NextSDS Logo
Safety Data Sheet DE

ma-N 1400 Negativ-Photoresist Serie

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ma-N 1400 Negativ-Photoresist Serie

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

micro resist technology GmbH logo

micro resist technology GmbH

manufacturer

Koepenicker Str. 325, Haus 211, D-12555 Berlin

+49 30 65762192

http://www.microresist.de

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Reizend

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Chemische Charakterisierung (Zubereitung)

Chemical Name CAS Number Concentration Hazardous
Anisol EC: 202-876-1 100-66-3 40 - 65% Yes
2-Methoxy-1-methylethylacetat EC: 203-603-9 108-65-6 15 - 25% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Für Frischluft sorgen. Bei Atembeschwerden Sauerstoff geben. Bei Gefahr von Bewusstlosigkeit Lagerung und Transport in stabiler Seitenlage.

Symptoms: Reizung der Atemwege

Skin contact

Bei Berührung mit der Haut sofort abwaschen mit viel Wasser und Seife. Kontaminierte Kleidung wechseln.

Symptoms: Hautreizungen

Eye contact

Sofort bei geöffnetem Lidspalt 10 bis 15 Minuten mit fließendem Wasser spülen.

Ingestion

Mund gründlich mit Wasser ausspülen. Reichlich Wasser in kleinen Schlucken trinken lassen (Verdünnungseffekt).

Immediate Medical Attention

Bei Reizung der Atemwege Arzt aufsuchen. Bei Hautreizungen Arzt aufsuchen. Augenarzt aufsuchen. Sofort Arzt hinzuziehen.

Medical Treatment

Symptomatische Behandlung.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Kohlendioxid (CO2). Trockenlöschmittel. Schaum.

Unsuitable media

Wasservollstrahl.

Specific hazards

Explosions- und Brandgase nicht einatmen.

Firefighter Protection

Im Brandfall: Umluftunabhängiges Atemschutzgerät verwenden. Chemieschutzanzug tragen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Nicht in die Kanalisation oder Gewässer gelangen lassen.

Cleanup methods

Mit flüssigkeitsbindendem Material aufnehmen.

Materials: Sand, Kieselgur, Säurebinder, Universalbinder

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Nur in gut gelüfteten Bereichen verwenden. Von Zündquellen fernhalten - Nicht rauchen.

Storage

Behälter dicht geschlossen an einem gut gelüfteten Ort aufbewahren. Von Zündquellen fernhalten - Nicht rauchen. Maßnahmen gegen elektrostatische Aufladung treffen. Schützen gegen: Hitze. UV-Einstrahlung/Sonnenlicht.

Fire prevention

Maßnahmen gegen elektrostatische Aufladung treffen.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
flüssig
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
rotbraun
Colour Intensity
---
Form
---
Odor
Kohlenwasserstoffe, aromatisch.
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
148-151 °C (2-Methoxy-1-methylethylacetat)
Flash Point
46.5-48.0 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,02-1,10 g/cm³ (bei 25 °C)
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
unlöslich
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
5-35 mPa·s (bei 25 °C)
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Avoid

UV-Einstrahlung/Sonnenlicht. Hitze. Maßnahmen gegen elektrostatische Aufladung treffen. Alle Zündquellen entfernen.

Incompatible

Oxidationsmittel.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Unter Beachtung der behördlichen Bestimmungen beseitigen.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1866
Shipping Name
RESIN SOLUTION
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Kennzeichnung: Xi - Reizend. R-Sätze: 10, 36. S-Sätze: 16, 24/25.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ma-N 1400 Negativ-Photoresist Serie?

The signal word is na: r-phrases.

What is the physical form of ma-N 1400 Negativ-Photoresist Serie?

ma-N 1400 Negativ-Photoresist Serie is a flüssig with rotbraun color. It has kohlenwasserstoffe, aromatisch. odor.