Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MICROPOSIT EC SOLVENT
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Chemische Spezialität
Manufacturers & Suppliers
Rohm and Haas Electronic Materials Europe Ltd.
national supplier
Herald Way, Coventry CV3 2RQ UK
+44 (0) 24-7665-4400
Emergency Contacts
Emergency Contact
+33 (0) 140025045
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
GHS02
GHS07
Hazard Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-Methoxy-1-methylethylacetat EC: 203-603-9 | 108-65-6 | 95 - 100% | Yes |
| 2-Methoxypropylacetat EC: 274-724-2 | 70657-70-4 | 0.25 - 0.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Aus dem Wirkungsbereich entfernen. Bei Atembeschwerden Sauerstoff verabreichen.
Symptoms: Atembeschwerden
Mit Wasser und Seife abwaschen. Wenigstens 10 Minuten lang weiterwaschen.
Symptoms: Blasenbildung oder anhaltende Rötung
Das Auge sofort wenigstens 10 Minuten lang mit viel Wasser ausspülen, das Auge dabei offenhalten.
Symptoms: Anhaltende Entzündung oder Rötung
Mund mit Wasser auswaschen. Dem Opfer 1-3 Glas Wasser zu trinken geben, um den Mageninhalt zu verdünnen.
Immediate Medical Attention
Eine sofortige ärztliche Betreuung ist notwendig (bei Einatmen). Arzt aufsuchen (bei Verschlucken).
Medical Treatment
Symptomatische Behandlung.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Wassersprühnebel, Schaum, Löschpulver oder Kohlendioxid verwenden. Behälter und Umgebung mit Wassersprühnebel kühlen.
Dieses Produkt kann bei einem Brand zur Entstehung gefährlicher Dämpfe beitragen. Dämpfe können beträchtliche Entfernungen bis zu einer Zündquelle zurücklegen und einen Flammenrückschlag verursachen.
Firefighter Protection
Vollständige Schutzkleidung und umluftunabhängiges Atemschutzgerät tragen.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Das Material am Eindringen in die Kanalisation und in Wasserläufe zu hindern versuchen. Nicht direkt in eine Wasserquelle ablassen.
Für Rückgewinnung bzw. Entsorgung in geeignete Behälter geben.
Related Products
Similar products with comparable safety profiles
SOLVENT 50
UFI: 5K2X-285Q-9000-EPUV
MICROPOSIT SURFACE COATING FSC-H
---
MICROPOSIT SURFACE COATING FSC-M
---
MICROPOSIT(TM) S1805(TM) G2 POSITIVE PHOTORESIST
---
MICROPOSIT(TM) S1818(TM) G2 POSITIVE PHOTORESIST
---
MICROPOSIT(TM) S1828(TM) G2 POSITIVE PHOTORESIST
---
AZ EBR Solvent
UFI: MT82-29DD-05SX-W453
ecosol BRITE S
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Kontakt mit Haut, Augen und Kleidung vermeiden. Den Behälter fest verschlossen halten.
Im Originalbehälter lagern. Kühl, Trocken, Gut belüftet, Vor direkter Sonneneinstrahlung geschützt, Von unverträglichen Materialien entfernt.
Gründliche Körperpflege verhindert schädliche Einwirkung.
Von Hitze, Funken, Flammen und anderen Zündquellen fernhalten.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stabil unter normalen Bedingungen.
Statische Entladung.
Oxidationsmittel
Verbrennung erzeugt.; Kohlenmonoxid,
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Abfälle und Behälter müssen in gesicherter Weise beseitigt werden.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3272
- Shipping Name
- ESTER, N.A.G. (2-Methoxy-1-methylethylacetat)
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Einstufung und Kennzeichnung entsprechen den EU-Richtlinien 67/548/EWG und 99/45/EG in der geltenden Fassung.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MICROPOSIT EC SOLVENT?
The signal word is danger.
What is the physical form of MICROPOSIT EC SOLVENT?
MICROPOSIT EC SOLVENT is a flüssig with farblos color. It has nach ether odor.
What is MICROPOSIT EC SOLVENT used for?
Chemische Spezialität
What are the hazard statements for MICROPOSIT EC SOLVENT?
This substance has 2 hazard statements:
- H225: Entzündlich.
- H319: Reizt die Augen.
What is the melting point of MICROPOSIT EC SOLVENT?
The melting point is -67 °C and the boiling point is 145 °C.