Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
European Community number - used for regulatory compliance in EU/EEA
Uses Information
Overview
Cesium iodide (CAS: 7789-17-5 ) is a various forms (powder/flake/crystalline/beads, etc.) substance commonly used su24 scientific research and development.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation.
Precautionary Statements
- P261: Avoid breathing dust/fume/gas/mist/vapors/spray
- P280: Wear protective gloves / eye protection / face protection.
- P305+P351+P338: If in eyes: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
- P405: Store locked up.
- P501: Dispose of contents/container in accordance with local/regional/national/international regulations.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.
manufacturer
30 Bond Street, Ward Hill, MA 01835-8099
US
800-343-0660
800-322-4757
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
800-343-0660
During normal business hours (Monday-Friday, 8am-7pm EST)
After normal business hours, call Carechem
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
substanceGeneral Composition
Substances
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Caesium iodide EC: 232-145-2 | 7789-17-5 | 100% | β Non-hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
π« Inhalation Exposure
Supply fresh air. If required, provide artificial respiration. Keep patient warm.
ποΈ Skin Contact
Immediately wash with water and soap and rinse thoroughly.
Symptoms:
Causes skin irritation.
ποΈ Eye Contact
Rinse opened eye for several minutes under running water. Then consult a doctor.
Symptoms:
Causes serious eye irritation.
π½οΈ Ingestion/Swallowing
Seek medical treatment.
Symptoms:
Harmful if swallowed.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
π Engineering Controls
Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.
π§€ Hand Protection
Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Nitrile rubber, NBR. Penetration time of glove material (in minutes) Not determined.
ποΈ Eye Protection
Safety glasses with side shields / NIOSH (US) or EN 166(EU).
π· Respiratory Protection
Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with type N95 (USA) or PE (EN 143) cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards.
π¦Ί Skin/Body Protection
Protective work clothing.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
π¦ Proper Shipping Name
Not applicable
β οΈ Transport Hazard Class
Not applicable
π Packing Group
Not applicable
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Cesium iodide?
The signal word for this substance is "warning".
What is Cesium iodide used for?
SU24 Scientific research and development
What are the hazard statements for Cesium iodide?
This substance has 5 hazard statements: H302: Harmful if swallowed. H315: Causes skin irritation. H317: May cause an allergic skin reaction. H319: Causes serious eye irritation. H335: May cause respiratory irritation.
What is the melting point of Cesium iodide?
The melting point is 626 β (1159 ΒΊF) and the boiling point is 1280 β (2336 ΒΊF).