NextSDS Logo
Di

Diazinon

DANGER liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Diazinon
Product Code
45428

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory chemicals, Synthesis of substances

Overview

Diazinon is a form: liquid colour: beige substance commonly used laboratory chemicals, synthesis of substances.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 4 H302
Carc. Category 1B H350
Aquatic Acute Category 1 H400
Aquatic Chronic Category 1 H410

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H302: Harmful if swallowed.
  • H350: May cause cancer.
  • H410: Very toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P201: Obtain special instructions before use.
  • P202: Do not handle until all safety precautions have been read and understood.
  • P264: Wash skin thoroughly after handling.
  • P270: Do not eat, drink or smoke when using this product.
  • P273: Avoid release to the environment.
  • P280: Wear protective gloves/ protective clothing/ eye protection/ face protection.
  • IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. Rinse mouth.
  • P308+P313: IF exposed or concerned: Get medical advice/ attention.
  • P391: Collect spillage.
  • P405: Store locked up.
  • P501: Dispose of contents/ container to an approved waste disposal plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma-Aldrich

manufacturer

๐Ÿ“

3050 Spruce Street, SAINT LOUIS MO 63103, USA

๐ŸŒ

US

๐Ÿ“ž

+1 800-325-5832

๐Ÿ“ 

+1 800-325-5052

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

+1-703-527-3887

๐ŸŒ

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Diazinon
EC: 206-373-8
333-41-5 100% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

๐Ÿ–๏ธ Skin Contact

Wash off with soap and plenty of water. Consult a physician.

๐Ÿ‘๏ธ Eye Contact

Flush eyes with water as a precaution.

๐Ÿฝ๏ธ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

๐Ÿ”ฅ Fire Fighting Instructions

Wear self-contained breathing apparatus for firefighting if necessary.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐ŸŒ Environmental Precautions

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

๐Ÿงน Cleanup Methods

Keep in suitable, closed containers for disposal.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Form: liquid Colour: beige
๐ŸŽจ Colour
beige
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
No data available
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
No data available
๐ŸงŠ Melting Point
No data available
Critical Property
๐Ÿ’จ Boiling Point
No data available
Critical Property
๐Ÿ”ฅ Flash Point
104.4 โ„ƒ (219.9 ยบF) - closed cup
Critical Property
๐Ÿ“Š Freezing Point
No data available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available
๐Ÿ’จ Vapor Pressure
< 0.001 hPa (< 0.001 mmHg) at 25 โ„ƒ (77 ยบF)
๐Ÿ“Š Vapor Density
No data available
๐Ÿ“Š Relative Density
1.116 - 1.119 g/cm3 at 20 โ„ƒ (68 ยฐF)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
No data available
๐Ÿ“Š Upper Explosive Limit
No data available
๐Ÿ“Š Lower Explosive Limit
No data available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
No data available
๐Ÿ“Š Partition Coefficient
log Pow: 3.3
๐Ÿ“Š Solubility In Water
No data available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Avoid contact with skin and eyes.

โ€ข Avoid inhalation of vapour or mist.

๐Ÿช Storage Conditions

โ€ข Keep container tightly closed in a dry and well-ventilated place.

โ€ข Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

๐Ÿงค Hand Protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. Full contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Material tested: Dermatrilยฎ (KCL 740 / Aldrich Z677272, Size M) Splash contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Material tested: Dermatrilยฎ (KCL 740 / Aldrich Z677272, Size M) data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail [email protected], test method: EN374 If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

๐Ÿ‘๏ธ Eye Protection

Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

๐Ÿ˜ท Respiratory Protection

Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

๐Ÿฆบ Skin/Body Protection

Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

๐ŸŒ Environmental Exposure Controls

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

Stable under recommended storage conditions.

๐Ÿงช Incompatible Materials

Strong oxidizing agents

๐Ÿ’จ Hazardous Decomposition Products

Hazardous decomposition products formed under fire conditions. - Carbon oxides, Nitrogen oxides (NOx), Sulphur oxides, Oxides of phosphorus. Other decomposition products - No data available.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Toxicity

Toxicity to fish mortality LOEC - Pimephales promelas (fathead minnow) - 0.316 mg/l - 7.0 d LC50 - Salmo salar (Atlantic salmon) - 3.2 mg/l - 96.0 h mortality LOEC - Daphnia (water flea) - 0.001 mg/l - 48 h Toxicity to daphnia and other aquatic invertebrates mortality NOEC - Daphnia magna (Water flea) - 0.001 mg/l - 48 h EC50 - Daphnia magna (Water flea) - 0.7 ยตg/l - 48 h

๐ŸŒฑ Persistence and degradability

No data available

๐ŸŒฑ Bioaccumulative potential

Bioaccumulation Cyprinus carpio (Carp) - 14 d - 18 ยตg/l Bioconcentration factor (BCF): 120

๐ŸŒฑ Mobility in soil

No data available

๐ŸŒฑ Results of PBT and vPvB assessment

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

๐ŸŒฑ Other adverse effects

An environmental hazard cannot be excluded in the event of unprofessional handling or disposal. Very toxic to aquatic life with long lasting effects.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

โ™ป๏ธ Waste Treatment Methods

Offer surplus and non-recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material. Dissolve or mix the material with a combustible solvent and burn in a chemical incinerator equipped with an afterburner and scrubber.

๐Ÿ—‚๏ธ Product Disposal Recommendations

Dispose of as unused product.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

2810

๐Ÿ“ฆ Proper Shipping Name

Toxic, liquids, organic, n.o.s. (Diazinon)

โš ๏ธ Transport Hazard Class

6.1

๐Ÿ“‹ Packing Group

III

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

๐Ÿ“‹ Regulatory Summary

No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.

โŒ Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

โ„น๏ธ Additional Regulatory Information

The following components are subject to reporting levels established by SARA Title III, Section 313: Diazinon (CAS-No. 333-41-5, Revision Date: 2007-07-01). SARA 311/312 Hazards: Acute Health Hazard, Chronic Health Hazard. This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Diazinon?

The signal word for this substance is "danger".

What is the physical form of Diazinon?

Diazinon is a liquid appearing as form: liquid colour: beige with beige color. It has no data available odor.

What is the solubility of Diazinon?

No data available

What is Diazinon used for?

Laboratory chemicals, Synthesis of substances

What are the hazard statements for Diazinon?

This substance has 3 hazard statements: H302: Harmful if swallowed. H350: May cause cancer. H410: Very toxic to aquatic life with long lasting effects.

What is the melting point of Diazinon?

The melting point is No data available and the boiling point is No data available.