NextSDS Logo
Safety Data Sheet DE

INTO

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
INTO
Product Code
100286E

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Sanitärreiniger

Manufacturers & Suppliers

E

Ecolab Deutschland GmbH

national supplier

Reisholzer Werftstrasse 38-42, Postfach 13 04 06, DE-40554 Düsseldorf, Germany

+49 (0)211 9893 0

Emergency Contacts

Emergency Contact

0211 98 93 700

Giftinformationszentrum-Nord (GIZ-Nord) Göttingen

0551 19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Inhaltsstoffangabe gemäß Detergentienverordnung 648/2004 EG: <5% nichtionische Tenside

Chemical Name CAS Number Concentration Hazardous
Sulfamidsäure EC: 226-218-8 5329-14-6 5 - 10% Yes
Fettalkoholethoxylate > 5EO --- 2 - 5% Yes
Ethanol EC: 200-578-6 64-17-5 1 - 2% Yes

Enthält Parfum

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Falls eingeatmet, an die frische Luft bringen.

Skin contact

Kontaminierte Haut mit reichlich Wasser abspülen.

Eye contact

Bei Augenkontakt sofort mit reichlich Wasser ausspülen. Bei Reizung einen Arzt hinzuziehen.

Ingestion

Kein Erbrechen herbeiführen außer bei ausdrücklicher Anweisung durch medizinisches Personal. Bei Verschlucken Mund mit Wasser ausspülen (nur wenn Verunfallter bei Bewußtsein ist).

Medical Treatment

Nicht verfügbar.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Im Brandfall Sprühwasser (Nebel), Schaum, Löschpulver oder Coeinsetzen.

Firefighter Protection

Feuerwehrleute müssen geeignete Schutzausrüstung tragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Unverzüglich Sicherheitskräfte kontaktieren.

Small spill

Mit reichlich fließendem Wasser spülen.

Large spill

Bei größeren Leckagen verschüttetes Produkt eindämmen oder anderweitig eingrenzen, damit kein Abfluß in Gewässer erfolgen kann. Verschüttetes Material in einen geeigneten Behälter zur Entsorgung geben.

Environmental

Vermeiden Sie die Verbreitung und das Abfließen von freigesetztem Material sowie den Kontakt mit dem Erdreich, Gewässern, Abflüssen und Abwasserleitungen.

Cleanup methods

Verschüttetes Material in einen geeigneten Behälter zur Entsorgung geben.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Nach Umgang stets die Hände gründlich mit Wasser und Seife waschen.

Storage

Behälter dicht geschlossen halten. Von Nahrungsmitteln, Getränken und Futtermitteln fernhalten. Nur im Originalbehälter aufbewahren.

Hygiene

Nach Umgang stets die Hände gründlich mit Wasser und Seife waschen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Flüssigkeit.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Farblos.
Colour Intensity
---
Form
---
Odor
Parfümartig.
Odor Threshold
---
Ph
0.6 (100%)
Melting Point
Nicht verfügbar.
Boiling Point
Nicht verfügbar.
Flash Point
> 100°C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Nicht anwendbar.
Vapor Pressure
Nicht anwendbar.
Vapor Density
Nicht verfügbar.
Relative Density
1.048 g/cm³ (20 °C)
Bulk Density
---
Density
---
Flammability
Nicht anwendbar.
Upper Explosive Limit
Nicht anwendbar.
Lower Explosive Limit
Nicht anwendbar.
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
Leicht löslich in kaltes Wasser, heißem Wasser.
Partition Coefficient
Nicht anwendbar.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stabil unter normalen Bedingungen.

Incompatible

Nicht mit anderen Produkten mischen.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Ökotoxizität

Das Produkt ist nicht kennzeichnungspflichtig bezüglich umweltgefährlicher Eigenschaften gemäss der EG Direktive 1999/45/EC.

Persistenz und Abbaubarkeit

Die in diesem Produkt enthaltenen Tenside sind gemäß den Anforderungen der Detergentienverordnung 648/2004 EG biologisch abbaubar.

Die in diesem Produkt enthaltenen Tenside sind gemäß den Anforderungen der Detergentienverordnung 648/2004 EG biologisch abbaubar.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Abfall muss vorschriftsmäßig entsorgt werden.

Disposal

Produktreste nach Möglichkeit bestimmungsgemäss aufbrauchen.

Waste Codes

200114* EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Die Zubereitung ist nicht kennzeichnungspflichtig gemäss den EU-Richtlinien.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for INTO?

The signal word is no signal word.

What is the physical form of INTO?

INTO is a flüssigkeit. with farblos. color. It has parfümartig. odor.

What is the solubility of INTO?

Leicht löslich in kaltes Wasser, heißem Wasser.

What is INTO used for?

Sanitärreiniger

What is the melting point of INTO?

The melting point is Nicht verfügbar. and the boiling point is Nicht verfügbar..