01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Holzleim D3
Product Code
0079_000

Regulatory Identifiers

CAS Number
N/A

Identified Uses

PC1 - PC 1 - Klebstoffe, Dichtstoffe SU22 - Gewerbliche Verwendungen: Öffentlicher Bereich (Verwaltung, Bildung, Unterhaltung, Dienstleistungen, Handwerk) SU21 - Verbraucherverwendungen: Private Haushalte (= Allgemeinheit = Verbraucher)

Manufacturers & Suppliers

PUFAS Werk KG logo

PUFAS Werk KG

manufacturer

Im Schedetal 1, 34346 Hann. Münden

+49 (0)5541 7003-01

http://www.pufas.de

Emergency Contacts

Emergency Contact

+49 (0)5541 7003-41/-64

Mo-Do 8 - 16 Uhr, Fr 8 - 12.30 Uhr

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Bestehend aus: Kunststoffdispersion, Wasser, Konservierungsmittel und Hilfsmittel

Chemical Name CAS Number Concentration Hazardous
PROPYLENCARBONAT EC: 203-572-1 108-32-7 1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bei Reizung der Atemwege Arzt aufsuchen.

Skin contact

Bei Berührung mit der Haut sofort abwaschen mit viel Wasser und Seife.

Eye contact

Bei Augenkontakt die Augen bei geöffneten Lidern ausreichend lange mit Wasser spülen, dann sofort Augenarzt konsultieren.

Ingestion

Sofort Mund ausspülen und reichlich Wasser nachtrinken. In allen Zweifelsfällen oder wenn Symptome vorhanden sind, ärztlichen Rat einholen.

Immediate Medical Attention

In allen Zweifelsfällen oder wenn Symptome vorhanden sind, ärztlichen Rat einholen. Bei Augenkontakt sofort Augenarzt konsultieren.

Medical Treatment

Keine

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Das Produkt selbst brennt nicht. Löschmaßnahmen auf die Umgebung abstimmen.

Specific hazards

Explosions- und Brandgase nicht einatmen.

Firefighter Protection

Explosions- und Brandgase nicht einatmen. Geeignetes Atemschutzgerät benutzen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Es sind keine besonderen Maßnahmen erforderlich.

Environmental

Nicht in die Kanalisation oder Gewässer gelangen lassen.

Cleanup methods

Mit inertem Aufsaugmittel aufnehmen

Materials: inertem Aufsaugmittel

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Berührung mit der Haut und den Augen vermeiden. Nahrungsmittel, Getränke und Futtermittel fernhalten.

Storage

Nicht im Freien lagern. Stets in Behältern aufbewahren, die dem Originalgebinde entsprechen. Hinweise auf dem Etikett beachten. Vor Hitze und direkter Sonneneinstrahlung schützen. Sicherheitshinweise und Gebrauchsanweisung auf dem Gebinde beachten.

Fire prevention

Es sind keine besonderen Maßnahmen erforderlich.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handschutz ist nicht erforderlich

Eyes

Augenschutz: nicht erforderlich.

Respiratory

Normalerweise kein persönlicher Atemschutz notwendig.

Skin/Body

Geschlossene Arbeitskleidung tragen. Beschmutzte, getränkte Kleidung ausziehen.

Environmental

Siehe auch Kapitel 6 und 12.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
flüssig: viskos
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
weiß
Colour Intensity
---
Form
---
Odor
charakteristisch
Odor Threshold
---
Ph
ca. 3
Melting Point
ca. 0 °C ( 1013 hPa )
Boiling Point
nicht anwendbar ( 1013 hPa )
Flash Point
keine/keiner Brookfield
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
ca. 23 hPa ( 20 °C )
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
ca. 1,1 g/cm³ ( 20 °C )
Flammability
---
Upper Explosive Limit
Keine Daten verfügbar
Lower Explosive Limit
Keine Daten verfügbar
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
12000 - 18000 mPa*s ( 20 °C )
Kinematic Viscosity
nicht relevant ( 40 °C )
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Bei Anwendung der empfohlenen Vorschriften zur Lagerung und Handhabung stabil (siehe Abschnitt 7).

Reactivity

Es liegen keine Informationen vor.

Hazardous reactions

Es liegen keine Informationen vor.

Avoid

Es liegen keine Informationen vor.

Incompatible

Keine bei bestimmungsgemäßer Verwendung.

Decomposition

Keine bei bestimmungsgemäßer Verwendung.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxizität

Es liegen keine Informationen vor. ### Verhalten in Kläranlagen Bei sachgemäßer Einleitung geringer Konzentrationen in adaptierte biologische Kläranlagen sind Störungen der Abbauaktivität von Belebtschlamm nicht zu erwarten.

Es liegen keine Informationen zur Toxizität vor. Störungen der Abbauaktivität von Belebtschlamm sind bei sachgemäßer Einleitung geringer Konzentrationen nicht zu erwarten.

12.2 Persistenz und Abbaubarkeit

Es liegen keine Informationen vor.

Es liegen keine Informationen vor.

12.3 Bioakkumulationspotenzial

Es liegen keine Informationen vor.

Es liegen keine Informationen vor.

12.4 Mobilität im Boden

Es liegen keine Informationen vor.

Es liegen keine Informationen vor.

12.5 Ergebnisse der PBT- und vPvB-Beurteilung

Es liegen keine Informationen vor.

Es liegen keine Informationen vor.

12.6 Andere schädliche Wirkungen

Es liegen keine Informationen vor.

12.7 Zusätzliche ökotoxikologische Informationen

Nicht in die Kanalisation oder Gewässer gelangen lassen. Wassergefährdungsklasse 1: schwach wassergefährdend

Hinweise zum Umweltschutz und Einstufung in Wassergefährdungsklasse 1.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Unter Beachtung der behördlichen Vorschriften beseitigen. Oder nach Eintrocknung / Aushärtung zusammen mit Hausmüll ablagern.

Disposal

Unter Beachtung der behördlichen Vorschriften beseitigen. Oder nach Eintrocknung / Aushärtung zusammen mit Hausmüll ablagern.

Waste Codes

08 04 10 Klebstoff- und Dichtmassenabfälle mit Ausnahme derjenigen, die unter 08 04 09 fallen EAK/AVV
17 09 04 gemischte Bau- und Abbruchabfälle mit Ausnahme derjenigen, die unter 17 09 01, 17 09 02 und 17 09 03 fallen EAK/AVV
15 01 02 Verpackungen aus Kunststoff EAK/AVV
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Holzleim D3?

The signal word is no signal word.

What is the physical form of Holzleim D3?

Holzleim D3 is a flüssig: viskos with weiß color. It has charakteristisch odor.

What is Holzleim D3 used for?

PC1 - PC 1 - Klebstoffe, Dichtstoffe SU22 - Gewerbliche Verwendungen: Öffentlicher Bereich (Verwaltung, Bildung, Unterhaltung, Dienstleistungen, Handwerk) SU21 - Verbraucherverwendungen: Private Haushalte (= Allgemeinheit = Verbraucher)

What is the melting point of Holzleim D3?

The melting point is ca. 0 °C ( 1013 hPa ) and the boiling point is nicht anwendbar ( 1013 hPa ).