NextSDS Logo
Bi

Bis(2-ethylhexyl) sebacate

NO SIGNAL WORD Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Bis(2-ethylhexyl) sebacate
Product Code
A16049
Chemical Name
Bis(2-ethylhexyl) sebacate

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
SU24 Scientific research and development

Overview

Bis(2-ethylhexyl) sebacate (CAS: 122-62-3 ) is a not determined substance commonly used su24 scientific research and development.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. company logo - Safety Data Sheet supplier organization

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

📍

30 Bond Street, Ward Hill, MA 01835-8099

🌍

US

📞

800-343-0660

📠

800-322-4757

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

800-343-0660

🕒

Monday-Friday, 8am-7pm EST

💡

After normal business hours, call Carechem

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Substances

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Bis(2-ethylhexyl) sebacate
EC: 204-558-8
122-62-3 100% ✓ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

🖐️ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

👁️ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

🍽️ Ingestion/Swallowing

Seek medical treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Kinematic Viscosity
Not determined.
📊 Cloud Point
Not available
📊 Solubility In Water
Not determined
📊 Colour Intensity
Not available
📊 Relative Density
Not determined.
📊 Softening Point
Not available
📊 Auto Ignition Temperature
Not determined.
💨 Boiling Point
211-213 °C (412-415 °F) (1mm)
Critical Property
📊 Lower Explosive Limit
Not determined
📊 State Under Standard Conditions
Not available
📊 Bulk Density
Not available
📊 Upper Explosive Limit
Not determined
📊 Odor Threshold
Not determined.
📊 Solubility In Fat
Not available
🧪 Physical State
Liquid
Critical Property
📊 Freezing Point
Not available
📊 Partition Coefficient
Not determined.
💧 Solubility
Not determined
📊 Crystallisation Point
Not available
📊 Form
Liquid
🧊 Melting Point
Not determined
Critical Property
💨 Vapor Pressure
Not determined
📊 Relative Evaporation Rate
Not available
📊 Decomposition Temperature
Not determined.
🔥 Flash Point
>110 °℃ (>230 °F)
Critical Property
🎨 Colour
Not available
📊 Physical State Data
liquid
👁️ Appearance
Not determined
📊 Properties Status
Not available
🔥 Flammability
Not determined.
📊 Molecular Weight
Not available
📊 Dynamic Viscosity
Not determined.
🧪 Ph
Not determined.
⚖️ Density
0.914 g/cm3 (7.627 lbs/gal)
Critical Property
📊 Explosive Limits
Not available
💨 Evaporation Rate
Not determined.
📊 Vapor Density
Not determined.
📊 Metal Corrosion
Not available
📊 Voc Content
Not available
👃 Odor
Not determined
📊 Solidification Point
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

🧤 Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Nitrile rubber, NBR.

👁️ Eye Protection

Safety glasses with side shields / NIOSH (US) or EN 166(EU).

😷 Respiratory Protection

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with multi-purpose combination (US) or type ABEK (EN 14387) as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

🦺 Skin/Body Protection

Protective work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

📦 Proper Shipping Name

Not applicable

⚠️ Transport Hazard Class

Not applicable

📋 Packing Group

Not applicable

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Bis(2-ethylhexyl) sebacate?

The signal word for this substance is "no signal word".

What is the physical form of Bis(2-ethylhexyl) sebacate?

Bis(2-ethylhexyl) sebacate is a liquid appearing as not determined . It has not determined odor.

What is the solubility of Bis(2-ethylhexyl) sebacate?

Not determined

What is Bis(2-ethylhexyl) sebacate used for?

SU24 Scientific research and development

What is the melting point of Bis(2-ethylhexyl) sebacate?

The melting point is Not determined and the boiling point is 211-213 °C (412-415 °F) (1mm).