NextSDS Logo
Safety Data Sheet EN

Iron(III) oxide, Puratronic®

CAS 1309-37-1
EC 215-168-2

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Iron(III) oxide, Puratronic®
Product Code
10716
Chemical Name
Iron(III) oxide

Regulatory Identifiers

CAS Number
1309-37-1 Check regulations →
EC Number
215-168-2 Check regulations →

Identified Uses

SU24 Scientific research and development

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street Ward Hill, MA 01835-8099

www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Chemical characterization: Substances

Chemical Name CAS Number Concentration Hazardous
N/A --- 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Nitrile rubber, NBR. Penetration time of glove material (in minutes) 480. Glove thickness: 0.11 mm.

Eyes

Safety glasses with side shields / NIOSH (US) or EN 166(EU).

Respiratory

Use suitable respirator when high concentrations are present. Use suitable respiratory protective device in case of insufficient ventilation. Recommended filter device for short term use: Use a respirator with type N95 (USA) or PE (EN 143) cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Relative Evaporation Rate
---
Form
---
Colour
---
Melting Point
1565 ℃ (2849 °F)
Odor Threshold
Not determined.
Flash Point
---
Cloud Point
---
Solubility In Water
Insoluble
Colour Intensity
---
Appearance
Powder
Auto Ignition Temperature
Not determined.
Relative Density
Not determined.
Ph
Not applicable.
Boiling Point
Not determined
Dynamic Viscosity
Not applicable.
Crystallisation Point
---
Explosive Limits
---
Density
5.24 g/cm3 (43.728 lbs/gal)
Freezing Point
---
Vapor Pressure
Not applicable.
Kinematic Viscosity
Not applicable.
Physical State Data
---
Upper Explosive Limit
Not determined
Solubility
Insoluble
Metal Corrosion
---
Odor
Odorless
Molecular Weight
---
Physical State
---
Softening Point
---
State Under Standard Conditions
---
Vapor Density
Not applicable.
Flammability
Not determined.
Lower Explosive Limit
Not determined
Decomposition Temperature
Not determined.
Solidification Point
---
Evaporation Rate
Not applicable.
Voc Content
---
Partition Coefficient
Not determined.
Properties Status
---
Solubility In Fat
---
Bulk Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Iron(III) oxide, Puratronic®?

The signal word is no signal word.

What is the solubility of Iron(III) oxide, Puratronic®?

Insoluble

What is Iron(III) oxide, Puratronic® used for?

SU24 Scientific research and development

What is the melting point of Iron(III) oxide, Puratronic®?

The melting point is 1565 ℃ (2849 °F) and the boiling point is Not determined.

Compliance Scanner

Scan your compliance