NextSDS Logo
Safety Data Sheet DE

Galliumarsenid kompakt

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Galliumarsenid kompakt
Chemical Name
Galliumarsenid
Synonyms
Ingot, Wafer, Fragmente

Regulatory Identifiers

CAS Number
N/A
REACH No.
01-2119561669-23

Identified Uses

„III - V“ – Verbindungshalbleiter - Substrate für die Halbleiterindustrie (Hochfrequenzanwendungen, Optoelektronik)

Uses advised against

keine

Manufacturers & Suppliers

F

Freiberger Compound Materials GmbH (FCM)

manufacturer

Am Junger Löwe Schacht 5, D - 09599 Freiberg

+49 3731 280 - 0

Emergency Contacts

FCM GmbH

+49 3731 280 – 0

werktags von 08.00 Uhr – 16.00 Uhr

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Carc. Cat. 1B
STOT RE Cat. 1
Repr. Cat. 1B

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Galliumarsenid EC: 215-114-8 1303-00-0 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

Normale betriebliche Hygienemaßnahmen z.B. mit Wasser und Seife reinigen.

Medical Treatment

keine

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Keine besonderen Löschmittel notwendig, Löschmaßnahmen auf Umgebung abstimmen.

Unsuitable media

keine Ausnahme

Specific hazards

Arsenoxidhaltige Brandgase und Zersetzungsprodukte können entstehen.

Instructions

umgebungsunabhängige Atemschutzausrüstung benutzen

Firefighter Protection

umgebungsunabhängige Atemschutzausrüstung benutzen

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Die bei der mechanischen Bearbeitung entstehenden Stäube und chemischen Verbindungen unterliegen den lokal gültigen Vorschriften (z.B. Arbeitsschutz).

Environmental

Von GaAs in seiner kompakten Form geht keine Umweltgefährdung aus. Die bei der mechanischen Bearbeitung entstehenden Stäube und chemischen Verbindungen unterliegen den lokal gültigen Vorschriften.

Cleanup methods

mechanische Aufnahme

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Allgemeine Hygienemaßnahmen einhalten (siehe auch Abschnitte 8.1; 8.2 und 10.1 - 10.4)

Storage

Material trocken lagern, Behälter verschließen

Hygiene

Allgemeine Hygienemaßnahmen einhalten

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Bearbeitung/Prozesse möglichst in geschlossenen Apparaturen, ggf. Absaugung am Entstehungsort; Mechanische Bearbeitungsprozesse möglichst nass, Anlagenabsaugung vorsehen; Absaugvorrichtungen/Abdeckungen/Nassbearbeitung bei manuellen Arbeitsschritten

Hands

100 % Nitrilpolymer (0,1 mm dick) – reinraumtauglich; Naturlatex (0,5 mm dick); ggf. mit Schnittschutz. Durchdringungszeit des Handschuhmaterials: abhängig von der mechanischen Einwirkung sowie zusätzlichen chemischen Belastungen. Schutzhandschuhe sollten bei ersten Abnutzungserscheinungen ersetzt werden.

Eyes

abhängig vom Arbeitsplatz (Schutzbrille, Vollmaske nur bei Stäuben, Dämpfen)

Respiratory

abhängig vom Arbeitsplatz Vollschutz- oder Halbmaske; Stäube: Partikelfilter P3 (Kennfarbe weiß); Dämpfe/Gase: Gasfiltertyp B (Kennfarbe grau)

Skin/Body

abhängig vom Arbeitsplatz (Kittel, Anzug, Overall)

Environmental

Abluft: Gezielte Erfassung der GaAs-haltigen Abluft – die Reinigung erfolgt über einen mehrstufigen Partikelfilter EU 7 (H7) und EU 14 (H14). Abwasser: Erfassung der GaAs-haltigen Abwasser – Reinigung in einer Abwasserbehandlungsanlage (Sammlung, Flockung, Neutralisation, Sedimentation, Fest-Flüssig-Trennung) – gereinigtes Wasser Einleitung in die Kanalisation, Sedimentationsschlamm – Deponierung

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
fest
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
grau, metallisch glänzend
Colour Intensity
---
Form
fest (Ingot, Wafer, Fragmente)
Odor
ohne
Odor Threshold
---
Ph
entfällt
Melting Point
1239.85°C bei 1013 hPa
Boiling Point
---
Flash Point
nicht entzündbar
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
entfällt
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
5,33 g/cm³ bei 20 °C
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
in Spuren ab ca. 300°C
Solubility
schwer löslich in Wasser: 25,2 µg/l; unlöslich in gebräuchlichen organischen Lösungsmitteln
Partition Coefficient
---
Solubility In Water
schwer löslich in Wasser: 25,2 µg/l
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

stabil unter Normalbedingungen und Normalverwendungen

Reactivity

Bei der Lagerung in der Originalverpackung sind keine Unverträglichkeiten mit dem Verpackungsmaterial zu erwarten.

Hazardous reactions

Bei chemischer Behandlung können giftige arsenhaltige Verbindungen entstehen; bei der Auflösung in Säuren kann bei gleichzeitiger Bildung von Wasserstoff Arsin frei werden.

Avoid

erhitzen über 300 °C (Beginn der Zersetzung)

Incompatible

Säuren, Laugen

Decomposition

Bei thermischer Zersetzung entsteht Arsen bei Luftabschluss, an Luft As₂O₃.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Ökotoxizität

Eine Einstufung wird als nicht notwendig erachtet. Es ist anzunehmen, dass von GaAs in seiner kompakten Form keine Konzentrationen im Umweltkompartiment Wasser mit toxischer Wirkung auf aquatische Organismen erreicht werden.

Eine Einstufung wird als nicht notwendig erachtet. Es ist anzunehmen, dass von GaAs in seiner kompakten Form keine Konzentrationen im Umweltkompartiment Wasser mit toxischer Wirkung auf aquatische Organismen erreicht werden.

12.2 Persistenz und Abbaubarkeit

Galliumarsenid ist nicht abbaubar (anorganische Elemente)

Galliumarsenid ist nicht abbaubar (anorganische Elemente)

12.3 Bioakkumulation (Nahrungsmittelkette): ist für Galliumarsenid nicht zu erwarten

12.3 Bioakkumulation (Nahrungsmittelkette): ist für Galliumarsenid nicht zu erwarten

Bioakkumulation ist für Galliumarsenid nicht zu erwarten.

12.4 Mobilität im Boden

12.4 Mobilität im Boden: nicht bekannt, sowohl Ga als auch As kommen in Spuren geogen in der Umwelt vor

Die Mobilität im Boden ist nicht bekannt, da Gallium (Ga) und Arsen (As) geogen in Spuren in der Umwelt vorkommen.

12.5 Ergebnisse der PBT- und vPvB-Beurteilung: nicht als PBT oder vPvB identifiziert

12.5 Ergebnisse der PBT- und vPvB-Beurteilung: nicht als PBT oder vPvB identifiziert

Der Stoff wurde nicht als PBT oder vPvB identifiziert.

12.6 Andere schädliche Wirkungen

12.6 Andere schädliche Wirkungen: keine weiteren Angaben

keine weiteren Angaben

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Entsprechend den geltenden Vorschriften als gefährlichen Abfall behandeln.

Disposal

Nach Rücksprache Rücklieferung an den Hersteller möglich. GaAs-haltige Rückstände nicht unbehandelt über das Abwasser entsorgen.

Waste Codes

060403 Arsenhaltige Abfälle AVV
190205 Metallhydroxidschlämme und andere Schlämme aus der Metallfällung AVV
150202 Aufsaug- und Filtermaterialien, Wischtücher und Schutzkleidung, die durch gefährliche Stoffe verunreinigt sind AVV
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Hinweise zur Beschäftigungsbeschränkung: Beschäftigungsbeschränkungen für Jugendliche beachten. Gebrauch nur durch technisch qualifizierte Personen.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Galliumarsenid kompakt known by?

Galliumarsenid kompakt is also known as: Ingot, Wafer, Fragmente

What is the hazard signal word for Galliumarsenid kompakt?

The signal word is no signal word.

What is the physical form of Galliumarsenid kompakt?

Galliumarsenid kompakt is a fest with grau, metallisch glänzend color. It has ohne odor.

What is the solubility of Galliumarsenid kompakt?

schwer löslich in Wasser: 25,2 µg/l; unlöslich in gebräuchlichen organischen Lösungsmitteln

What is Galliumarsenid kompakt used for?

„III - V“ – Verbindungshalbleiter - Substrate für die Halbleiterindustrie (Hochfrequenzanwendungen, Optoelektronik)

What is the melting point of Galliumarsenid kompakt?

The melting point is 1239.85°C bei 1013 hPa .