NextSDS Logo
Safety Data Sheet DE

Interflon Grease MP1

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Interflon Grease MP1

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrielle Verwendung

Manufacturers & Suppliers

Interflon BV logo

Interflon BV

manufacturer

Belder 47, 4704 RK Roosendaal, Niederlande

+31 (0)165 553911

http://www.Interflon.com

Emergency Contacts

Emergency Contact

+31 (0)165 55 39 11

Monday to Friday from 8:30am to 17:00pm

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Gemisch aus Mineralölen, Verdicker, Additiven und MicPol®

Chemical Name CAS Number Concentration Hazardous
Dilithium azelate EC: 254-184-4 38900-29-7 3 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Bei unregelmäßiger Atmung oder Atemstillstand sofort ärztlichen Beistand suchen und Erste-Hilfe-Maßnahmen einleiten. Für Frischluft sorgen.

Skin contact

Bei Hautreizung oder -ausschlag: ärztlichen Rat einholen/ärztliche Hilfe hinzuziehen.

Eye contact

Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter ausspülen. Einige Minuten lang behutsam mit Wasser ausspülen.

Ingestion

Mund mit Wasser ausspülen (nur wenn Verunfallter bei Bewusstsein ist). KEIN Erbrechen herbeiführen. Bei Unwohlsein ärztlichen Rat einholen/ärztliche Hilfe hinzuziehen.

Immediate Medical Attention

Bei Unfall oder Unwohlsein sofort Arzt hinzuziehen (wenn möglich, dieses Etikett vorzeigen). Bei unregelmäßiger Atmung oder Atemstillstand sofort ärztlichen Beistand suchen und Erste-Hilfe-Maßnahmen einleiten.

Medical Treatment

keine

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Sprühwasser, Wassernebel, Feuerlöschpulver, Kohlendioxid (CO2), Alkoholbeständiger Schaum

Unsuitable media

Wasser im Vollstrahl

Specific hazards

Kann beim Verbrennen giftigen Kohlenmonoxidrauch erzeugen.

Instructions

Löschmaßnahmen auf die Umgebung abstimmen. Brandbekämpfung mit üblichen Vorsichtsmaßnahmen aus angemessener Entfernung.

Firefighter Protection

Geeignetes Atemschutzgerät benutzen.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Personen in Sicherheit bringen. Besondere Rutschgefahr durch auslaufendes/verschüttetes Produkt.

Environmental

nicht erforderlich

Cleanup methods

Mit saugfähigem Material (z.B. Lappen, Vlies) aufwischen.

Materials: Sägemehl, Kieselgur (Diatomit), Sand, Universalbinder

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Nach Gebrauch die Hände waschen. Bei der Arbeit nicht essen und trinken.

Storage

Gemäß lokalen/regionalen/nationalen/internationalen Vorschriften aufbewahren. Behälter dicht geschlossen an einem gut gelüfteten Ort aufbewahren. Kühl aufbewahren.

Hygiene

Nach Gebrauch die Hände waschen. Bei der Arbeit nicht essen und trinken.

Fire prevention

Kühl aufbewahren.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Nicht erforderlich.

Eyes

Zum Schutz gegen Flüssigkeitsspritzer Schutzbrille tragen.

Respiratory

Nicht erforderlich.

Skin/Body

Erholungsphasen zur Regeneration der Haut einlegen. Vorbeugender Hautschutz (Schutzcremes/Salben) wird empfohlen. Nach Gebrauch Hände gründlich waschen.

Environmental

Zur Vermeidung einer Kontamination der Umwelt geeigneten Behälter verwenden. Das Eindringen in die Kanalisation oder in Oberflächen- und Grundwasser verhindern.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
flüssig (Paste)
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
braun
Colour Intensity
---
Form
---
Odor
Wie Öl
Odor Threshold
---
Ph
nicht bestimmt
Melting Point
nicht bestimmt
Boiling Point
nicht bestimmt
Flash Point
nicht anwendbar
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
<0,1 hPa bei 20 °C
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,92 g/cm³ bei 20 °C
Flammability
nicht brennbar
Upper Explosive Limit
nicht brennbar
Lower Explosive Limit
nicht brennbar
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
nicht relevant
Solubility
leicht löslich
Partition Coefficient
nicht relevant
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
nicht relevant
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Das Material ist unter normalen Umgebungsbedingungen und unter den bei Lagerung und Handhabung zu erwartenden Temperatur- und Druckbedingungen stabil.

Reactivity

Bezüglich Unverträglichkeiten: siehe unten "Zu vermeidende Bedingungen" und "Unverträgliche Materialien".

Hazardous reactions

Es sind keine gefährlichen Reaktionen bekannt.

Avoid

Es sind keine speziell zu vermeidenden Bedingungen bekannt.

Incompatible

Oxidationsmittel, Starkes Oxidationsmittel

Decomposition

Gefährliche Verbrennungsprodukte: siehe Abschnitt 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxizität

Gemäß 1272/2008/EG: Ist nicht als gewässergefährdend einzustufen. Verordnung über Anlagen zum Umgang mit wassergefährdenden Stoffen (AwSV): WGK 1, schwach wassergefährdend (Deutschland)

12.2 Persistenz und Abbaubarkeit

Es sind keine Daten verfügbar.

12.3 Bioakkumulationspotenzial

Es sind keine Daten verfügbar.

12.4 Mobilität im Boden

Es sind keine Daten verfügbar.

12.5 Ergebnisse der PBT- und vPvB-Beurteilung

Dieses Gemisch enthält keine Stoffe, die als PBT- oder vPvB-Stoff beurteilt werden.

Das Gemisch enthält keine Stoffe, die als PBT- oder vPvB-Stoff beurteilt werden.

12.6 Endokrinschädliche Eigenschaften

Enthält keinen endokrinen Disruptor (ED) in einer Konzentration von ≥ 0,1%.

Das Produkt enthält keine endokrinen Disruptoren in einer Konzentration von ≥ 0,1%.

12.7 Andere schädliche Wirkungen

Es sind keine Daten verfügbar.

Es sind keine Daten verfügbar.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dieses Erzeugnis ist als gefährlicher Abfall zu entsorgen und darf nicht zusammen mit Ihrem normalen Haushaltsmüll entsorgt werden. Dieses Produkt und seinen Behälter der Problemabfallentsorgung zuführen.

Waste Codes

20 01 26* Öle und Fette mit Ausnahme derjenigen, die unter 20 01 25 fallen EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Interflon Grease MP1

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Interflon Grease MP1?

The signal word is no signal word.

What is the physical form of Interflon Grease MP1?

Interflon Grease MP1 is a flüssig (paste) with braun color. It has wie öl odor.

What is the solubility of Interflon Grease MP1?

leicht löslich

What is Interflon Grease MP1 used for?

Industrielle Verwendung

What is the melting point of Interflon Grease MP1?

The melting point is nicht bestimmt and the boiling point is nicht bestimmt.