NextSDS Logo
Safety Data Sheet DE

Q8 Mahler G10 SAE 40

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Q8 Mahler G10 SAE 40

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Gasmotorenöl

Manufacturers & Suppliers

K

Kuwait Petroleum Companies in the Benelux

distributor

Petroleumkaai 7, 2020 Antwerp, Belgium

+32 3 247 38 11

K

Kuwait Petroleum Belgium N.V./S.A.

manufacturer

Petroleumkaai 7, B-2020 Antwerp, Belgium

Q

Q8Oils Italia S.r.l.

manufacturer

Via Volpedo 2, 15050 Castellar Guidobono (AL), Italy

Emergency Contacts

Emergency Contact

0800 000 7801

Emergency Contact

+49 89 220 61012

Emergency Contact

+44 (0) 1235 239 670

Emergency Contact

+44 (0) 1865 407 333

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Stark raffiniertes Mineralöl (C15 - C50) --- 75 - 90% No
Stark raffiniertes Mineralöl (C15 - C50) --- 5% Yes
Verzweigtkettiges Calciumalkylphenatsulfid --- 3% Yes
bis(Nonylphenyl)amine EC: 701-385-4 36878-20-3 3% Yes
Reaction mass von Isomeren aus C7-9-Alkyl-3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionat EC: 406-040-9 125643-61-0 3% Yes

Die in diesem Produkt enthaltenen mineralischen Grundöle sind stark raffiniert und enthalten weniger als 3 % DMSO-Extrakt gemäß der IP 346-Methode und sind daher gemäß der Verordnung (EG) Nr. 1272/2008, Anmerkung L, nicht als krebserregend eingestuft.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Die betroffene Person an die frische Luft bringen und in einer Position ruhigstellen, die das Atmen erleichtert. Bei nicht vorhandener oder unregelmäßiger Atmung oder beim Auftreten eines Atemstillstands ist durch ausgebildetes Personal eine künstliche Beatmung oder Sauerstoffgabe einzuleiten. Bei Bewusstlosigkeit in stabile Seitenlage bringen und sofort ärztliche Hilfe hinzuziehen. Atemwege offen halten. Eng anliegende Kleidungsstücke (z. B. Kragen, Krawatte, Gürtel oder Bund) lockern.

Symptoms: Keine spezifischen Daten.

Skin contact

Haut gründlich mit Seife und Wasser reinigen oder zugelassenes Hautreinigungsmittel verwenden. Verschmutzte Kleidung und Schuhe ausziehen. Kleidung vor erneutem Tragen waschen. Schuhe vor der Wiederverwendung gründlich reinigen.

Symptoms: Reizung, Austrocknung, Rissbildung

Eye contact

Augen sofort mit reichlich Wasser spülen und gelegentlich die oberen und unteren Augenlider anheben. Auf Kontaktlinsen prüfen und falls vorhanden entfernen. Mindestens 10 Minuten lang ständig spülen.

Symptoms: Keine spezifischen Daten.

Ingestion

Den Mund mit Wasser ausspülen. Gebissprothese falls vorhanden entfernen. Wurde der Stoff verschluckt und ist die betroffene Person bei Bewusstsein, kleine Mengen Wasser zu trinken geben. Bei Übelkeit nicht weiter trinken lassen, da Erbrechen gefährlich sein kann. Kein Erbrechen herbeiführen außer bei ausdrücklicher Anweisung durch medizinisches Personal. Sollte Erbrechen eintreten, den Kopf tief halten, damit das Erbrochene nicht in die Lungen eindringt. Niemals einer bewusstlosen Person etwas durch den Mund verabreichen. Bei Bewusstlosigkeit in stabile Seitenlage bringen und sofort ärztliche Hilfe hinzuziehen. Atemwege offen halten. Eng anliegende Kleidungsstücke (z. B. Kragen, Krawatte, Gürtel oder Bund) lockern.

Symptoms: Keine spezifischen Daten.

Immediate Medical Attention

Einen Arzt verständigen (Augenkontakt). Ärztliche Hilfe hinzuziehen, wenn die gesundheitlichen Beeinträchtigungen anhalten oder schwerwiegend sind (Inhalativ, Verschlucken). Beim Auftreten von Symptomen einen Arzt aufsuchen (Hautkontakt). Bei Bewusstlosigkeit sofort ärztliche Hilfe hinzuziehen.

Medical Treatment

Die betroffene Person muss möglicherweise 48 Stunden unter ärztlicher Beobachtung bleiben.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Löschpulver, CO₂, alkoholresistenten Schaum oder Wassersprühstrahl verwenden.

Unsuitable media

Keinen Wasserstrahl verwenden.

Specific hazards

Bei Erwärmung oder Feuer tritt ein Druckanstieg auf, und der Behälter kann platzen.

Instructions

Im Brandfall den Ort des Geschehens umgehend abriegeln und alle Personen aus dem Gefahrenbereich evakuieren. Es sollen keine Maßnahmen ergriffen werden, die mit persönlichem Risiko einhergehen oder nicht ausreichend trainiert wurden.

Firefighter Protection

Feuerwehrleute sollten angemessene Schutzkleidung und umluftunabhängige Atemgeräte mit vollem Gesichtsschutz tragen, die im Überdruckmodus betrieben werden.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Umgebung evakuieren. Nicht benötigtem und ungeschütztem Personal den Zugang verwehren. Verschüttete Substanz nicht berühren oder betreten. Einatmen von Dampf oder Nebel vermeiden.

Small spill

Undichtigkeit beseitigen, wenn gefahrlos möglich. Behälter aus dem Austrittsbereich entfernen. Mit inertem Material absorbieren und in einen geeigneten Entsorgungsbehälter geben. Über ein anerkanntes Abfallbeseitigungsunternehmen entsorgen.

Large spill

Undichtigkeit beseitigen, wenn gefahrlos möglich. Behälter aus dem Austrittsbereich entfernen. Eintritt in Kanalisation, Gewässer, Keller oder geschlossene Bereiche vermeiden. Ausgetretenes Material in eine Abwasserbehandlungsanlage spülen oder folgendermaßen vorgehen. Über ein anerkanntes Abfallbeseitigungsunternehmen entsorgen. Ausgetretenes Material mit unbrennbarem Aufsaugmittel (z.B. Sand, Erde, Vermiculite, Kieselgur) eingrenzen und zur Entsorgung nach den örtlichen Bestimmungen in einen dafür vorgesehenen Behälter geben.

Environmental

Vermeiden Sie die Verbreitung und das Abfließen von freigesetztem Material sowie den Kontakt mit dem Erdreich, Gewässern, Abflüssen und Abwasserleitungen.

Cleanup methods

Mit inertem Material absorbieren und in einen geeigneten Entsorgungsbehälter geben.

Materials: Inertes Material, unbrennbares Aufsaugmittel (Sand, Erde, Vermiculite, Kieselgur)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Geeignete Schutzausrüstung anlegen (siehe Abschnitt 8).

Storage

Nur im Originalbehälter aufbewahren. Vor direktem Sonnenlicht schützen. Nur in trockenen, kühlen und gut belüfteten Bereichen aufbewahren. Behälter bis zur Verwendung dicht verschlossen und versiegelt halten. Behälter, welche geöffnet wurden, sorgfältig verschließen und aufrecht lagern, um das Auslaufen zu verhindern. Nicht in unbeschrifteten Behältern aufbewahren.

Hygiene

Das Essen, Trinken und Rauchen ist in Bereichen, in denen diese Substanz verwendet, gelagert oder verarbeitet wird, zu verbieten. Die mit der Substanz umgehenden Personen müssen sich vor dem Essen, Trinken oder Rauchen die Hände und das Gesicht waschen. Kontaminierte Kleidung und Schutzausrüstung vor dem Betreten des Essbereichs entfernen. Siehe Abschnitt 8 für weitere Angaben zu Hygienemaßnahmen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Gute übliche Raumluftung sollte zur Begrenzung der Exposition der Arbeiter gegenüber Luftschadstoffen ausreichen.

Hands

Beim Umgang mit chemischen Produkten müssen immer chemikalienbeständige, undurchlässige und einer anerkannten Norm entsprechende Handschuhe getragen werden, wenn eine Risikobeurteilung dies erfordert. Geeignete nach EN374 geprüfte Schutzhandschuhe tragen. Empfohlen: < 1 Stunde (Durchdringungszeit): Nitrilkautschuk 0.17 mm. Mitarbeiter Haut-Pflege-Programme anbieten.

Eyes

Wenn die Risikobeurteilung dies erfordert, sollten Schutzbrillen getragen werden, die einer anerkannten Norm entsprechen, um die Exposition gegenüber Flüssigkeitsspritzern, Nebeln, Gasen oder Stäuben zu vermeiden. Wenn ein Kontakt möglich ist, dann muss folgende Schutzausrüstung getragen werden, es sei denn, die Beurteilung erfordert einen höheren Schutzgrad: Schutzbrille mit Seitenblenden.

Respiratory

Wählen Sie – basierend auf der Gefahr und dem Risiko einer Exposition – die Atemschutzmaske aus, die die entsprechenden Standards erfüllt und über die entsprechenden Zertifikationen verfügt. Atemschutzmasken müssen gemäß dem Atemschutzprogramm benutzt werden, um einen richtigen Sitz, eine adäquate Schulung und andere wichtige Verwendungsaspekte sicherstellen zu können. Empfohlen: Siedepunkt > 65 °C: A1; Siedepunkt < 65 °C: AX1; heißem Material: A1P2. Gas- und Kombinationsfilterpatronen sollten der europäischen Norm EN14387 entsprechen.

Skin/Body

Vor dem Umgang mit diesem Produkt sollte die persönliche Schutzausrüstung auf der Basis der durchzuführenden Aufgabe und den damit verbundenen Risiken ausgewählt und von einem Spezialisten genehmigt werden. Geeignetes Schuhwerk und zusätzliche Hautschutzmaßnahmen auf Basis der durchzuführenden Aufgabe und der damit verbundenen Gefahren wählen, und vorgängig durch einen Fachmann genehmigen lassen.

Environmental

Emissionen von Belüftungs- und Prozessgeräten sollten überprüft werden, um sicherzugehen, dass sie den Anforderungen der Umweltschutzgesetze genügen. In einigen Fällen werden Abluftwäscher, Filter oder technische Änderungen an den Prozessanlagen erforderlich sein, um die Emissionen auf akzeptable Werte herabzusetzen.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
---
State Under Standard Conditions
---
Appearance
Hell
Colour
Braun
Colour Intensity
---
Form
---
Odor
Schwach
Odor Threshold
Nicht verfügbar.
Ph
Nicht anwendbar.
Melting Point
Nicht anwendbar.
Boiling Point
>300°C (>572°F)
Flash Point
Offenem Tiegel: 250°C (482°F) [ASTM D 92]
Freezing Point
-12°C (10.4°F) [ASTM D 97]
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
<0.01 kPa (<0.075006 mm Hg)
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.89 g/cm³ [15°C (59°F)] [ASTM D 4052]
Flammability
Nicht anwendbar.
Upper Explosive Limit
Nicht verfügbar.
Lower Explosive Limit
Nicht verfügbar.
Explosive Limits
---
Auto Ignition Temperature
>300°C (>572°F)
Decomposition Temperature
>300°C
Solubility
---
Partition Coefficient
Nicht anwendbar.
Solubility In Water
kaltes Wasser: Nicht löslich, heißem Wasser: Nicht löslich
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematisch (40°C (104°F)): 120 mm²/s (120 cSt) [ASTM D 445] Kinematisch (100°C (212°F)): 13.3 mm²/s (13.3 cSt) [ASTM D 445]
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Das Produkt ist stabil.

Reactivity

Für dieses Produkt oder seine Inhaltsstoffe liegen keine speziellen Daten bezüglich der Reaktivität vor.

Hazardous reactions

Unter normalen Lagerbedingungen und bei normalem Gebrauch treten keine gefährlichen Reaktionen auf.

Avoid

Keine spezifischen Daten.

Incompatible

Stark oxidierende Stoffe

Decomposition

Unter normalen Lagerungs- und Gebrauchsbedingungen sollten keine gefährlichen Zerfallsprodukte gebildet werden.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxizität

Name des Produkts / Inhaltsstoffs

12.1 Toxizität

Stark raffiniertes Mineralöl (C15 - C50) * - Nicht eingestuft. ## Resultat Akut - NEL - Frischwasser Fisch, Prüfung der akuten Toxizität Fisch - Pimephales promelas ≥100 mg/l [96 Stunden] Akut - NEL - Frischwasser Daphnia sp. Akuter Immobilisierungstest und Reproduktionstest Daphnie - Daphnia Magma >10000 mg/l [48 Stunden] Chronisch - NEL - Frischwasser Daphnia Magna Fortpflanzungstest Daphnie - Daphnia magna 10 mg/l [21 Tage] Effekt: Reproduktion Akut - NEL - Frischwasser Alge, Wachstumshemmungstest Algen >100 mg/l [72 Stunden] Effekt: (Wachstumsrate)

12.1 Toxizität

Stark raffiniertes Mineralöl (C15 - C50) * - H304 Akut - NEL - Frischwasser Fisch, Prüfung der akuten Toxizität Fisch - Pimephales promelas ≥100 mg/l [96 Stunden] Akut - NEL - Frischwasser Daphnia sp. Akuter Immobilisierungstest und Reproduktionstest Daphnie - Daphnia Magma >10000 mg/l [48 Stunden] Chronisch - NEL - Frischwasser Daphnia Magna Fortpflanzungstest Daphnie - Daphnia magna 10 mg/l [21 Tage] Effekt: Reproduktion Akut - NEL - Frischwasser Alge, Wachstumshemmungstest Algen >100 mg/l [72 Stunden] Effekt: (Wachstumsrate)

12.2 Persistenz und Abbaubarkeit

Nicht verfügbar.

Nicht verfügbar.

12.2 Persistenz und Abbaubarkeit

| Name des Produkts / Inhaltsstoffs | Aquatische Halbwertszeit | Photolyse | Biologische Abbaubarkeit | | --- | --- | --- | --- | | Stark raffiniertes Mineralöl (C15 - C50) * - Nicht eingestuft. | - | - | Inhärent |

12.2 Persistenz und Abbaubarkeit

| Name des Produkts / Inhaltsstoffs | Aquatische Halbwertszeit | Photolyse | Biologische Abbaubarkeit | | --- | --- | --- | --- | | Stark raffiniertes Mineralöl (C15 - C50) * - H304 | - | - | Inhärent |

12.3 Bioakkumulationspotenzial

| Name des Produkts / Inhaltsstoffs | LogPow | BCF | Potential | | --- | --- | --- | --- | | bis(Nonylphenyl)amine | 3.64 bis 7.02 | 1730 [METI-Leitfaden (Konzentrationstest an chemischen Stoffen in Fischen)] | Hoch |

12.3 Bioakkumulationspotenzial

| Name des Produkts / Inhaltsstoffs | LogPow | BCF | Potential | | --- | --- | --- | --- | | Reaction mass von Isomeren aus C7-9-Alkyl-3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionat | 9.2 | 260 [OECD 305] | Niedrig |

12.4 Mobilität im Boden

Verteilungskoeffizient Boden/Wasser Nicht verfügbar. Mobilität : Nicht verfügbar.

Nicht verfügbar.

Ergebnisse der PMT- und vPvM-Beurteilung

| Name des Produkts / Inhaltsstoffs | PMT | P | M | T | vPvM | vP | vM | | --- | --- | --- | --- | --- | --- | --- | --- | | Stark raffiniertes Mineralöl (C15 - C50) * - Nicht eingestuft. | Nein | Nein | Nein | Nein | Nein | Nein | Nein | | Stark raffiniertes Mineralöl (C15 - C50) * - H304 | Nein | Nein | Nein | Nein | Nein | Nein | Nein | | Verzweigtkettiges Calciumalkylphenatsulfid bis(Nonylphenyl)amine | Nein | Nein | Nein | Nein | Nein | Nein | Nein | | Reaction mass von Isomeren aus C7-9-Alkyl-3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionat | Nein | Nein | Nein | Nein | Nein | Nein | Nein | Schlussfolgerung / Zusammenfassung : Das Produkt erfüllt nicht die Kriterien, um als PMT oder vPvM betrachtet zu werden.

Das Produkt erfüllt nicht die Kriterien, um als PMT oder vPvM betrachtet zu werden.

12.5 Ergebnisse der PBT- und vPvB-Beurteilung

Verordnung (EG) Nr. 1907/2006 [REACH] | Name des Produkts / Inhaltsstoffs | PBT | P | B | T | vPvB | vP | vB | | --- | --- | --- | --- | --- | --- | --- | --- | | Stark raffiniertes Mineralöl (C15 - C50) * - Nicht eingestuft. | Nein | N/A | N/A | Nein | N/A | N/A | N/A | | Stark raffiniertes Mineralöl (C15 - C50) * - H304 | Nein | N/A | N/A | Nein | N/A | N/A | N/A | | Verzweigtkettiges Calciumalkylphenatsulfid bis(Nonylphenyl)amine | Nein | N/A | N/A | Nein | N/A | N/A | N/A | | Reaction mass von | Nein | N/A | Nein | Nein | Nein | N/A | Nein | Verordnung (EG) Nr. 1272/2008 [CLP] | Name des Produkts / Inhaltsstoffs | PBT | P | B | T | vPvB | vP | vB | | --- | --- | --- | --- | --- | --- | --- | --- | | Stark raffiniertes Mineralöl (C15 - C50) * - Nicht eingestuft. | Nein | Nein | Nein | Nein | Nein | Nein | Nein | | Stark raffiniertes Mineralöl (C15 - C50) * - H304 | Nein | Nein | Nein | Nein | Nein | Nein | Nein | | Verzweigtkettiges Calciumalkylphenatsulfid bis(Nonylphenyl)amine | Nein | Nein | Nein | Nein | Nein | Nein | Nein | | Reaction mass von Isomeren aus C7-9-Alkyl-3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionat | Nein | Nein | Nein | Nein | Nein | Nein | Nein | Schlussfolgerung / Zusammenfassung Verordnung (EG) Nr. 1272/2008 [CLP] : Das Produkt erfüllt nicht die Kriterien, um als PBT oder vPvB betrachtet zu werden.

Das Produkt erfüllt nicht die Kriterien, um als PBT oder vPvB betrachtet zu werden.

12.6 Endokrinschädliche Eigenschaften

Nicht verfügbar. Schlussfolgerung / Zusammenfassung [Produkt] : Das Produkt erfüllt nicht die Kriterien, die gemäß den Kriterien der Verordnung (EG) Nr. 1907/2006 oder der Verordnung (EG) Nr. 1272/2008 als endokrin wirkend angesehen werden können.

Das Produkt erfüllt nicht die Kriterien, die gemäß den Kriterien der Verordnung (EG) Nr. 1907/2006 oder der Verordnung (EG) Nr. 1272/2008 als endokrin wirkend angesehen werden können.

12.7 Andere schädliche Wirkungen

Keine besonderen Wirkungen oder Gefahren bekannt.

Keine besonderen Wirkungen oder Gefahren bekannt.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Die Abfallerzeugung sollte nach Möglichkeit vermieden oder minimiert werden. Die Entsorgung dieses Produkts sowie seiner Lösungen und Nebenprodukte muss jederzeit unter Einhaltung der Umweltschutzanforderungen und Abfallbeseitigungsgesetze sowie den Anforderungen der örtlichen Behörden erfolgen. Überschüsse und nicht zum Recyclen geeignete Produkte über ein anerkanntes Abfallbeseitigungsunternehmen entsorgen.

Waste Codes

13 02 05* nichtchlorierte Maschinen-, Getriebe- und Schmieröle auf Mineralölbasis EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Transport auf dem Werksgelände: nur in geschlossenen Behältern transportieren, die senkrecht und fest stehen. Personen, die das Produkt transportieren, müssen für das richtige Verhalten bei Unfällen, Auslaufen oder Verschüttungen unterwiesen sein.

IMDG

Transport auf dem Werksgelände: nur in geschlossenen Behältern transportieren, die senkrecht und fest stehen. Personen, die das Produkt transportieren, müssen für das richtige Verhalten bei Unfällen, Auslaufen oder Verschüttungen unterwiesen sein.

IATA

Transport auf dem Werksgelände: nur in geschlossenen Behältern transportieren, die senkrecht und fest stehen. Personen, die das Produkt transportieren, müssen für das richtige Verhalten bei Unfällen, Auslaufen oder Verschüttungen unterwiesen sein.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Erfüllt Verordnung (EG) Nr. 1907/2006 (REACH), Anhang II, abgeändert gemäß Verordnung (EU) 2020/878

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Q8 Mahler G10 SAE 40?

The signal word is no signal word.

What is the physical form of Q8 Mahler G10 SAE 40?

Q8 Mahler G10 SAE 40 is a liquid appearing as hell with braun color. It has schwach odor.

What is Q8 Mahler G10 SAE 40 used for?

Gasmotorenöl

What is the melting point of Q8 Mahler G10 SAE 40?

The melting point is Nicht anwendbar. and the boiling point is >300°C (>572°F).