeschützte Personen fernhalten.

Environmental

Nicht in die Kanalisation oder in Gewässer gelangen lassen. Eindringen in Kanalisation, Gruben und Keller verhindern.

Cleanup methods

Mit flüssigkeitsbindendem Material aufnehmen.

Materials: Sand, Kieselgur, Säurebinder, Universalbinder, Sägemehl

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Für gute Belüftung/Absaugung am Arbeitsplatz sorgen.

Storage

An einem kühlen Ort lagern. Behälter dicht geschlossen halten. In gut verschlossenen Gebinden kühl und trocken lagern. Vor Hitze und direkter Sonnenbestrahlung schützen.

Fire prevention

Zündquellen fernhalten - nicht rauchen. Maßnahmen gegen elektrostatische Aufladung treffen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Keine weiteren Angaben, siehe Punkt 7.

Hands

Nicht erforderlich.

Eyes

Dichtschließende Schutzbrille

Respiratory

Bei kurzzeitiger oder geringer Belastung Atemfiltergerät; bei intensiver bzw. längerer Exposition umluftunabhängiges Atemschutzgerät verwenden. Bei unzureichender Belüftung Atemschutz.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flash Point
- 19°C
Ph
---
Dynamic Viscosity
---
Cloud Point
---
Physical State
flüssig
Decomposition Temperature
---
Crystallisation Point
---
Odor Threshold
---
Molecular Weight
---
Vapor Pressure
247 mbar
Colour Intensity
---
Relative Evaporation Rate
---
Metal Corrosion
---
Solubility In Fat
---
Appearance
---
Softening Point
---
Upper Explosive Limit
13,0 Vol %
Kinematic Viscosity
---
Explosive Limits
---
Partition Coefficient
---
Colour
gemäß Produktbezeichnung
Relative Density
---
Solubility In Water
nicht bzw. wenig mischbar
Flammability
---
Freezing Point
---
Bulk Density
---
Boiling Point
> 35°C
State Under Standard Conditions
---
Form
flüssig
Vapor Density
---
Solubility
---
Odor
charakteristisch
Density
0,9 g/cm³
Lower Explosive Limit
0,6 Vol %
Properties Status
---
Evaporation Rate
---
Melting Point
Nicht anwendbar
Solidification Point
---
Physical State Data
liquid
Auto Ignition Temperature
460°C
Voc Content
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Keine gefährlichen Reaktionen bekannt

Avoid

Keine Zersetzung bei bestimmungsgemäßer Verwendung.

Decomposition

Keine gefährlichen Zersetzungsprodukte bekannt.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Darf nicht zusammen mit Hausmüll entsorgt werden.

Waste Codes

55905 Leim- und Klebemittel, nicht ausgehärtet national code
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1133
Shipping Name
Klebstoff
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Das Produkt ist nach EG-Richtlinien/GetStoffV eingestuft und gekennzeichnet.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Armaflex-Kleber 520?

The signal word is na: r-phrases.

What is the physical form of Armaflex-Kleber 520?

Armaflex-Kleber 520 is a flüssig with gemäß produktbezeichnung color. It has charakteristisch odor.

What is the melting point of Armaflex-Kleber 520?

The melting point is Nicht anwendbar and the boiling point is > 35°C.